DeVillbiss Air Power Company MG7-OFTWIN Routine Maintenance Schedule, Service Instructions

Page 10

MAINTENANCE

UNIT CYCLES AUTOMATICALLY WHEN POWER IS ON. WHEN DOING MAINTENANCE, YOU MAY BE EXPOSED TO VOLTAGESOURCES,COMPRESSED AIR ORMOVING PARTS. PERSONALINJURIESCAN OCCUR. BEFOREPERFORM- ING ANY MAINTENANCE OR REPAIR, DISCONNECT POWER SOURCE FROM THE COMPRESSOR AND BLEED OFF ALL AIR PRESSURE.

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE DONE BY

QUALIFIED SERVICE PERSONNEL.

To ensure efficient operation and longer life of the air compressor outfit, a routine maintenance schedule should be prepared and followed. The following routine maintenance schedule is geared to an outfit in a normal working environment operating on a daily basis. If necessary, the schedule should be modified to suit the conditions under which your compressor is used. The modifications will depend upon the hours of operation and the working environment. Compressor outfits in an extremely dirty and/or hostile environment will require a greater frequency of all maintenance checks.

ROUTINE MAINTENANCE SCHEDULE

Daily:

1.Drain water from the air tank, any moisture separators or transformers.

2.Check for any unusual noise and/or vibration.

3.Manually check safety valve to make sure of proper opera- tion.

4.Inspect air filter, replace if necessary.

5.Inspect air lines and fittings for leaks; correct as necessary.

Each Year of Operation or if a Problem is Suspected:

Check condition of air compressor pump intake and exhaust valves. Replace if damaged or worn out.

SERVICE INSTRUCTIONS

Air Filter - Inspection and Replacement

Keep the air filter clean at all times. Do not operate the compressor with the air filter removed.

A dirty air filter will not allow the compressor to operate at full capacity. Before you use the compressor, check the air filter to be sure it is clean.

If it is dirty, simply pull it out. You may wash it with a mild detergent and warm water, or replace it.

Hot surfaces. Risk of burn. Compressor heads are exposed when filter cover is removed. Allow compressor to cool prior to servicing.

Filter

Safety Valve - Inspection

IF THE SAFETY VALVE DOES NOT WORK PROP- ERLY, OVER-PRESSURIZATION MAY OCCUR, CAUSING AIR TANK RUPTURE OR AN EXPLO- SION. DAILY PULL THE RING ON THE SAFETY VALVE TO MAKE SURE THAT THE SAFETY VALVE OPERATES FREELY. IF THE VALVE IS STUCK OR DOES NOT OPERATE SMOOTHLY, IT MUST BE REPLACED WITH THE SAME TYPE OF VALVE.

Motor

The motor has an automatic reset thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. The compressor will automatically restart after the motor cools.

If the overload protector shuts the motor off frequently, check for a possible voltage problem. Low voltage can also be suspected when:

1.The motor does not get up to full power or speed.

2.Fuses blow out when starting the motor; lights dim and remain dim when motor is started and/or is running.

Units With External Brass Check Valve Replacement

1.Release all air pressure from air tank and disconnect power from outfit.

2.Remove shroud.

3.Loosen the top and bottom nuts and remove the outlet tube.

4.Remove the pressure release tube and fitting.

5.Unscrew the check valve (turn counterclockwise) using a socket wrench.

6.Check that the valve disc moves freely inside the check valve and that the spring holds the disc in the upper, closed position. The check valve may be cleaned with a strong solvent.

7.Apply sealant to the check valve threads. Reinstall the check valve (turn clockwise).

8.Replace the pressure release tube and fitting.

9.Replace the outlet tube and tighten top and bottom nuts.

10.Replace the shroud.

10 — ENG

Image 10
Contents Permanently Lubricated Twin Cylinder AIR Compressors Limited Warranty ONE Year from Date of Purchase Important Safety Instructions Whatcanhappen Cont’dGeneral Information GlossaryDuty Cycle ON-RECEIPT InspectionAssembly for Portable Compressors Tools Needed for AssemblyDescription of Operation Lubrication and Oil Installation and BREAK-IN ProceduresLocation of the Air Compressor Extension CordsPiping Break-inProceduresVoltage and Circuit Protection Grounding Instruction Portable UnitsOperating Procedures Daily Start-Up ChecklistRoutine Maintenance Schedule MaintenanceService Instructions Storage Troubleshooting Guide Problem Cause CorrectionTripped Cally reset Service Notes Notas DE Servicio Service Notes Notas DE Servicio Service Notes