2-9. Placing Jumper Links

Check input voltage available at site.

1 Jumper Link Label

Move jumper links to match input voltage and label on unit.

1

Do not overtighten.

Single-Phase Models

 

 

 

 

 

 

 

 

200 VOLTS

 

230 VOLTS

 

 

460 VOLTS

 

 

 

 

L

L

L

L

 

L

L

 

 

 

 

 

 

 

 

S-083 566-C

 

 

Three-Phase Models

 

 

 

 

 

 

 

 

 

230 Volts

 

 

460 Volts

 

575 Volts

L1

L2

L3

 

L1

L2

L3

L1

L2

L3

S-094 120-B

Tools Needed:

3/8 in

Ref. ST-801 455

OM-279 Page 12

Image 16
Contents Processes OM-279Description From Hobart to You Table of Contents Page Symbol Usage Marks a special safety messagePlasma Arc Cutting Hazards Cutting can cause fire or explosionFlying Sparks can cause injury ARC Rays can burn eyes and skinNoise can damage hearing Fumes and Gases can be hazardousPrincipal Safety Standards EMF Information About PacemakersSignification des symboles LE Coupage pré sente un risque de feu ou d’explosionUNE DÉ Charge É Lectrique peut entraîner la mort Identifie un message de sé curité particulierLE Bruit peut endommager l’ouïe LES Fumé ES ET LES GAZ peuvent ê tre dangereuxLE Plasma D’ARC peut entraîner des blessures LES Bouteilles peuvent exploser si elles sont endommagé esPrincipales normes de sé curité Information sur les champs é lectromagné tiques Consignes relatives aux stimulateurs cardiaquesDimensions And Weight SpecificationsDuty Cycle And Overheating Special installation may be Cutting SpeedSelecting a Location Movement Location And AirflowInstalling And Connecting Work Clamp Connecting Gas/Air SupplyElectrical Service Guide Placing Jumper Links Connecting Input Power Three-Phase SystemAlways connect Grounding conductor firstOperation Front Panel ControlsSetting Gas/Air Pressure Set pressure to 70 PSI 483 kPaExample Of Cutting Operation Sequence Of OperationTrigger is pressed Maintenance & Troubleshooting Trouble Lights Checking Shield Cup Shutdown SystemTroubleshooting Running slowlyFan motor FM does not run Power light Electrical Diagrams Circuit Diagram For 230/460/575 Volt Models OM-279 Parts List Dia Part Mkgs Description Quantity Dia Part OM-279 OM-279 Page Page Service SupportContact your Distributor for Hobart Welding Products