DUKANE | - 3 - | Application Note |
| ||
Intelligent Assembly Solutions | AN400 |
|
|
|
|
| Pin # | Conductor Color |
|
| 1 | Red |
|
| 2 | Black |
|
| 3 | Blue / Black |
|
| 4 | Green / White |
|
| 5 | Blue / White |
|
| 6 | Red / Black |
|
| 7 | White / Black |
|
| 8 | White |
|
| 9 | Orange |
|
| 10 | Blue |
|
| 11 | Orange / Black |
|
| 12 | Red / White |
|
| 13 | Green Black |
|
| 14 | Black / White |
|
| 15 | Green |
|
|
|
|
|
| Part Number | Length |
|
| 10 FT |
| |
| 15 FT |
| |
| 20 FT |
| |
| 25 FT |
| |
| 30 FT |
| |
|
|
|
|
Status Output signals for the J602 Connector:
There are four status output signals available on the J602 connector. Each of these outputs are driven by a solid state relay that creates a switch closure between the specified output pin and the Output Common pin. These pins can be configured within the DPC software menus to provide a signal that accommodates the requirements of most automation interface equipment. The available configurations for these output signals are:
Active High Outputs – This setting will produce a closed switch condition between the specified output pin and the Output Common pin when the output signal is activated. (Factory default setting)
Active Low Outputs - This setting will produce an open switch condition between the specified output pin and the Output Common pin when the output signal is activated.
Maintained Outputs - This setting will produce an output signal that is maintained from the completion of a welding cycle until the beginning of the next welding cycle activation. (Factory default setting)
Pulsed Outputs - This setting will produce an output signal that is pulsed a single time for 100 mS as the end of the welding cycle.
Note: Please refer to the Hardware menu section of the DPC IV manual for further information on these features.
Dukane Corporation
2900 Dukane Drive Saint Charles, IL 60174 USA
Phone (630)
http://www.dukane.com/us3
© Dukane Corporation 2004. All rights reserved.