DeVillbiss Air Power Company MG7-OFTWIN warranty Whatcanhappen, Cont’d

Page 4

 

 

HAZARD

WHATCANHAPPEN

 

 

HOW TO PREVENT IT

 

 

 

 

 

 

 

 

 

RISK OF

REPAIRS ATTEMPTED BY UNQUALIFIED PER-

ANY ELECTRICAL WIRING OR REPAIRS RE-

 

ELECTRICAL SHOCK

SONNEL CAN RESULT IN SERIOUS INJURY OR

QUIRED ON THIS PRODUCT SHOULD BE

 

DEATH BY ELECTROCUTION.

 

PERFORMED BY AUTHORIZED SERVICE CEN-

 

 

(cont’d)

 

 

 

TER PERSONNEL IN ACCORDANCE WITH

 

 

 

 

ELECTRICAL

GROUNDING:

FAILURE TO

NATIONAL AND LOCAL ELECTRICAL CODES.

 

 

 

 

MAKE CERTAIN THAT THE ELECTRICAL

 

 

 

 

PROVIDE ADEQUATE GROUNDING TO THIS

CIRCUIT TO WHICH THE COMPRESSOR IS

 

 

 

 

PRODUCT COULD RESULT IN SERIOUS

CONNECTED PROVIDES PROPER ELECTRICAL

 

 

 

 

INJURY OR DEATH FROM ELECTROCUTION.

GROUNDING, CORRECT VOLTAGE AND AD-

 

 

 

 

SEE GROUNDING INSTRUCTIONS.

EQUATE FUSE PROTECTION.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RISK FROM

THE COMPRESSED AIR STREAM CAN CAUSE

ALWAYS WEAR ANSI Z87.1 APPROVED SAFETY

 

 

SOFT TISSUE DAMAGE TO EXPOSED SKIN AND

GLASSES WITH SIDE SHIELDS WHEN USING

 

FLYING OBJECTS

CAN PROPEL DIRT, CHIPS, LOOSE PARTICLES

THE COMPRESSOR.

 

 

 

 

 

 

 

AND SMALL OBJECTS AT HIGH SPEED,

 

 

 

 

 

 

 

 

 

 

 

RESULTING IN PROPERTY DAMAGE OR PER-

NEVER POINT ANY NOZZLE OR SPRAYER

 

 

 

 

 

 

 

 

SONAL INJURY.

 

TOWARD ANY PART OF THE BODY OR AT

 

 

 

 

 

 

 

OTHER PEOPLE OR ANIMALS.

 

 

 

 

 

 

 

 

 

ALWAYS TURN THE COMPRESSOR OFF AND

 

 

 

 

 

 

 

BLEED PRESSURE FROM THE AIR HOSE AND

 

 

 

 

 

 

 

TANK

BEFORE

ATTEMPTING

MAINTENANCE,

 

 

 

 

 

 

 

ATTACHING TOOLS OR ACCESSORIES.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RISK TO BREATHING

THE COMPRESSED AIR FROM

YOUR COM-

NEVER INHALE AIR FROM THE COMPRESSOR

 

 

 

 

PRESSOR IS NOT SAFE FOR BREATHING! THE

 

 

 

 

EITHER

 

DIRECTLY OR

FROM

A BREATHING

 

 

 

 

AIR STREAM MAY CONTAIN CARBON MONOX-

 

 

 

 

 

DEVICE CONNECTED TO THE COMPRESSOR.

 

 

 

 

IDE, TOXIC VAPORS OR SOLID PARTICLES.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPRAYED MATERIALS SUCH AS PAINT, PAINT

WORK

IN AN

AREA

WITH

GOOD CROSS-

 

 

 

 

VENTILATION. READ AND FOLLOW THE SAFETY

 

 

 

 

SOLVENTS,

PAINT REMOVER,

INSECTICIDES,

 

 

 

 

INSTRUCTIONS PROVIDED ON THE LABEL OR

 

 

 

 

WEED KILLERS, ETC.. CONTAIN HARMFUL

 

 

 

 

SAFETY

DATA

SHEETS

FOR

THE MATERIAL

 

 

 

 

VAPORS AND POISONS.

 

 

 

 

 

 

YOU ARE SPRAYING.

USE A NIOSH/MSHA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APPROVED RESPIRATOR DESIGNED FOR USE

 

 

 

 

 

 

 

WITH

 

YOUR

SPECIFIC

APPLICATION.

 

 

 

 

 

 

 

RISK OF FALLING

A PORTABLE COMPRESSOR CAN FALL FROM

ALWAYS OPERATE COMPRESSOR IN A STABLE

 

 

 

 

A TABLE, WORKBENCH OR ROOF CAUSING

SECURE POSITION TO PREVENT ACCIDENTAL

 

 

 

 

DAMAGE TO THE COMPRESSOR WHICH

MOVEMENT OF THE UNIT. NEVER OPERATE

 

 

 

 

COULD RESULT IN SERIOUS INJURY.

COMPRESSOR ON A ROOF OR OTHER

 

 

 

 

 

 

 

ELEVATED POSITION. USE ADDITIONAL AIR

 

 

 

 

 

 

 

HOSE TO REACH HIGH LOCATIONS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RISK FROM

THE COMPRESSOR CYCLES AUTOMATICALLY

ALWAYS TURN OFF THE COMPRESSOR, BLEED

 

MOVING PARTS

WHEN THE PRESSURE SWITCH IS IN THE ON/

PRESSURE FROM THE AIR HOSE AND TANK,

 

AND UNPLUG

FROM

ELECTRICAL OUTLET

 

 

 

 

AUTO POSITION.

 

 

 

 

 

 

BEFORE

PERFORMING MAINTENANCE

OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ATTACHING TOOLS AND ACCESSORIES.

 

 

 

 

 

MOVING PARTS CAN CAUSE SERIOUS INJURY

DO NOT REMOVE THE PROTECTIVE COVERS

 

 

 

 

OR DAMAGE IF THEY COME INTO CONTACT

FROM THIS PRODUCT.

NEVER OPERATE THE

 

 

 

 

WITH YOU OR YOUR CLOTHING.

 

COMPRESSOR WITH GUARDS OR COVERS

 

 

 

 

ATTEMPTING TO OPERATE OR REPAIR

WHICH ARE DAMAGED OR REMOVED.

 

 

 

 

 

 

 

 

 

 

ANY REPAIRS REQUIRED ON THIS PRODUCT

 

 

 

 

COMPRESSOR WITH PROTECTIVE SHROUDS

SHOULD BE PERFORMED BY AUTHORIZED

 

 

 

 

REMOVED CAN EXPOSE YOU TO MOVING

SERVICE CENTER PERSONNEL.

 

 

 

 

 

PARTS AND ELECTRICAL SHOCK.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RISK OF BURNS

TOUCHING EXPOSED METAL SUCH AS THE

NEVER TOUCH ANY EXPOSED METAL PARTS

 

COMPRESSOR HEAD OR OUTLET TUBE CAN

ON COMPRESSOR DURING OR IMMEDIATELY

 

 

 

 

 

 

 

 

RESULT IN SERIOUS BURNS.

 

AFTER

 

OPERATION.

COMPRESSOR

WILL

 

 

 

 

 

 

 

 

 

 

 

 

 

REMAIN HOT FOR SEVERAL MINUTES AFTER

 

 

 

 

 

 

 

OPERATION.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TMPCPOL — 5/1/97

4 — ENG

Image 4
Contents Permanently Lubricated Twin Cylinder AIR Compressors Limited Warranty ONE Year from Date of Purchase Important Safety Instructions Whatcanhappen Cont’dGlossary Duty CycleGeneral Information ON-RECEIPT InspectionAssembly for Portable Compressors Tools Needed for AssemblyDescription of Operation Installation and BREAK-IN Procedures Location of the Air CompressorLubrication and Oil Extension CordsBreak-inProcedures Voltage and Circuit ProtectionPiping Grounding Instruction Portable UnitsOperating Procedures Daily Start-Up ChecklistRoutine Maintenance Schedule MaintenanceService Instructions Storage Troubleshooting Guide Problem Cause CorrectionTripped Cally reset Service Notes Notas DE Servicio Service Notes Notas DE Servicio Service Notes