Campbell Hausfeld GW4500 specifications Pre-Operation

Page 6

Operating Instructions and Parts Manual

Pre-Operation

GROUNDING

3. Rotate the engine switch to the ON

LOCATION

1.

Use the ground terminal and wing

 

position.

 

nut on the welder / generator frame

4.

Adjust the choke lever as follows:

Selecting the proper location can

 

 

to connect the unit to a suitable

significantly increase performance,

 

 

a. For cold engine, move the choke

 

ground source. Securely fasten the

 

reliability and life of the arc welder.

 

 

lever as far as possible to the left,

 

end terminal of the ground wire to

 

• For best results locate the welder /

 

 

choke fully ON, position.

 

the ground terminal on the

 

generator in an environment that is

 

welder / generators frame. Tighten

 

b. For warm / hot engine, move the

clean and dry. Dust and dirt in the

 

the washer and wing nut on top of

 

choke lever midway between the

unit retain moisture and increase

 

the ground wire end terminal.

 

choke and run positions.

wear of moving parts.

2. The ground wire should be made

5. Pull the starter rope with a brisk,

• Store electrodes in a clean, dry

 

of #8 gauge wire. Do not use wire

 

smooth motion.

location with low humidity to

 

with a higher gauge number.

 

NOTE: Some models may be

preserve the flux coating.

 

Higher gauge numbers indicate

 

equipped with an electric starter.

INSTRUCTIONS

 

thinner wire, which may not

 

For models equipped with an

1. Check engine oil level. Oil is NOT

 

provide an adequate ground path.

 

electric starter, turn the key.

mixed with the gasoline, however

3. The other end of the ground wire

6. After each start up, allow the

adequate oil supply is necessary for

 

must be securely fastened to an

 

engine to run for 2-3 minutes with

proper engine lubrication. Refer to

 

approved ground source.

 

no load.

the Engine Manual for SAE, API and

The following are ground sources

7.

As the engine warms up and

fill quantity specifications. Unit is

approved by the National Electric

 

stabilizes, adjust the choke lever

shipped without oil in engine.

 

Code. Other ground sources may be

 

to the right, until the lever is

2. Use of a Ground Fault Interrupter

 

acceptable. Refer to the National

 

positioned as far as possible to the

(GFI) is strongly recommended.

Electric Code and local regulations for

 

right.

Ground Fault Interrupters can

further ground source information. If

 

 

 

Engine speed is

 

 

 

significantly reduce the possibility

not sure of regulations or procedures,

 

 

 

preset to provide

 

 

 

 

 

 

of injury if an electrical short occurs.

obtain assistance from a qualified

proper output voltage. Never attempt

In order to install a GFI, the

(licensed or certified) electrical

to modify or adjust engine speed or

output voltage.

welder / generators neutral wire

technician.

ENGINE BREAK-IN

must be internally grounded to the

 

a. An underground water pipe at

welder / generators frame, and the

 

After initial start-up, the engine

 

least ten feet in length

frame must be properly grounded

 

should be broken in according to the

 

b. A non-corrosive underground

to the earth.

 

manufacturer's instructions. Refer to the

 

pipe at least eight feet in length

 

 

A Ground Fault

 

engine manual for the proper break-in

 

 

 

and 3/4 inch diameter

 

 

 

procedure.

 

 

Interrupter may

 

 

 

 

c. A steel or iron underground rod

 

 

 

not be effective if used on a welder /

 

 

 

 

 

 

at least eight feet in length and

SHUT-OFF

generators that is not grounded! Refer

 

to the section entitled Grounding for

 

5/8 inch diameter

1. Shut off and remove all electrical

proper steps to ground the welder /

 

d. A non-ferrous rod at least

 

load devices from the welder /

generator.

 

eight feet in length, 1/2 inch

 

generator.

3. When installing a GFI, be sure

 

in diameter, and approved for

2.

Allow the engine to run for 2-3

to follow all national and

 

grounding purposes

 

 

minutes with no electrical loads.

local regulations. If not sure of

 

 

 

Any rod or pipe used for grounding

3.

Rotate the engine switch to the OFF

regulations or procedures, obtain

must be driven to eight feet deep or

 

position.

assistance from a qualified (licensed

 

buried in the deepest possible trench.

4.

Verify that the welder / generator

or certified) electrical technician.

 

 

 

 

 

STARTING

 

has completely stopped.

 

 

 

1.

Remove all electrical loads from the

5.

Close the fuel supply valve.

 

 

 

 

welder / generators.

 

 

 

 

6.

Allow the unit to cool before

 

 

 

2.

Move fuel shut-off lever as far as

 

 

 

 

installing any covers.

 

 

 

 

 

 

possible to the right to enable fuel flow.

www.chpower.com

6

Image 6
Contents Specifications Table of ContentsSafety Guidelines DescriptionCalifornia Proposition General Safety InformationGeneral Safety Emissions GW4500 Additional Safety Standards Gas Metal Arc Welding Gmaw Getting To Know Your Welder / GeneratorFlux Cored Arc Welding Fcaw Gas Tungsten Arc Welding GtawPre-Operation LOW OIL Shutdown Estimated Power Usage WattsGenerator Operation Load DevicesWelder Operation Maintenance WeldingWelding Guidelines ARC Length Travel SpeedWeld Pass Testing Welder / GeneratorSlag Removal DiodesTroubleshooting Chart General Troubleshooting Chart GeneratorTroubleshooting Chart Welder Troubleshooting Chart WeldsWiring Diagram AC Welder / Generator Welder / Generator Assembly For replacement parts or technical assistance, call Replacement Parts ListAlternator Assembly For replacement parts or technical assistance, call Limited Warranty