Omega Engineering FP-5060 manual Surface Mount Instructions, Fitting Installation, Calibration

Page 4

3. Surface Mount Instructions

1

Mounting surface

2Remove sensor then use correct screws for panel material.

#6 or M3 metric screws recommended

120°

Mounting surface (top),

Mounting surface (side)

68 mm (2.68 in.) bolt circle

 

4. Fitting Installation

CAUTION:

• Maximum pipe fi tting torque: 10 ft - lbs (13 N m).

• DO NOT overtighten. Failure to observe torque specifi cation may permanently damage sensor ports.

Pipe

Pipe fitting

FP-5060

Pipe fitting

Pipe

 

Sealant

Technical Notes:

Compatible fi ttings (customer supplied): Female union (shown), reducer, or hose barb type.

Always apply thread sealant to sensor port threads to prevent leakage.

5. Calibration

The K-Factors listed below represent the number of pulses the sensor will generate for each engineering unit of fl uid which passes. They are listed in U.S. gallons, liters and mL by sensor model:

Sensor

PULSES PER

PULSES PER

PULSES PER

Model

U.S. GAL

LITER

mL

FP-5061

9950

2629

2.629

FP-5062

9950

2629

2.629

FP-5063

3160

834.9

0.835

FP-5064

3160

834.9

0.835

page 4

OMEGA FP-5060 Series Micro Flow Sensor

Image 4
Contents User’sGuide Servicing North America Instrument Wiring Safety InstructionsSeries Sensor Recommended Sensor PositionFitting Installation Surface Mount InstructionsPipe Pipe fitting FP-5060 Sealant CalibrationSpecifications Omega FP-5060 Series Micro Flow Sensor WARRANTY/DISCLAIMER OMEGA…Of Course