7. Refer to page 5 and complete the ceiling fan installation.
5. Connect one black wire of the wall control to both remaining traveler wires in the wall box and secure with wire connector supplied.
HI |
|
|
| LIGHT |
|
MED |
|
|
LOW |
|
|
FAN OFF |
|
|
EMERSON | ® | |
| ||
OFF | ON |
|
Figure 20
BLK | T |
|
| HOT |
|
|
| |
|
|
|
|
|
|
|
| |
| O |
|
|
|
|
|
|
|
| 1 | 2 | 0V |
|
| O |
| E |
|
|
|
|
| ||||
|
|
| AC | S | C | |||
|
|
|
|
| UR |
|
T |
|
| |
BLACK | O LOAD |
|
|
|
| D | |
|
|
| N |
|
|
| U |
| G | R | O |
|
| ||
FAN/LIGHT |
|
| |
|
| WALL | |
WALL |
|
| |
CONTROL |
|
| BOX |
NOTE: Retrofit
3-WAY WIRlNG DIAGRAM: NEW CONSTRUCTION
3-WAY INSTALLATION
HOT |
| FAN/LIGHT |
|
|
| WALL |
|
| EMERSON | CONTROL | EMERSON |
(On fan controlled by two different wall controls) (See Figures 21 and 22.)
1. Disconnect power at circuit breaker or remove fuse.
2. At all wall box locations remove faceplates and screws from existing controls. Pull controls out from wall boxes and determine which wall box contains the “hot” lead and which wall box contains the “load” wire. Also, identify traveler wires which are common to both wall boxes. Disconnect wires from existing controls only. Do not attempt to disconnect any wires not already connected to existing controls.
3. Before installing wall control, place wall control in “OFF” mode by pushing “ON/OFF” switch to the “OFF” position.
!WARNING
Do not connect any neutral (white) wire to this control. Incorrect wiring will damage this control.
4. Install a wall control in the wall box containing the “hot” wire first. Connect the black wire of the wall control to the “hot” wire. Securely connect wires with wire connectors supplied.
BLACK | BLK | BLK |
|
|
| LOAD |
| ||
| TRAVELER |
|
| |
|
| BLACK |
| |
NEUTRAL | WIRE |
| GROUND | |
|
|
REMOTE CONTROL
RECEIVER LOCATED
WITHIN THE CEILING
COVER
Figure 21
6. Place wall control into wall box. Screw in place and install decorator style faceplate (included).
7. Next, install the other wall control into the wall box containing the load wire. Connect the black wire of the wall control to the traveler wire(s) already connected to the black wire (in the other wall box). Secure with wire connectors supplied.
8. Connect one black wire of the wall control to the “load” (black) wire and secure with wire connector supplied.
9. Place the second wall control into the wall box. Screw in place and install decorator style faceplate (included). Leave switch in “OFF” mode until fan installation is completed.
10. Refer to page 5 and complete the ceiling fan installation .