Dimplex LIK 8MER Maintenance / Cleaning, Faults / Trouble- Shooting, Decommissioning/ Disposal

Page 9

10

8 Maintenance / Cleaning

8.1Maintenance

To protect the paintwork, avoid leaning or putting objects on the device. External heat pump parts can be wiped with a damp cloth and domestic cleaner.

ATTENTION!

Never use cleaning agents containing sand, soda, acid or chloride as these can damage the surfaces.

To prevent faults due to sediment in the heat exchanger of the heat pump, ensure that the heat exchanger in the heating system can not be contaminated. We recommend protecting the evapo- rator by installing a bird guard in the inlet duct. At least 80 % of the cross section of the grating should be open. In the event that operating malfunctions due to contamination still occur, the sys- tem should be cleaned as described below.

8.2Cleaning the Heating System

The ingress of oxygen into the heating water circuit may result in the formation of oxidation products (rust), particularly if steel components are used. These products enter the heating system via the valves, the circulating pumps and/or plastic pipes. It is therefore essential - in particular with respect to the piping of un- derfloor heating systems - that only diffusion-proof materials are used.

ATTENTION!

We recommend the installation of a suitable corrosion protection system to prevent the formation of deposits (e.g. rust) in the condenser of the heat pump.

Residue from lubricants and sealants may also contaminate the heating water.

In the case of severe contamination leading to a reduction in the performance of the liquifier in the heat pump, the system must be cleaned by a heating technician.

According to today's state of knowledge, we recommend using a 5 % phosphoric acid solution for cleaning purposes. However, if cleaning needs to be performed more frequently, a 5 % formic acid solution should be used.

In either case, the cleaning fluid should be at room temperature. We recommend flushing the heat exchanger in the direction op- posite to the normal flow direction.

To prevent acidic cleaning agents from entering the heating sys- tem circuit, we recommend connecting the flushing device di- rectly to the flow and return flow of the liquifier of the heat pump.

It is important that the system be thoroughly flushed using appro- priate neutralising agents to prevent any damage from being caused by cleaning agent residue remaining in the system.

Acids must be used with great care and all relevant regulations of the employers' liability insurance associations must be adhered to.

If in doubt, contact the manufacturer of the chemicals!

The buffer tank is drained using the filling and drain cocks on the lower left of the device. Also open the ball valve on the pressure expansion vessel to vent the buffer tank.

8.3Cleaning the Air System

Air ducts, evaporator, ventilator and condensate outflow should be cleaned of contamination (leaves, twigs, etc.) before the heat- ing period. Do this by opening the left and front sides of the heat pump. The bottom should be opened first followed by the top.

ATTENTION!

Before opening the device, ensure that all circuits are isolated from the power supply.

Remove and rehang the side panel assemblies as described in Chapter 4.

To prevent the evaporator and the condensate tray from being damaged, do not use hard or sharp objects for cleaning.

9 Faults / Trouble- Shooting

This heat pump is a quality product and is designed for trouble- free and maintenance-free operation. In the event that a fault should occur, it will be shown on the heat pump manager display. Simply consult the Faults and Trouble-shooting page in the oper- ating instructions of the heat pump manager. If you cannot cor- rect the fault yourself, please contact your after-sales service technician.

ATTENTION!

Work on the heat pump may only be carried out by authorised and qualified after-sales service technicians.

10 Decommissioning/ Disposal

Before removing the heat pump, disconnect it from the power source and close all valves. Observe all environmentally-relevant requirements regarding the recovery, recycling and disposal of materials and components in accordance with all applicable standards. Particular attention should be paid to the proper dis- posal of refrigerants and refrigeration oils.

English

www.dimplex.de

E-8

Image 9
Contents LIK 8MER Table of contents Important Information Please Read ImmediatelyLegal Regulations Directives Energy-Efficient Use Heat PumpScope of Delivery Purpose of the Heat PumpApplication Operating PrincipleSwitch Box Accessories PackTransport Set-UP InstallationElectrical Connection Heating System ConnectionStart-Up Procedure Start-UPPreparation Maintenance / Cleaning Faults / Trouble- ShootingDecommissioning/ Disposal Type and order code Design Device InformationAnhang / Appendix / Annexes Maßbilder / Dimension Drawings / Schémas cotésMaßbilder / Dimension DrawingsSchémas cotés Anhang Einbaumaße / Installation Dimensions / Cotes de montageHeizbetrieb / Heating Operation / Mode chauffage Diagramme / Diagrams / DiagrammesHGLQJXQJHQÂ&RQGLWLRQVÂ&RQGLWLRQV Kühlbetrieb / Cooling Operation / Mode refroidissementStromlaufpläne / Circuit Diagrams / Schémas électriques VII Last / Load / Charge Anhang · Appendix · Annexes HXFKWH +XPLGLW\ +XPLGLWp Gruppe K12 Elektron. Relais f. Schwimmbadwasserumwälz XII Xiii Darstellung / Schematic view / ReprésentationXIV Anhang · Appendix · Annexes

LIK 8MER specifications

The Dimplex LIK 8MER is a cutting-edge electric radiator that combines modern technology with stylish design. Designed to provide efficient warmth and comfort in residential settings, this heating solution stands out for its user-friendly features and high performance.

One of the main characteristics of the LIK 8MER is its advanced electronic control system, which promotes efficient energy usage. This system allows for precise temperature management, ensuring that your living space remains comfortable without excessive energy consumption. The radiator can be programmed to suit your lifestyle, with options to set different temperature levels for various times of the day or week.

The LIK 8MER is equipped with Dimplex’s unique Duo Heat technology, which enhances heat distribution throughout the room. This technology combines convection heating and thermal storage, allowing the radiator to store heat and release it gradually, ensuring consistent warmth. As a result, users experience a more stable and comfortable environment, devoid of the cold drafts often associated with traditional heating systems.

Another key feature of the Dimplex LIK 8MER is its sleek design. The radiator's minimalist aesthetic allows it to seamlessly integrate into any home décor, making it an attractive addition to both modern and traditional interiors. Available in various sizes, the LIK 8MER can easily fit in different spaces, whether it’s a living room, bedroom, or hallway.

In terms of safety, the LIK 8MER is designed with multiple features to ensure peace of mind for users. It includes overheat protection, which automatically turns off the radiator if it gets too hot, preventing any risk of fire. Furthermore, its surface temperature is kept at safe levels, making it suitable for homes with children or pets.

Additional technologies include a built-in timer and an intelligent learning function. The timer allows users to set the radiator to turn on or off according to their schedule, while the learning function adapts to the user’s habits, optimizing energy use based on past behavior.

Overall, the Dimplex LIK 8MER electric radiator is a perfect blend of technology, efficiency, and style. Its innovative features and thoughtful design make it a practical choice for anyone seeking to enhance their home heating experience. Whether you are aiming to save on energy bills or simply seeking reliable warmth, the LIK 8MER delivers on all fronts.