Contec CS2000-QD manual LED Functions, Operation Features Output Mode, Factory Settings

Page 11

Operation

LED Functions:

Yellow - comes on when label backing (web) is under the sensing area

Red - comes on when output is active - NPN sinking or PNP sourcing

Green - comes on when label over label backing is under the sensing area

Operation Features:

The CS2000 has 3 different operation features that can be changed to accommodate individual needs. They are Output Mode, Light/Dark Operation, and Contrast Setting.

Operation Features - Output Mode:

The CS2000 has 2 different output modes - Level Shift Output and Pulse Output. Level Shift Output is either on for the length of the web, or on for the length of the label, depending on the Light/Dark Operation setting. Pulse Output either comes on for 2 m.s. at the leading edge of a label, or goes off for 2 m.s. at the leading edge of a label, depending on the Light/Dark Operation setting. Refer to Program Mode (page 12) for more information.

Operation Features - Light/Dark Operation:

The CS2000 allows you the option of having the sensor's output active on the web (Light Operate), or having the sensor's output active on the label (Dark Operate). Light Operate is either on for the length of the web, or comes on for 2 m.s. at the leading edge of a label, depending on the Output Mode setting. Dark Operate is either on for the length of the label, or goes off for 2 m.s. at the leading edge of a label, depending on the Output Mode setting. Refer to Program Mode (page 12) for more information.

Operation Features - Contrast Setting:

The CS2000 comes with a Normal Contrast Setting and a Low Contrast Setting. Normal Contrast Setting should be fine for 99% of labels. But with labels that offer very little contrast between the web and the label, the Low Contrast Setting can be selected very easily. Refer to Program Mode (page 12) for more information. Adjustments to the label sensitivity should be made more frequently when the Low Contrast Setting is selected.

*Factory Settings:

 

Output Mode

Factory set to Level Shift

Light/Dark Operation

Factory set to Light

Contrast Setting

Factory set to Normal

- 9 -

Image 11
Contents Operations Manual Table of Contents General Information Features+ label backing CS2000 DiagramCS2000 Quick Start CS2000-QD Quick Start Mounting Installation Voltage CS2000 WiringOptoisolator CS2000-QD WiringOperation Label PlacementOperation Features Contrast Setting Operation FeaturesOperation Features Output Mode Operation Features Light/Dark OperationOverview Adjusting Label SensitivityEasy Setup Possible ProblemsDisabling Missing Label Compensation Missing Label CompensationEnabling Missing Label Compensation Changing a Feature Program ModeEntering Program Mode Table of FeaturesGeneral SpecificationsNeS aer DimensionsCleaning Instructions Cleaning InstructionsRepairs Warranty Terms & ConditionsWarranty After Repair Warranty