Contec CS2000-QDCS2000 manual Entering Program Mode, Table of Features, Changing a Feature

Page 14

Program Mode

Entering Program Mode:

Program Mode is used to change any or all of the Operation Features. To enter Program Mode depress the push-button until the yellow and green LED's begin toggling (30 sec.), then release. The LED's will then output the current set-up configuration (and every 3 sec. thereafter). For example: an output of yellow, yellow, yellow tells you that the current configuration is Level Shift, Light Operate, and Normal Contrast Setting.

Table of Features:

1

 

 

 

 

 

OUTPUT MODE

 

 

 

 

 

 

 

 

*A. Level Shift - (default factory setting)

 

 

 

 

 

Yellow LED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B Pulse

 

 

 

 

 

 

 

 

 

 

 

Green LED

 

 

 

 

LIGHT/DARK OPERATION

 

 

 

 

 

 

 

 

 

*A. Output on Web - Light - (default factory setting)

 

 

 

 

 

Yellow LED

 

 

Level Shift Output

 

 

 

Pulse Output

 

 

WEB

 

LABEL

 

 

 

 

LABEL

WEB

LABEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

ON

 

 

 

2

 

 

 

OFF

 

 

 

 

OFF

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

m.s.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B. Output on Label - Dark

 

 

 

 

 

Green LED

 

 

Level Shift Output

 

 

 

Pulse Output

 

 

WEB

 

LABEL

 

 

 

 

LABEL

WEB

LABEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

ON

2 m.s.

ON

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

3

 

 

 

CONTRAST SETTING

 

 

 

 

 

 

 

 

*A. Normal Contrast Setting - (default factory setting)

 

 

 

 

 

Yellow LED

 

B. Low Contrast Setting

 

 

 

 

 

 

 

 

 

 

 

Green LED

Changing a Feature:

To change a feature, depress the push-button the corresponding number of times. This will change the current feature from A to B, or from B to A. For example: If you wanted to change the output from Level Shift to Pulse, you would depress the push-button 1 time - the LED's would then output green, yellow, yellow. Repeat this step if you want to change more than one feature.

Exiting Program Mode:

To exit Program Mode depress the push-button until the yellow and green LED's begin toggling (2 sec.), then release. This puts you back in the standard operating mode.

- 12 -

Image 14
Contents Operations Manual Table of Contents Features General InformationCS2000 Diagram + label backingCS2000 Quick Start CS2000-QD Quick Start Installation MountingCS2000 Wiring VoltageCS2000-QD Wiring OptoisolatorLabel Placement OperationOperation Features Light/Dark Operation Operation FeaturesOperation Features Output Mode Operation Features Contrast SettingPossible Problems Adjusting Label SensitivityEasy Setup OverviewDisabling Missing Label Compensation Missing Label CompensationEnabling Missing Label Compensation Table of Features Program ModeEntering Program Mode Changing a FeatureSpecifications GeneralDimensions NeS aerCleaning Instructions Cleaning InstructionsAfter Repair Warranty Warranty Terms & ConditionsWarranty Repairs

CS2000, CS2000-QD, CS2000-QDCS2000 specifications

The Contec CS2000 series, comprising models CS2000-QDCS2000, CS2000-QD, and CS2000, emerges as a cutting-edge solution in the realm of data acquisition and control systems. Renowned for their versatility and reliability, these models cater to a wide range of industries, including manufacturing, healthcare, and research facilities.

One of the standout features of the Contec CS2000 series is its seamless integration capability. Each model offers robust connectivity options, including USB, Ethernet, and RS-232, facilitating easy communication with various devices and systems. This makes it suitable for both standalone applications and more complex integrated setups.

The series is equipped with high-precision analog input channels, supporting a wide input range. This feature allows for accurate data collection and monitoring, which is crucial for applications demanding high fidelity in readings. Additionally, the digital output channels provide versatile control options that can trigger devices or send commands based on the collected data.

Technologically, the CS2000 series is designed with advanced signal processing capabilities. This ensures that noise reduction and filtering algorithms are employed, resulting in cleaner data signals and better overall performance. The user-friendly interface makes it easy for operators to configure settings and manage data efficiently, enhancing productivity across various applications.

Another noteworthy characteristic of the Contec CS2000 series is its robust protective design. Built to withstand challenging environments, these devices often include features such as IP-rated enclosures and extended temperature ranges, ensuring reliability in both indoor and outdoor settings.

The CS2000-QDCS2000 model, in particular, stands out due to its high-speed data acquisition features, making it ideal for real-time monitoring applications. The CS2000-QD variant brings additional customization options for specialized tasks, whereas the CS2000 provides essential functionalities needed for standard operations.

With outstanding performance, high adaptability, and user-friendly features, the Contec CS2000 series positions itself as an essential tool for professionals seeking reliable data acquisition and control solutions. Whether you are in research, industrial automation, or environmental monitoring, the Contec CS2000 lineup delivers the precision and efficiency needed to succeed in today’s data-driven environment.