Dimplex LIK 8MER Purpose of the Heat Pump, Scope of Delivery, Application, Operating Principle

Page 4

2

English

2Purpose of the Heat Pump

2.1Application

The air-to-water heat pump is designed for use in existing or newly built heating systems.

It is designed exclusively for heating and cooling heating water!

In heating operation, the heat pump is suitable for mono energy and bivalent operation down to an external temperature of - 20 °C.

Proper defrosting of the evaporator is guaranteed by maintaining a heating water return flow temperature of more than 18 °C dur- ing continuous operation.

The heat pump is not designed for the increased heat consump- tion required when a building is being dried out. The additional heat consumption should be met using special devices provided by the customer. If a building is to be dried out in autumn or win- ter, we recommend installing an additional heating element (available as an accessory).

In cooling operation the heat pump is suitable for temperatures ranging from +15 °C to +40 °C.

It can be used for silent and dynamic cooling. The minimum water temperature is +7 °C.

ATTENTION!

The device is not suitable for operation with a frequency converter.

2.2Operating Principle

Heating

Outside air is drawn in by the ventilator and fed via the evapora- tor (heat exchanger). The evaporator cools the air, i.e. it extracts heat from it. This extracted heat is then transferred to the working medium (refrigerant) in the evaporator.

The heat is “pumped” to a higher temperature level by increasing its pressure with the aid of an electrically driven compressor. It is then transferred to the heating water using the liquifier (heat ex- changer).

Electrical energy is used to raise the temperature of the heat in the environment to a higher level. Because the energy extracted from the air is transferred to the heating water, this type of device is called an air-to-water heat pump.

The air-to-water heat pump consists of the main components evaporator, ventilator and expansion valve, as well as the low- noise compressor, liquifier and electrical control system.

At low ambient temperatures, humidity accumulates on the evap- orator in the form of frost reducing the transfer of heat. The evap- orator is defrosted automatically by the heat pump as required. Steam may be emitted from the air outlet depending on the at- mospheric conditions.

3 Scope of Delivery

3.1Basic Device

The compact heat pump is supplied complete with all of the im- portant components of the heating circulation system:

„Expansion vessel

„Heat circulating pump

„Overflow valve and safety components (pressure relief valve, pressure gauge)

R404A is used as the refrigerant.

























1)Evaporator (heating operation)

2)Ventilator

3)24 l expansion vessel

4)Switch box

5)Liquifier (heating operation)

6)Compressor

7)Overflow valve

8)Heat circulating pump

9)Buffer tank

10)Filter dryer

11)Inspection window

12)Expansion valve

Cooling

The functions of the evaporator and the liquifier are reversed in the “Cooling” operating mode.

The heating water transfers its heat to the refrigerant via the liq- uifier which is now functioning as an evaporator. The compressor raises the temperature level of the refrigerant and the heat is passed on to the surrounding air via the liquifier (functioning as an evaporator in heating operation).

E-3

Image 4
Contents LIK 8MER Table of contents Please Read Immediately Important InformationLegal Regulations Directives Energy-Efficient Use Heat PumpPurpose of the Heat Pump Scope of DeliveryApplication Operating PrincipleAccessories Pack Switch BoxTransport Installation Set-UPHeating System Connection Electrical ConnectionStart-UP Start-Up ProcedurePreparation Faults / Trouble- Shooting Maintenance / CleaningDecommissioning/ Disposal Device Information Type and order code DesignMaßbilder / Dimension Drawings / Schémas cotés Anhang / Appendix / AnnexesDrawings Maßbilder / DimensionSchémas cotés Einbaumaße / Installation Dimensions / Cotes de montage AnhangDiagramme / Diagrams / Diagrammes Heizbetrieb / Heating Operation / Mode chauffageKühlbetrieb / Cooling Operation / Mode refroidissement HGLQJXQJHQÂ&RQGLWLRQVÂ&RQGLWLRQVStromlaufpläne / Circuit Diagrams / Schémas électriques VII Last / Load / Charge Anhang · Appendix · Annexes HXFKWH +XPLGLW\ +XPLGLWp Gruppe K12 Elektron. Relais f. Schwimmbadwasserumwälz XII Darstellung / Schematic view / Représentation XiiiXIV Anhang · Appendix · Annexes

LIK 8MER specifications

The Dimplex LIK 8MER is a cutting-edge electric radiator that combines modern technology with stylish design. Designed to provide efficient warmth and comfort in residential settings, this heating solution stands out for its user-friendly features and high performance.

One of the main characteristics of the LIK 8MER is its advanced electronic control system, which promotes efficient energy usage. This system allows for precise temperature management, ensuring that your living space remains comfortable without excessive energy consumption. The radiator can be programmed to suit your lifestyle, with options to set different temperature levels for various times of the day or week.

The LIK 8MER is equipped with Dimplex’s unique Duo Heat technology, which enhances heat distribution throughout the room. This technology combines convection heating and thermal storage, allowing the radiator to store heat and release it gradually, ensuring consistent warmth. As a result, users experience a more stable and comfortable environment, devoid of the cold drafts often associated with traditional heating systems.

Another key feature of the Dimplex LIK 8MER is its sleek design. The radiator's minimalist aesthetic allows it to seamlessly integrate into any home décor, making it an attractive addition to both modern and traditional interiors. Available in various sizes, the LIK 8MER can easily fit in different spaces, whether it’s a living room, bedroom, or hallway.

In terms of safety, the LIK 8MER is designed with multiple features to ensure peace of mind for users. It includes overheat protection, which automatically turns off the radiator if it gets too hot, preventing any risk of fire. Furthermore, its surface temperature is kept at safe levels, making it suitable for homes with children or pets.

Additional technologies include a built-in timer and an intelligent learning function. The timer allows users to set the radiator to turn on or off according to their schedule, while the learning function adapts to the user’s habits, optimizing energy use based on past behavior.

Overall, the Dimplex LIK 8MER electric radiator is a perfect blend of technology, efficiency, and style. Its innovative features and thoughtful design make it a practical choice for anyone seeking to enhance their home heating experience. Whether you are aiming to save on energy bills or simply seeking reliable warmth, the LIK 8MER delivers on all fronts.