BP7308 LORRAINE KF240 2/15/06 3:21 PM Page 13

40-WATT (MAX.)

CANDELABRA BULBS (3)

THREADED

NIPPLE

REVERSING

SWITCH

LIGHT

FITTER

ANTENNA WIRE

ON

RECEIVER

CODE

WALL CONTROL

SWITCH

LEVERS

 

 

4

3

2

1

 

 

RECEIVER

 

 

 

 

ON

 

 

 

 

 

SWITCH LEVERS

 

 

 

 

 

1

2

3

4

CODE

ON

 

 

 

SWITCH

 

 

 

 

WALL

 

 

 

 

CONTROL

 

 

 

LOWER

RUBBER

GLASS

WASHER

METAL

WASHER

Figure 17

1/8 x 24 NUT

DECORATIVE CAP

FINIAL NUT

Figure 18

Installation of Wall

Control

SINGLE-POLE INSTALLATION

Setting Operating

Frequency of Wall

Control and Receiver

(Figure 18)

Your wall control and receiver have code switches which must be set in one of 16 possible code combinations. The four levers (numbered 1, 2, 3, and 4) on the switches are factory-set in the ON (up) position. Change the switch settings as follows:

1. Slide the four switch levers in the wall control to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down.

2. In the receiver, slide the four switch levers to the same positions as set in the wall control. Make sure the levers on both switches are in the same positions, otherwise the fan will not operate.

(Figure 19)

HOT

BLK

FAN/LIGHT

 

WALL CONTROL

 

 

EMERSON

BLACK

 

 

 

BLACK

LOAD

NEUTRAL

 

 

GROUND

 

 

 

REMOTE CONTROL

 

 

RECEIVER LOCATED

 

 

WITHIN THE CEILING

 

 

COVER

 

 

 

Figure 19

1. Disconnect power at circuit breaker or remove fuse.

2. Remove faceplate and screws from existing wall control. Pull control out from the wall box. Determine the “hot” wire and the “load” wire and disconnect these wires from control. Do not attempt to disconnect any wires not already connected to existing control.

3. Before installing wall control, place wall control in “OFF” mode by pushing “ON/OFF” switch to the “OFF” position.

13

Image 13
Contents Lorraine Additional Safety Instructions for Installation Safety InstructionsDate Code Unpacking Instructions MaterialsEmerson How to Assemble Your Ceiling Fan Electrical Requirements Ceiling Fan ProceduresGeneral FAN Blade Previously removed Figure Using the hex wrench supplied How to Hang Your Ceiling Fan Outlet BOX TWO Screws Supplied With Stud How to Wire Your Ceiling FanYour ceiling fan is now installed Setting Operating Frequency of Wall Control and Receiver Installation of Wall ControlDo not connect any neutral white Required WAY WIRlNG Diagram NEW ConstructionOperating Your Ceiling Fan Switch on the Fan/Light Wall Control is in the on positionImportant Care Instructions MaintenanceAccessoriesFor your Ceiling Fan Trouble Probable Cause Suggested Remedy Trouble ShootingHOW to Order Repair Parts Repair PartsKey Part Numbers Model No Description Repair Parts ListingWhat The Warranty Covers Limited Warranty