Installing The
Hanger Bracket
!WARNING
The fan must be hung with at least 7' of clearance from floor to blades (Figure 4).
7'
MIN.
Figure 4
FLOOR
!WARNING
The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”.
1.Unscrew (but do not remove) the two mounting screws in the outlet box (Figure 5). Position the hanger bracket on the outlet box so that the
| OUTLET BOX |
| LOOSEN TWO |
SCREWS (SUPPLIED | |
WITH OUTLET BOX) |
SLIDE THE HANGER
BRACKET ONTO
THE OUTLET BOX
SCREWS, THROUGH
THE
HANGER
BRACKET
Figure 5
!WARNING
To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
NOTE: The hanger bracket must be mounted flush with the ceiling in order for the ceiling cover to install properly. If necessary, use leveling washers (not supplied) between the outlet box and the hanger bracket.
2.Slide the hanger bracket onto the outlet box screws. Center the bracket over the outlet box and then securely tighten the screws (Figure 6).
!WARNING
Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, use leveling washers between the hanger bracket and the outlet box until the bracket is flush with the ceiling. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
| SECURELY |
| TIGHTEN |
HOOK | SCREWS |
| |
| HANGER BRACKET |
Figure 6
Hanging The Ceiling Fan
(Standard Method Using
Hanger Ball/Downrod)
1.Carefully lift the fan assembly and seat the hanger ball in the hanger bracket (Figure 7). The tab on the hanger bracket must seat in the groove in the hanger ball.
!WARNING
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
!WARNING
To avoid fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.
5