Hobart Welding Products OM-2208 Weld Output Receptacles And Selecting Cable Sizes, Put terminals

Page 16

3-2. Weld Output Receptacles And Selecting Cable Sizes

Y ARC WELDING can cause Electromagnetic Interference.

To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor. Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving the welding machine, using shielded cables, using line filters, or shielding the work area.

 

 

 

 

 

Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit

 

 

 

 

 

 

 

 

 

 

 

 

Not Exceeding***

 

 

 

 

 

 

 

 

 

100 ft (30 m) or Less

150 ft

200 ft

250 ft

300 ft

 

350 ft

400 ft

 

 

 

 

 

(45 m)

(60 m)

(70 m)

(90 m)

 

(105 m)

(120 m)

 

 

 

 

 

 

 

 

 

Weld Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminals

 

 

 

 

 

 

 

 

 

 

Y Turn off power before

Welding

10 – 60%

60 – 100%

 

 

 

 

 

 

 

connecting to weld out-

Duty

Duty

 

10 – 100% Duty Cycle

 

 

put terminals.

Amperes

 

 

 

Cycle

Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YDo not use worn, dam- aged, undersized, or poorly spliced cables.

 

 

100

4 (20)

4 (20)

4 (20)

3 (30)

2 (35)

1 (50)

1/0 (60)

1/0 (60)

 

 

150

3 (30)

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

3/0 (95)

 

 

200

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

4/0 (120)

 

 

250

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 2/0

 

 

(2x70)

(2x70)

 

 

 

 

 

 

 

 

 

 

 

300

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 3/0

2 ea. 3/0

 

 

(2x70)

(2x95)

(2x95)

 

 

 

 

 

 

 

 

 

 

350

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 3/0

2 ea. 3/0

2 ea. 4/0

 

 

(2x70)

(2x95)

(2x95)

(2x120)

 

 

 

 

 

 

 

+

400

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 3/0

2 ea. 4/0

2 ea. 4/0

 

(2x70)

(2x95)

(2x120)

(2x120)

Output Receptacles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 3/0

2 ea. 4/0

3 ea. 3/0

3 ea. 3/0

 

 

(2x70)

(2x95)

(2x120)

(3x95)

(3x95)

 

 

 

 

 

 

 

 

600

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 3/0

2 ea. 4/0

3 ea. 3/0

3 ea. 4/0

3 ea. 4/0

 

 

(2x70)

(2x95)

(2x120)

(3x95)

(3x120)

(3x120)

 

 

 

 

 

*This chart is a general guideline and may not suit all applications. If cable overheating occurs (normally you can smell it), use next size larger cable.

**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

 

( ) = mm2 for metric use

S-0007-E–

***For distances longer than those shown in this guide, call a factory applications representative at 920-735-4505.

OM-2208 Page 12

Image 16
Contents Processes OM-2208Description From Hobart to You Table of Contents Page Symbol Usage Marks a special safety messageArc Welding Hazards Electric Shock can killARC Rays can burn eyes and skin Welding can cause fire or explosionFlying Metal can injure eyes Buildup of GAS can injure or killPrincipal Safety Standards EMF Information About PacemakersSignification des symboles Consignes DE Securite Lire Avant UtilisationUN Choc É Lectrique peut tuer LES Fumé ES ET LES GAZ peuvent ê tre dangereuxDES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer un incendie ou une explosionLE Bruit peut affecter l’ouïe Risque D’INCENDIE OU LA Chute DE L’APPAREIL peut blesser’EMPLOI Excessif peut DES Organes Mobiles peuvent provoquer des blessuresInformation sur les champs é lectromagné tiques Principales normes de sé curitéConsignes relatives aux stimulateurs cardiaques Introduction SpecificationsDuty Cycle And Overheating CV Mode CC ModeVolt-Ampere Curves Installation Dimensions And WeightMovement Do not move or operate unit where it could tip Selecting a LocationWeld Output Receptacles And Selecting Cable Sizes ARC Welding can cause Electromagnetic Interference45 m 60 m 70 m 90 m 105 m 120 m Put terminalsRemote 14 Receptacle Information Socket InformationElectrical Service Guide Hz Three Phase Hz SingleInput Voltage Min Grounding Conductor Size In AWG/KcmilConnecting Input Power For single-phase operationOperation Front Panel Controls For CC/CV ModelFront Panel Controls For CC Model Mode Switch Settings For CC/CV Model Mode Meter Reading At Idle Meter Reading While WeldingMode Switch Setting Process Output On/Off Control Meter Functions For CC/CV ModelMode Switch Settings For CC Model Meter Functions For CC ModelMaintenance & Troubleshooting Lift-Arc TIG ProcedureHE.L P-9 Voltmeter/Ammeter Help DisplaysDo not remove case when blowing out inside of unit TroubleshootingBlowing Out Inside Of Unit OM-2208 Electrical Diagrams Circuit Diagram For 230/460 Volt ModelsCircuit Diagram For 460/575 Volt Models Parts List Parts AssemblyItem Dia Part Description Mkgs Quantity Dia Part Description Mkgs Quantity OM-2208 OM-2208 Service SupportContact your Distributor for Hobart Welding Products