6.3

 



 



 







 



 

0  [ 

English

 

 

PD[  PD[ 

 

 

 

PL

 

 

PL

Q

 

 

Q



 

 

 



 

 



 

 



 

 



 

 

 



 

The values in parentheses are valid for the LI 16TER+

6.3Heating and Hot Water

Connection

The heating system connections on the heat pump have a 1" ex- ternal thread. Use a spanner to firmly grip the transitions when connecting the heat pump.

Before connecting the heating water system to the heat pump, the heating system must be flushed to remove any impurities, residue from sealants, etc. Any accumulation of deposits in the liquifier could cause the heat pump to completely break down. For systems in which the heating water flow can be shut off via the radiator or thermostat valves, an overflow valve must be in- stalled by the customer in a heating bypass downstream from the heat pump. This ensures a minimum heating water flow rate through the heat pump and helps to avoid faults.

Once the heating system has been installed, it must be filled, de- aerated and pressure-tested.

Minimum heating water flow rate

The minimum heating water flow rate through the heat pump must be assured in all operating states of the heating system. This can be accomplished, for example, by installing either a manifold without differential pressure or an overflow valve. The procedure for adjusting an overflow valve is described in the Chapter Start-up.

Antifreeze

A method of manual drainage (see illustration) should be pro- vided for heat pumps which are exposed to frost. The antifreeze function of the heat pump controller is active whenever the con- troller and the heat circulating pump are ready for operation. If the heat pump is taken out of service or in the event of a power failure, the system has to be drained. The heating circuit should be operated with a suitable antifreeze if heat pump systems are implemented in buildings where a power failure can not be de- tected (holiday home).

6.4Electrical Connection

The power supply and control voltage are supplied using stand- ard cables (load: 4-core, control: 3-core).

An all-pole disconnecting device with a contact gap of at least 3 mm (e.g. utility blocking contactor or power contactor) as well as a 3-pole circuit breaker with common tripping for all external conductors must be installed in the power supply (tripping current in compliance with the Device Information).

Ensure that the incoming supply has a clockwise rotating field when connecting multiphase devices L1; L2; L3.

ATTENTION!

Ensure that there is a clockwise rotating field: Operating the compressor in the wrong rotational direction could cause damage to the compressor.

The control voltage must be protected by a 10 A fuse.

For detailed information, see Circuit Diagrams in the Appendix.

E-6

Image 7
Contents LI 11TER+ LI 16TER+ Table of contents Purpose of the Heat Pump Please Read ImmediatelyOperating Principle Scope of DeliveryBasic Device Transport Switch BoxHeat Pump Controller Set-up InstallationElectrical Connection Heating and Hot Water ConnectionStart-up ProcedurePreparation Faults / Trouble- Shooting Maintenance / CleaningDecommissioning/ Disposal Type and order code Design Device InformationAnhang / Appendix / Annexes Maßbilder / Dimension Drawings / Schémas cotésMaßbild / Dimension Drawing / Schéma coté LI 11TER+ Maßbilder / Dimension Drawings / Schémas cotésXIWULFKWXQJ 16TER+Heizbetrieb / Heating Operation / Mode chauffage LI 11TER+ Diagramme / Diagrams / DiagrammesKOOHLVWXQJLQN@ +HDWLQJFDSDFLW\LQN@ Heizbetrieb / Heating Operation / Mode chauffage LI 16TER+VII Stromlaufpläne / Circuit Diagrams / Schémas électriques Anhang · Appendix · Annexes Last / Load / Charge Anhang · Appendix · Annexes XII Xiii XIV Darstellung / Schematic View / ReprésentationAnhang · Appendix · Annexes XVI

LI 16TER+, 190, Heat Pump, LI 11TER+ specifications

Dimplex Heat Pumps are designed to provide efficient and sustainable heating solutions for residential and commercial applications. The Dimplex models 190, LI 11TER+, and LI 16TER+ exemplify advanced heating technologies, featuring innovative designs that deliver optimal performance and energy efficiency.

The Dimplex 190 is particularly notable for its compact and versatile nature. This model operates on the principle of air source heat pumps, extracting heat from the ambient air and transferring it into the living space. It boasts a high coefficient of performance (COP), making it a cost-effective choice for homeowners looking to reduce their energy bills while maintaining a comfortable indoor environment. The Dimplex 190 is also equipped with an intuitive control system that allows for easy adjustments to the temperature settings, enhancing user convenience.

Moving on to the LI 11TER+ and LI 16TER+, these heat pumps are engineered for improved performance and reliability. One of their standout characteristics is the advanced inverter technology, which enables the unit to adjust its output according to the heating demand. This flexibility provides not only enhanced comfort but also significant energy savings compared to traditional heating systems. Additionally, both models are designed with noise reduction features, ensuring quiet operation that won’t disturb the tranquility of home life.

Another essential feature of the LI series is its enhanced heating capacity, particularly beneficial for larger spaces. The units are constructed with durable materials designed to withstand various weather conditions, ensuring longevity and performance even in challenging environments. The LI 11TER+ offers a heating capacity suitable for smaller to medium-sized homes, while the LI 16TER+ caters to more extensive residential spaces or commercial applications, providing tailored heating solutions for diverse needs.

In terms of sustainability, all Dimplex heat pumps use environmentally friendly refrigerants, contributing to lower carbon emissions. The integration of smart technology allows for compatibility with home automation systems, giving users the ability to monitor and control their heating remotely.

Overall, Dimplex Heat Pumps, including the 190, LI 11TER+, and LI 16TER+, stand out in the market for their combination of efficiency, advanced technology, and user-friendly features, making them an excellent choice for anyone seeking modern heating solutions that prioritize comfort and sustainability.