Leica 764555, 764558 manual Technical data, Measuring conditions, Measuring range

Page 20

Error

Cause

Remedy

Error

Hardware error

Switch on/off the device several

 

 

times. If the symbol still appears,

 

 

then your instrument is defec-

 

 

tive. Please call your dealer for

 

 

assistance.

Technical data

Distance measurements:

 

Measuring accuracy up to 10 m (2 σ)

typically: ± 1.0 mm*

Power Range Technology™:

0.05 m to 200 m

Range (use target plate from about 100 m)

 

Smallest unit displayed

0.1 mm

Distance measurement

9

Minimum/maximum measurement, Conti-

9

nuous measurement

 

Area/volume calculation of room data

9

Addition / subtraction

9

Indirect measurement using Pythagoras

9

Trapezium measurement

9

Tilt measurements:

 

Tilt sensor:

 

Accuracy (2 σ)

 

- to laser beam

- 0.1° / +0.2° **

- to the housing

± 0.1° **

Indirect measurement using tilt sensor

9

(direct horizontal distance)

 

Angle measurement using tilt sensor

9

(360°)

 

General:

 

Laser class

II

Laser type

635 nm, < 1 mW

Ø laser point

6 / 30 / 60 mm

(at distances)

(10 / 50 / 100 m)

Autom. laser switch-off

after 3 min

Autom. instrument switch-off

after 6 min

 

Display illumination

9

GB

Multifunctional endpiece

9

 

Timer (self-triggering)

9

 

Save constant value

9

 

Historical storage

30 values

 

BLUETOOTH® 2.0

QD ID B014433

 

Range of BLUETOOTH® Cl. 2

10 m

 

Tripod thread (Type: 1/4-20)

9

 

Battery life,

up to

 

Type AA, 2 x 1.5V

5 000 measurements

 

Protection against splashes and dust

IP 54, dust-proof,

 

 

splash-proof

 

Dimensions

143.5 x 55 x 30 mm

 

Weight (with batteries)

195 g

 

Temperature range:

 

 

Storage

-25°C up to +70°C

 

 

(-13°F up to +158°F)

 

Operation

-10°C up to +50°C

 

 

(14°F up to +122°F)

 

*maximum deviation occurs under unfavourable conditions such as bright sunlight or when measuring to poorly reflecting or very rough surfaces. Measuring accuracy between 10 m and 30 m may deteriorate to approx. ± 0.025 mm/m, for distances above 30 m to ± 0.1 mm/m. In long range mode the maximum deviation from a distance of 30 m increases to +/- 0.15 mm/m.

**applies at room temperature. For the whole operating temperature range the maximum deviation increases by +/- 0.1°.

Measuring conditions

Measuring range

The range is limited to 200 m.

At night or dusk and if the target is in shadow the measuring range without target plate is increased. Use a target plate to increase the measurement range during daylight or if the target has poor reflection properties.

Leica DISTO™ D8 LCA782205a gb

17

Appendix

Image 20
Contents Leica Disto D8 Page Leica Disto D8 Safety Instructions ContentsPrecautions Limits of useAreas of responsibility Hazards in useUse of the product with Bluetooth Electromagnetic Compatibility EMCLaser classification Integrated distancemeterStart-up LabellingInserting/replacing batteries Changing the reference point multifunctional endpieceSee figure E Display in normal modeKeypad Display in digital pointfinder mode SettingsMenu functions Menu functionsSetting the unit for distance measurements Setting the unit for tilt measurementsLong range Mode Display illuminationReset returning the instrument to the factory settings OffsetDigital pointfinder image black / white Level in status fieldOperation MeasuringFunctions Addition / subtractionArea FunctionsSurface area of the walls Circumfe Rence Volume Trapezium measurementResult is shown in the summary row Height Press and hold Ruction of wooden frames Stake out functionIndirect measurement Indirect measurement with tilt sensor Profile measurement Double tilt measurement with one measured distanceDouble tilt measurement with two measured distances Measurement, for example the inclination angleWorking with Bluetooth Appendix Transmitting the measurementMessage codes Selecting particular values in the displayMeasuring range Technical dataMeasuring conditions Target surfaces WarrantyCare Leica Disto D8 Exit Switzerland Translation of original text LCA782205a