RIDGID 140276004 manual Operation

Page 4

OPERATION

APPLICATIONS

You may use this tool for the following purposes:

Charging 9.6 Volt, 12 Volt, 14.4 Volt, and 18 Volt RIDGID slide batteries

CAUTION:

If at any point during the charging process none of the LEDs are lit, remove the battery pack from the charger to avoid damaging the product. DO NOT insert another battery. Return the charger and battery to your nearest service center for service or replacement.

CHARGING THE BATTERY PACK

The battery pack for this tool has been shipped in a low charge condition to prevent possible problems. Therefore, you should charge it until the light on front of charger changes from flashing green to continuous green.

NOTE: Batteries will not reach full charge the first time they are charged. Allow several cycles (operation followed by recharging) for them to become fully charged. This is normal for nickel-cadmium batteries.

TO CHARGE

Charge the battery pack only with the charger provided. Make sure the power supply is normal household voltage,

120 volts, 60 Hz, AC only.

Connect the charger to a power supply.

Attach the battery pack to the charger by aligning the raised ribs on the battery pack with the grooves in the charger, then slide the battery pack onto the charger.

See Figure 2.

The battery pack will become slightly warm to the touch while charging. This is normal and does not indicate a problem.

Do not place the charger in an area of extreme heat or cold. It will work best at normal room temperature.

For average charge times, refer to the chart on the following page.

When the batteries become fully charged, unplug the charger from the power supply and remove the battery pack.

CHARGING A HOT BATTERY PACK

When using the tool continuously, the battery pack will become hot. Because the dual port charger is fan-cooled, a hot battery pack may be placed directly onto the charger port. When placed on the charger, a hot battery pack will cool for 20 minutes or less before attempting to recharge.

If the battery pack is above normal temperature range, the red LED will begin flashing and the green LED will be off. When the battery pack cools down to approximately 104°F (40°C), the charger will automatically begin fast charge mode.

CHARGER SHOWN WITH 18 VOLT BATTERY PACK

Fig. 2

NOTE: Refer to CHARGING THE BATTERY PACK for normal recharging of batteries. If the charger does not charge your battery pack under normal circumstances, return both the battery pack and charger to your nearest repair center for electrical check. For the location of your nearest repair center, please call 1-866-539-1710.

CHARGING A COOL BATTERY PACK

If the battery pack is below normal temperature range, the red LED will begin flashing and the green LED will be off. When the battery warms to a temperature of more than 41°F (5°C), the charger will automatically begin fast charge mode.

NOTE: Refer to CHARGING THE BATTERY PACK for normal recharging of batteries. If the charger does not charge your battery pack under normal circumstances, return both the battery pack and charger to your nearest repair center for electrical check. For the location of your nearest repair center, please call 1-866-539-1710.

USE THIS RIDGID BATTERY CHARGER ONLY WITH

THE BATTERY PACKS LISTED BELOW.

Part Number

Voltage

Part Number

Voltage

 

 

 

 

130252007

9.6

130254008

14.4

130252002

12

130252001

18

130254001

12

130252004

18

130252003

14.4

130254003

18

130254002

14.4

130254007

18

 

 

 

 

4

Image 4
Contents Dual Port Battery Charger OPERATOR’S ManualImportant Safety Instructions Important Safety InstructionsSymbols FeaturesOperation LED Battery RED Green Action Indicator Pack LED Function of ChargerMaintenance General MaintenanceKeeping the Charger Vents Clean Battery Pack Removal Preparation for RecyclingWarranty DAY Satisfaction Guarantee PolicyWhat is Covered Under the 3 Year Limited Service Warranty HOW to Obtain Service What is not CoveredCustomer Service Information