Your wall control and receiver have code switches which must be set in one of 16 possible code combinations. The four levers (numbered 1, 2, 3, and 4) on the switches are
1. Slide the four switch levers in the wall control to your choice of ON (up) or down positions. Use a
Installation of Wall
Control
SINGLE-POLE INSTALLATION
(Figure 19)
HOT | BLK | FAN/LIGHT |
|
WALL CONTROL |
| ||
| EMERSON | BLACK |
|
|
| BLACK | LOAD |
NEUTRAL |
|
| GROUND |
|
|
| |
REMOTE CONTROL |
|
| |
RECEIVER LOCATED |
|
| |
WITHIN THE CEILING |
|
| |
COVER |
|
|
|
Figure 19
2.In the receiver, slide the four switch levers to the same positions as set in the wall control. Make sure the levers on both switches are in the same positions, otherwise the fan will not operate.
ANTENNA WIRE
ON
1. Disconnect power at circuit breaker or remove fuse.
2. Remove faceplate and screws from existing wall control. Pull control out from the wall box. Determine the “hot” wire and the “load” wire and disconnect these wires from control. Do not attempt to disconnect any wires not already connected to existing control.
3. Before installing wall control, place wall control in “OFF” mode by pushing “ON/OFF” switch to the “OFF” position.
RECEIVER | CODE | WALL CONTROL | ||||
SWITCH | LEVERS |
|
| |||
4 | 3 | 2 | 1 | |||
|
|
!WARNING
ON
RECEIVER
SWITCH LEVERS
1 2 3 4 | CODE |
ON | SWITCH |
|
WALL
CONTROL
Figure 18
Do not connect any neutral (white) wire to this control. Incorrect wiring will damage this control.
4. Connect one black wire of wall control to the “hot” wire. Securely connect wires with wire connectors supplied (Figure 20).
5. Connect one black wire of wall switch to the “load” (black) wire in wall box. Securely connect wires with wire connector supplied.
6. Screw wall control into wall box and install decorator style faceplate (included). Leave wall control in “OFF” mode until fan installation is completed.