Dimplex 190, LI 11TER+, Heat Pump, LI 16TER+ manual Device Information, Type and order code Design

Page 10

11

11 Device Information

1Type and order code

2Design

2.1Model

2.2Degree of protection according to EN 60 529 for compact devices and heating components

2.3Installation Location

3

Performance data

 

3.1

Operating temperature limits:

 

 

 

 

 

Heating water flow/return flow 1

°C / °C

 

Cooling, flow

°C

 

 

 

 

Air (heating)

°C

 

Air (cooling)

°C

3.2Temperature spread of heating water at A7 / W35

3.3

Heat output / COP

at A-7 / W352

kW / ---

 

 

at A-7 / W452

kW / ---

 

 

at A2

/ W35 2

kW / ---

 

 

at A7

/ W35

2

kW / ---

 

 

at A7

/ W45

2

kW / ---

 

 

at A10 / W35 2

kW / ---

3.4

Temperature spread of cooling water at A35 / W7

 

3.5

Cooling capacity / COP

at A27 / W7

 

kW / ---

 

 

at A27

/ W18

kW / ---

 

 

at A35

/ W7

 

kW / ---

 

 

at A35

/ W18

kW / ---

 

 

 

 

 

 

 

3.6

Sound power level

 

 

 

 

dB(A)

3.7

Sound pressure level at a distance of 1 m (indoors)

dB(A)

3.8Heating water flow with an internal pressure differential of m³/h / Pa

3.9Cooling water flow with an internal pressure differential of m³/h / Pa

3.10

Air flow rate with an external static pressure differentia

m³/h / Pa

 

 

m³/h / Pa

 

 

 

3.11

Refrigerant; total filling weight

type / kg

4

Dimensions, connections and weight

 

 

 

 

4.1

Device dimensions

H x W x L cm

4.2

Device connections to heating system

Inch

4.3Device connections to additional heat exchanger

 

(waste heat recovery)

 

Inch

4.4

Air duct inlet and outlet (min. internal dimensions)

L x W cm

 

 

 

4.5

Weight of the transportable unit(s) incl. packing

kg

5

Electrical connection

 

 

 

 

 

 

5.1

Nominal voltage; fuse protection

 

V / A

5.2

Nominal power consumption 2

A2 W35

kW

5.3

Starting current with soft starter

 

A

5.4

Nominal current A2 W35 / cos ϕ

 

A / ---

6Complies with the European safety regulations

7Additional model features

7.1Defrosting

Type of defrosting Defrosting tray included

7.2Heating water in device protected against freezing

7.3Performance levels

7.4Controller internal/external

LI 11TER+

Reversible

IP 21

Indoors

Up to 58 / above 18

+7 to +20 -25 to +35 +15 to +40

9.7

 

5.0

7.1 / 2.9

 

6.6 / 2.7

 

 

6.4 / 2.3

8.8 / 3.2

 

8.8 / 3.1

11.3 / 3.8

 

11.3 / 3.6

 

 

9.6 / 3.1

12.2 / 4.1

 

12.1 / 3.9

6.5

 

5.0

8.8 / 2.8

 

8.8 / 2.8

10.9 / 3.3

 

10.8 / 3.2

7.6 / 2.1

 

7.5 / 2.1

9.5 / 2.5

 

9.5 / 2.5

 

55 / 61

 

50

1.0 / 3000

 

 

1.9 / 10900

1.0 / 3000

 

1.3 / 5900

 

 

 

4200 / 0

2500 / 25

R404A / 5.1

136 x 75 x 88

G 1 1/4'' external G 1 1/4'' external

50 x 50

222

400 / 16

2.742.86

 

23

4.9 / 0.8

 

 

5.16 / 0.8

 

3

Automatic

Reverse cycle Yes (heated)

Yes4

1

Internal

LI 16TER+

Reversible

IP 21

Indoors

Up to 58 / above 18

+7 to +20 -25 to +35

+15 to +40

.9..3

 

5..0

10.6 / 3.0

 

10.5 / 2.9

 

 

9.9 / 2.5

12.8 / 3.4

 

12.7 / 3.2

15.1 / 3.8

 

14.9 / 3.6

 

 

14.7 / 3.3

16.7 / 4.1

 

16.6 / 3.9

6.6

 

5.0

12.6 / 2.6

 

12.5 / 2.6

16.4 / 2.8

 

16.4 / 2.8

10.7 / 2.0

 

10.6 / 2.0

14.3 / 2.3

 

14.3 / 2.2

 

57 / 62

 

52

1.4 / 4500

 

 

2.6 / 14600

1.4 / 4500

 

1.8 / 7000

 

 

 

5200 / 0

4000 / 25

R404A / 5.7

157 x 75 x 88

G 1 1/4'' external

G 1 1/4'' external

57 x 57

260

400 / 20

3.84.0

 

25

6.9 / 0.8

 

7.2 / 0.8

 

3

 

 

 

Automatic

Reverse cycle

Yes (heated)

Yes4

1

Internal

English

1.See operating limits diagram

2.This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: 2 °C external air temperature and 55 °C heating water flow temperature.

3.See CE declaration of conformity

4.The heat circulating pump and the heat pump controller must always be ready for operation.

www.dimplex.de

E-9

Image 10
Contents LI 11TER+ LI 16TER+ Table of contents Please Read Immediately Purpose of the Heat PumpOperating Principle Scope of DeliveryBasic Device Transport Switch BoxHeat Pump Controller Installation Set-upHeating and Hot Water Connection Electrical ConnectionStart-up ProcedurePreparation Faults / Trouble- Shooting Maintenance / CleaningDecommissioning/ Disposal Device Information Type and order code DesignMaßbilder / Dimension Drawings / Schémas cotés Anhang / Appendix / AnnexesMaßbilder / Dimension Drawings / Schémas cotés Maßbild / Dimension Drawing / Schéma coté LI 11TER+16TER+ XIWULFKWXQJDiagramme / Diagrams / Diagrammes Heizbetrieb / Heating Operation / Mode chauffage LI 11TER+KOOHLVWXQJLQN@ Heizbetrieb / Heating Operation / Mode chauffage LI 16TER+ +HDWLQJFDSDFLW\LQN@VII Stromlaufpläne / Circuit Diagrams / Schémas électriques Anhang · Appendix · Annexes Last / Load / Charge Anhang · Appendix · Annexes XII Xiii Darstellung / Schematic View / Représentation XIVAnhang · Appendix · Annexes XVI

LI 16TER+, 190, Heat Pump, LI 11TER+ specifications

Dimplex Heat Pumps are designed to provide efficient and sustainable heating solutions for residential and commercial applications. The Dimplex models 190, LI 11TER+, and LI 16TER+ exemplify advanced heating technologies, featuring innovative designs that deliver optimal performance and energy efficiency.

The Dimplex 190 is particularly notable for its compact and versatile nature. This model operates on the principle of air source heat pumps, extracting heat from the ambient air and transferring it into the living space. It boasts a high coefficient of performance (COP), making it a cost-effective choice for homeowners looking to reduce their energy bills while maintaining a comfortable indoor environment. The Dimplex 190 is also equipped with an intuitive control system that allows for easy adjustments to the temperature settings, enhancing user convenience.

Moving on to the LI 11TER+ and LI 16TER+, these heat pumps are engineered for improved performance and reliability. One of their standout characteristics is the advanced inverter technology, which enables the unit to adjust its output according to the heating demand. This flexibility provides not only enhanced comfort but also significant energy savings compared to traditional heating systems. Additionally, both models are designed with noise reduction features, ensuring quiet operation that won’t disturb the tranquility of home life.

Another essential feature of the LI series is its enhanced heating capacity, particularly beneficial for larger spaces. The units are constructed with durable materials designed to withstand various weather conditions, ensuring longevity and performance even in challenging environments. The LI 11TER+ offers a heating capacity suitable for smaller to medium-sized homes, while the LI 16TER+ caters to more extensive residential spaces or commercial applications, providing tailored heating solutions for diverse needs.

In terms of sustainability, all Dimplex heat pumps use environmentally friendly refrigerants, contributing to lower carbon emissions. The integration of smart technology allows for compatibility with home automation systems, giving users the ability to monitor and control their heating remotely.

Overall, Dimplex Heat Pumps, including the 190, LI 11TER+, and LI 16TER+, stand out in the market for their combination of efficiency, advanced technology, and user-friendly features, making them an excellent choice for anyone seeking modern heating solutions that prioritize comfort and sustainability.