Emerson CF701BS00 Remove the three switch housing mounting, Screws from the switch housing plate

Page 5

9.Remove the center plug screw from the switch housing assembly (Figure 4). Remove and retain the two wire connectors.

SWITCH CUP CONNECTOR

SCREWS

SWITCH

CUP

CENTER PLUG

SCREW

Figure 4

10.Remove and retain the lockwasher and nut from the light fitter. Insert the black and white wires from the light fitter through the center hole in the switch housing assembly. Thread the switch housing assembly onto the light fitter. Reinstall the lockwasher and nut and tighten securely (Figure 5).

11.Connect the white wire from the ceiling fan to the white wire of the light fitter. Connect the blue wire from the ceiling fan to the black wire of the light fitter. Use wire connectors (previously removed) to make connections (Figure 5).

12.Engage the connector of the switch housing assembly with the motor connector (Figure 6). The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the connectors latch closes properly.

13.Carefully tuck all wires and splices into the switch housing.

SWITCH

HOUSING

ASSEMBLY

SWITCH HOUSING

CONNECTOR

MOTOR CONNECTOR

SWITCH HOUSING

MOUNTING SCREW

Figure 6

14. Remove the three switch housing mounting

screws (Figure 7) from the switch housing plate.

Position the switch housing assembly on the

BLUE WIRE BLACK WIRE

SCREWS

NUT

SPRING

LOCKWASHER

SWITCH

HOUSING

ASSEMBLY

BOWL

CAP

Figure 5

SWITCH CUP

CONNECTOR

WIRE

CONNECTORS

WHITE WIRES

FAN

SWITCH

CHAIN

LIGHT

FITTER

switch housing plate and align the holes in the

switch housing assembly with the holes in the

plate. Secure the switch housing assembly by

installing the three mounting screws (Figure 7).

!WARNING

Do not pinch wires between the switch housing assembly and the switch housing plate.

LIGHT FITTER

SWITCH HOUSING

ASSEMBLY

MOUNTING

SCREWS (3)

Figure 7

5

U.L. Model No.: CF701

Image 5
Contents Read and Save These Instructions Safety Instructions Up to 50 ft 50-100 ft MaterialsBlade assemblies How to Put Your Ceiling Fan TogetherScrews from the switch housing plate Remove the three switch housing mountingPosition the switch housing assembly on Switch housing plate and align the holesElectrical Requirements Installing Hanger BracketWiring The Ceiling Fan Using Your Ceiling Fan Trouble Shooting MaintenanceAccessoriesDescription Repair Parts ListingHOW to Order Repair Parts Repair PartsAir Comfort Products