Hobart Welding Products OM-2208 manual Meter Functions For CC/CV Model

Page 22

4-3. Meter Functions For CC/CV Model

NOTE

The meters display the actual weld output values for approximately three seconds after the arc is broken.

Mode

 

Meter Reading At Idle

 

Meter Reading While Welding

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

Scratch

 

80.0

 

 

85

 

 

10.3

 

 

85

 

Start TIG

 

 

 

 

 

 

 

 

 

Actual Volts (OCV)

Preset Amps

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

Lift-Arc TIG

 

7.0

 

 

85

 

 

10.3

 

 

85

 

 

 

Actual Volts

Preset Amps

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

TIG

 

 

 

 

85

 

 

10.3

 

 

85

 

 

 

Blank

Preset Amps

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

MIG

 

24.5

 

 

 

 

 

24.5

 

 

250

 

 

 

Preset Volts

 

Blank

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

Pulsed

 

PPP

 

 

PPP

 

 

24.5

 

 

250

 

MIG

 

 

 

 

 

 

 

 

 

Pulse Display

Pulse Display

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

CC

 

 

 

 

85

 

 

24.5

 

 

85

 

 

 

Blank

Preset Amps

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

Stick

 

80.0

 

 

85

 

 

24.5

 

 

85

 

 

Actual Volts (OCV)

Preset Amps

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

V-Sense

 

80.0

 

 

 

 

 

24.5

 

 

250

 

Feeder

 

 

 

 

 

 

 

 

 

 

Flashes OCV And Preset

 

Blank

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

4-4. Mode Switch Settings For CC/CV Model

NOTE

The Stick and CC modes provide the Adaptive Hot Startfeature, which automatically increases the output amperage at the start of a weld should the start require it. This eliminates electrode sticking at arc start.

Mode Switch Setting

Process

Output On/Off Control

 

 

 

Scratch Start TIG

GTAW

Electrode Hot

 

 

 

Lift-Arc TIG

GTAW – See Section 4-7

Electrode Hot

 

 

 

TIG

GTAW With HF Unit, Pulsing Device, Or Remote Control

At Remote 14

 

 

 

MIG

GMAW

At Remote 14

 

 

 

Pulsed MIG

GMAW-P (Requires an external pulsing device.)

At Remote 14

 

 

 

CC

Stick (SMAW) With Remote On/Off

At Remote 14

 

 

 

Stick

SMAW

Electrode Hot

 

 

 

V-Sense Feeder

MIG (GMAW) With Voltage Sensing Wire Feeder

Electrode Hot

 

 

 

OM-2208 Page 18

Image 22
Contents Processes OM-2208Description From Hobart to You Table of Contents Page Arc Welding Hazards Symbol UsageMarks a special safety message Electric Shock can killFlying Metal can injure eyes ARC Rays can burn eyes and skinWelding can cause fire or explosion Buildup of GAS can injure or killPrincipal Safety Standards EMF Information About PacemakersUN Choc É Lectrique peut tuer Signification des symbolesConsignes DE Securite Lire Avant Utilisation LES Fumé ES ET LES GAZ peuvent ê tre dangereuxDES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer un incendie ou une explosionLE Bruit peut affecter l’ouïe ’EMPLOI Excessif peut Risque D’INCENDIE OULA Chute DE L’APPAREIL peut blesser DES Organes Mobiles peuvent provoquer des blessuresInformation sur les champs é lectromagné tiques Principales normes de sé curitéConsignes relatives aux stimulateurs cardiaques Introduction SpecificationsDuty Cycle And Overheating CV Mode CC ModeVolt-Ampere Curves Movement Do not move or operate unit where it could tip InstallationDimensions And Weight Selecting a Location45 m 60 m 70 m 90 m 105 m 120 m Weld Output Receptacles And Selecting Cable SizesARC Welding can cause Electromagnetic Interference Put terminalsRemote 14 Receptacle Information Socket InformationInput Voltage Electrical Service GuideHz Three Phase Hz Single Min Grounding Conductor Size In AWG/KcmilConnecting Input Power For single-phase operationOperation Front Panel Controls For CC/CV ModelFront Panel Controls For CC Model Mode Switch Setting Process Output On/Off Control Mode Switch Settings For CC/CV ModelMode Meter Reading At Idle Meter Reading While Welding Meter Functions For CC/CV ModelMode Switch Settings For CC Model Meter Functions For CC ModelMaintenance & Troubleshooting Lift-Arc TIG ProcedureHE.L P-9 Voltmeter/Ammeter Help DisplaysDo not remove case when blowing out inside of unit TroubleshootingBlowing Out Inside Of Unit OM-2208 Electrical Diagrams Circuit Diagram For 230/460 Volt ModelsCircuit Diagram For 460/575 Volt Models Parts List Parts AssemblyItem Dia Part Description Mkgs Quantity Dia Part Description Mkgs Quantity OM-2208 OM-2208 Service SupportContact your Distributor for Hobart Welding Products