CONSTRUCTION

Standard: Transducer is all stainless steel construction with silicone fill fluid, 316L diaphragms and glass-filled PTFE o-rings. Coupling is A360 Aluminum with urethane coating.

Optional: Transducer includes Hastelloy C-276 wetted parts (construction is NACE compliant per MR0103 and ISO15156/MR0175), inert fill fluid. Coupling is available in 316 stainless steel (CF8M).

MOUNTING

Factory-installed on enclosure of FB103, FB107E, and FB503. See respective specification sheet for unit mounting options.

CONNECTIONS

Process: 1/4-18 NPT on 2-1/8 inch centers (on coplanar flange).

APPROVALS

Same as the FloBoss unit in which it is installed.

Image 3
Contents Coupling Sensor Body Coplanar Flange 5DVS205January Two versions of the DVS transmitter are availableDifferential Pressure Input PowerWeight DimensionsProcess 1/4-18 NPT on 2-1/8 inch centers on coplanar flange ConstructionMounting ConnectionsEmerson Process Management Remote Automation Solutions