Dukane AN400 manual Plc, Status Output Interface Examples

Page 5

DUKANE

- 5 -

Application Note

 

Intelligent Assembly Solutions

AN400

The DPC status output pins can be configured to adapt to several types of automated devices. The ratings for the DPC Status output pins are:

Maximum Voltage Rating = +24 VDC

Maximum Current Rating = 100 mA

Status Output Interface Examples:

DPC IV

Bad Part

Suspect

Part

Good Part

Ready

Output

Common

3

4

5

6

7

J602

200-1203

Cable

+ 24 VDC

Input

Device

Input

Device

Input

Device

Input

Device

PLC

DPC IV status output configuration for use with a PLC requiring sinking inputs.

Dukane Corporation

2900 Dukane Drive Saint Charles, IL 60174 USA

Phone (630) 797-4900 FAX (630) 797-494955105

http://www.dukane.com/us5

© Dukane Corporation 2004. All rights reserved.

Image 5
Contents Application Note Topics Dukane Pin Number DPC Signal Name DPC Signal Type Status Output signals for the J602 Connector Intelligent Assembly Solutions AN400Status Output Signal Descriptions Status Output Interface Examples PLCDPC 200-1203 System Input signals for the J602 Connector System Input Interface Examples Dukane