Remove Screws
Installing Light Bulb
WARNING: To reduce the risk of electrical shock, unplug the tool before installing light bulb.
1.Remove the amber colored lens cover by removing the two Phillips screws.
2.Install a light bulb (not larger than 60 watt) into the socket inside the head.
3.Replace the lens cover.
Adjusting the Table Square To Head
NOTE: The combination square must be “true”. See “Unpacking and Checking Contents” section for method.
1.Insert precision round steel rod or straight drill bit approximately 3” long into chuck and tighten.
2.With table raised to working height and locked on column, place combination square flat on table beside rod or bit.
3.If an adjustment is necessary, loosen the set screw under bevel lock with 3mm “L” wrench, then loosen the table bevel lock bolt with the 24mm hex box wrench (included). (This adjustment is located under the table).
4.Align the table square to the rotor bit by rotating table until the square and rod or bit are in line.
5.Retighten table bevel lock.
6.Retighten set screw.
Table
Set
Screw Table Bevel
Lock
Bevel Scale
NOTE: The bevel scale has been included to provide a quick method for beveling the table to approximate angles. If precise accuracy is necessary, a square, or other precision measuring tool should be used to position the table.
1.To use the bevel scale do the following.
a.Loosen set screw and table bevel lock (see step 3 above).
b.Move table so desired angle on bevel scale is straight across from zero line on pointer.
c.Retighten table bevel lock and set screw.
Table
Pointer
Scale
19