3-2. Setting Gas/Air Pressure

Place controls in positions shown to adjust air pressure. Only gas/air cir- cuit is activated when the Power switch is turned On with Output Control in Gas/Air Set position.

1 Pressure Gauge

2 Pressure Adjustment Knob

Lift knob and turn to adjust pres- sure. Push knob down to lock in set- ting. Place output control in desired cutting output.

Set pressure to 70 PSI (483 kPa).

2

1

Requires 70–150 PSI

(483–1034 kPa) Supply

Select Desired

Set Controls Turn On Gas/Air Supply Adjust Pressure Amperage To Begin Cutting

Ref. ST-190 676 / Ref. ST-801 454-B

OM-279 Page 15

Image 19
Contents Processes OM-279Description From Hobart to You Table of Contents Page Cutting can cause fire or explosion Symbol UsageMarks a special safety message Plasma Arc Cutting HazardsFumes and Gases can be hazardous Flying Sparks can cause injuryARC Rays can burn eyes and skin Noise can damage hearingPrincipal Safety Standards About Pacemakers EMF InformationIdentifie un message de sé curité particulier Signification des symbolesLE Coupage pré sente un risque de feu ou d’explosion UNE DÉ Charge É Lectrique peut entraîner la mortLES Bouteilles peuvent exploser si elles sont endommagé es LE Bruit peut endommager l’ouïeLES Fumé ES ET LES GAZ peuvent ê tre dangereux LE Plasma D’ARC peut entraîner des blessuresPrincipales normes de sé curité Consignes relatives aux stimulateurs cardiaques Information sur les champs é lectromagné tiquesDimensions And Weight SpecificationsDuty Cycle And Overheating Movement Location And Airflow Special installation may beCutting Speed Selecting a LocationInstalling And Connecting Work Clamp Connecting Gas/Air SupplyElectrical Service Guide Placing Jumper Links Grounding conductor first Connecting Input PowerThree-Phase System Always connectFront Panel Controls OperationSet pressure to 70 PSI 483 kPa Setting Gas/Air PressureExample Of Cutting Operation Sequence Of OperationTrigger is pressed Maintenance & Troubleshooting Checking Shield Cup Shutdown System Trouble LightsRunning slowly TroubleshootingFan motor FM does not run Power light Electrical Diagrams Circuit Diagram For 230/460/575 Volt Models OM-279 Parts List Dia Part Mkgs Description Quantity Dia Part OM-279 OM-279 Page Page Support ServiceHobart Welding Products Contact your Distributor for