Hobart Welding Products OM-2208 Electrical Service Guide, Hz Three Phase Hz Single, Input Voltage

Page 18

3-5. Electrical Service Guide

YCAUTION: INCORRECT INPUT POWER can damage this welding power source. This welding pow- er source requires a CONTINUOUS supply of 60 Hz (+10%) power at +10% of rated input voltage. Do not use a generator with automatic idle device (that idles engine when no load is sensed) to supply input power to this welding power source.

NOTE

Actual input voltage should not exceed ± 10% of indicated required input voltage. If actual input voltage is outside of this range, output may not be available.

 

60 Hz Three Phase

60 Hz Single

 

 

Phase

 

 

 

 

 

 

 

 

 

 

 

 

Input Voltage

230

460

575

230

 

460

 

 

 

 

 

 

 

Input Amperes At Rated Output

31

15

12

53

 

27

 

 

 

 

 

 

 

Max Recommended Standard Fuse Rating In Amperes 1

 

 

 

 

 

 

Time-Delay 2

35

15

15

60

 

30

Normal Operating 3

45

20

20

80

 

40

 

 

 

 

 

 

 

Min Input Conductor Size In AWG/Kcmil

10

14

14

8

 

10

 

 

 

 

 

 

 

Max Recommended Input Conductor Length In Feet (Meters)

112

175

274

85

 

224

(34)

(53)

(83)

(26)

 

(68)

 

 

 

 

 

 

 

 

 

Min Grounding Conductor Size In AWG/Kcmil

10

14

14

8

 

10

 

 

 

 

 

 

 

Reference: 1999 National Electrical Code (NEC)

1Consult factory for circuit breaker applications.

2“Time-Delay” fuses are UL class “RK5” .

3“Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and above).

Notes

OM-2208 Page 14

Image 18
Contents OM-2208 ProcessesDescription From Hobart to You Table of Contents Page Arc Welding Hazards Symbol UsageMarks a special safety message Electric Shock can killFlying Metal can injure eyes ARC Rays can burn eyes and skinWelding can cause fire or explosion Buildup of GAS can injure or killPrincipal Safety Standards EMF Information About PacemakersUN Choc É Lectrique peut tuer Signification des symbolesConsignes DE Securite Lire Avant Utilisation LES Fumé ES ET LES GAZ peuvent ê tre dangereuxLE Soudage peut provoquer un incendie ou une explosion DES Particules Volantes peuvent blesser les yeuxLE Bruit peut affecter l’ouïe ’EMPLOI Excessif peut Risque D’INCENDIE OULA Chute DE L’APPAREIL peut blesser DES Organes Mobiles peuvent provoquer des blessuresPrincipales normes de sé curité Information sur les champs é lectromagné tiquesConsignes relatives aux stimulateurs cardiaques Specifications IntroductionDuty Cycle And Overheating CC Mode CV ModeVolt-Ampere Curves Movement Do not move or operate unit where it could tip InstallationDimensions And Weight Selecting a Location45 m 60 m 70 m 90 m 105 m 120 m Weld Output Receptacles And Selecting Cable SizesARC Welding can cause Electromagnetic Interference Put terminalsRemote 14 Receptacle Information Socket InformationInput Voltage Electrical Service GuideHz Three Phase Hz Single Min Grounding Conductor Size In AWG/KcmilConnecting Input Power For single-phase operationOperation Front Panel Controls For CC/CV ModelFront Panel Controls For CC Model Mode Switch Setting Process Output On/Off Control Mode Switch Settings For CC/CV ModelMode Meter Reading At Idle Meter Reading While Welding Meter Functions For CC/CV ModelMode Switch Settings For CC Model Meter Functions For CC ModelMaintenance & Troubleshooting Lift-Arc TIG ProcedureHE.L P-9 Voltmeter/Ammeter Help DisplaysTroubleshooting Do not remove case when blowing out inside of unitBlowing Out Inside Of Unit OM-2208 Electrical Diagrams Circuit Diagram For 230/460 Volt ModelsCircuit Diagram For 460/575 Volt Models Parts List Parts AssemblyItem Dia Part Description Mkgs Quantity Dia Part Description Mkgs Quantity OM-2208 OM-2208 Service SupportContact your Distributor for Hobart Welding Products