JDS Uniphase RM3750 user manual Safety Information, Instructions, and Symbols

Page 4

RM3 SERIES BACKREFLECTION METER

USER’S MANUAL

Website: http://www.jdsuniphase.com

Safety Information, Instructions, and Symbols

Safety Information

Classification

The RM Series Backreflection Meter consists of an exposed metal chassis that is connected directly to earth via a power cord and, therefore, is classified as a Class 1 instrument.

Disconnecting from Line Power

Some of the circuits are powered whenever the unit is connected to the AC power source (line power). To ensure that the unit is not connected to the line power, disconnect the power cord from either the power inlet on the unit’s rear panel or from the AC line-power source (receptacle). The power cord must always be accessible from one of these points. If the unit is installed in a cabinet, the operator must be able to disconnect the unit from the line power by the system’s line-power switch.

Line Power Requirements

The RM meter operates from any single-phase AC power source that supplies between 100 and 240 V at a frequency range of 50 to 60 Hz. The maximum power consumption of the RM meter is 25 VA. The unit can also be operated using its internal 6V DC rechargeable battery.

Fuse Type

The fuse type used by the unit is (5 x 20) mm, 1 A/250 V (fast).

Laser Specifications

Laser specifications are provided in Table 1.

Table 1: Specifications

Parameter

Single-mode (SM)

Multimode (MM)

 

 

 

 

Wavelength

980*, 1310, 1480, 1550, 1625,

850, or 1310 ± 20 nm

 

or 1650 ± 10 nm

 

 

 

 

 

 

 

 

Class

1

 

1

 

 

 

 

 

 

Fiber Type

9/125 µm SM(*5/125 µm SM)

50/125 µm MM

 

62.5/125 µm

 

 

 

 

MM

 

 

 

 

 

Maximum Accessible

-15 dBm

-23 dBm

 

-25 dBm

Emission Level

 

 

 

 

 

 

 

 

 

Maximum Output Power

-4 dBm

-4 dBm

 

-4 dBm

 

 

 

 

 

Numerical Aperture

0.13 (*0.14)

0.20

 

0.28

 

 

 

 

 

Effective Numerical

0.20 (*0.21)

0.27

 

0.34

Aperture

 

 

 

 

 

 

 

 

 

10112341 Rev 002

Page 4 of 39

Image 4
Contents RM3 Series Backreflection Meter User’s ManualContents Customized Features and Test Data Programming GuideSafety Information, Instructions, and Symbols Safety InformationClass Laser Product Before Initializing and Operating the Unit Safety InstructionsOperating the Unit RM3 Series Backreflection Meter USER’S Manual Symbol Safety SymbolsProceeding CE Compliance ComplianceFDA-CDRH Compliance CSA / IEC Compliance RM3 Series Backreflection Meter USER’S Manual General Information and Specifications General InformationLoss and Power Measurements Backreflection MeasurementsKey Features Output PortInternal Light Sources Hybrid JumpersOptional Accessories Standard AccessoriesApplications Specifications Parameter Specification Single-mode MultimodeFlexcor is a trademark of CorningR Physical ElectricalEnvironmental Before Initializing and Operating the Unit Getting StartedInitial Inspection Operating Environment Storing and ShippingCleaning Connectors Powering Up the Meter Connector Cleaning connector type can varyFront Panel Operating and Maintenance InstructionsKey/LED Description Rear Panel Termination TechniquesComponent Function Termination Techniques for Single-mode Fiber except 980 nmMeasuring Backreflection for Single-mode except 980 nm Setting Up the Meter for Backreflection Measurements Backreflection MeasurementsMeasuring Backreflection Setting Up the Meter for Loss and Power Measurements Loss and Power MeasurementsBackreflection Accuracy and Range Measuring Power Loss and Power MeasurementsMeasuring Relative Power Insertion Loss Measuring Absolute PowerData Logging Using the Foot Pedal Messages and SymbolsPower Accuracy Display DescriptionCalibrating the Meter StabilizingBackreflection Calibration Adjustment Power Calibration AdjustmentCleaning the Connector Ends Cleaning the UnitMaintaining the Meter Replacement of Internal Fuses Recharging the BatteryTroubleshooting Front Panel Connectors Long Cables for single mode model only, except 980 nm modelLoss Before the DUT Reflections Before the DUTOther Display Problem Solution Laser StabilityCalibration Up the Meter for BackreflectionRS232 Interface Specifications Name Symbol Pin Number Signal DirectionProgramming Guide RS232 Serial InterfaceCommand Action Left Dip Switch Switch Setting MeaningRight Dip Switch RS232-GPIB ConverterProgramming Examples RS232 Interface Program ExampleCustomized Features and Test Data

RM3750 specifications

The JDS Uniphase RM3750 is a cutting-edge optical spectrum analyzer that has garnered attention in various telecommunications and photonics applications. Renowned for its versatility and accuracy, the RM3750 combines advanced technologies to provide users with unprecedented measurement capabilities, making it an essential tool for researchers and engineers working in fiber optics, laser development, and spectral analysis.

One of the standout features of the RM3750 is its wide dynamic range. This feature allows users to obtain precise measurements across a broad spectrum of optical signals, which is crucial in environments where signal strength can vary significantly. The analyzer is designed to handle both high-intensity signals and weak optical events, ensuring that no detail is missed during analysis.

The RM3750 incorporates a high-resolution detection mechanism that enables it to distinguish closely spaced wavelengths. This characteristic is particularly beneficial in applications where wavelength spacing is minimal, such as in dense wavelength division multiplexing (DWDM) systems. The high resolution also allows for accurate characterization of spectral features, including signal peaks and noise.

In addition to its impressive measurement capabilities, the RM3750 supports advanced analysis and real-time monitoring. Users can visualize spectral data through an intuitive graphical interface, which aids in the quick interpretation of results. The instrument is equipped with real-time data processing capabilities, allowing users to observe changes in optical signals as they occur, a critical feature for dynamic environments like live signal monitoring.

The JDS Uniphase RM3750 is not only about hardware; it also comes with an array of software tools designed to enhance functionality and ease of use. These tools allow for automated measurements, data logging, and integration with other laboratory instruments. Moreover, the ability to export data in various formats facilitates easy sharing and analysis across platforms.

Another notable characteristic of the RM3750 is its compact design and robust build quality. This ensures that it can operate effectively in demanding laboratory conditions while being portable enough for field applications.

In conclusion, the JDS Uniphase RM3750 optical spectrum analyzer stands out for its combinations of wide dynamic range, high resolution, real-time monitoring, and user-friendly software integration. These characteristics make it an exceptional tool for professionals in telecommunications and optical research, enabling them to conduct more accurate and insightful measurements.