SECTION 8 – TROUBLESHOOTING
8-1. Troubleshooting
A. Welding
Trouble | Remedy |
|
|
No weld output; no generator power | Be sure all equipment is disconnected from receptacles when starting unit. |
output at ac receptacles. |
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, rotor, stator, integrated rectifier |
| SR1, and integrated rectifier SR2. |
|
|
No weld output; generator power out- | Check Amperage control setting. |
put okay at ac receptacles. |
|
|
|
| Check weld connections. |
|
|
| Have Factory Authorized Service Agent check Amperage control R1, stator, and integrated rectifier |
| SR1. |
|
|
Low weld output. | Check Amperage control setting. |
|
|
| Service engine air cleaner. |
|
|
| Check weld cable size and length. |
|
|
| Have Factory Authorized Service Agent check engine speed, and adjust if necessary. |
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, rotor, stator, integrated rectifier |
| SR1, and integrated rectifier SR2. |
|
|
High weld output. | Check Amperage control setting. |
|
|
Erratic weld output. | Check Amperage control setting. |
|
|
| Tighten and clean connections to electrode and workpiece. |
|
|
| Use dry, |
|
|
| Remove excessive coils from weld cables. |
|
|
| Clean and tighten connections both inside and outside welding generator. |
|
|
| Check governor linkage for smooth, |
|
|
| Have Factory Authorized Service Agent check engine speed, and adjust if necessary. |
|
|
B. Generator Power
Trouble | Remedy |
|
|
No output at generator power ac re- | Be sure all equipment is disconnected from receptacles when starting unit. |
ceptacles; no weld output. |
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, rotor, stator, integrated rectifier |
| SR1, and integrated rectifier SR2. |
|
|
No output at generator power ac re- | Reset circuit breaker (see Section |
ceptacles; weld output okay. |
|
|
|
| Check Current control setting. Set Current control at max for generator power. |
|
|
| Check receptacle wiring and connections. |
|
|
| Have Factory Authorized Service Agent check engine speed, and adjust if necessary. |
|
|
| Have Factory Authorized Service Agent check stator windings. |
|
|
High output at generator power ac | Have Factory Authorized Service Agent check engine speed, and adjust if necessary. |
receptacles. |
|
|
|
Low output at generator power ac | Check Current control setting. Set Current control at max for generator power. |
receptacles. |
|
|
|
| Have Factory Authorized Service Agent check engine speed, and adjust if necessary. |
|
|