SECTION 2 – INSTALLATION

2-1.

Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max.

 

Input at Rated Load Output,

 

 

 

 

 

Rated

Weld

 

 

50/60 Hz, Single-Phase

 

 

 

Model

 

Open-

 

 

 

KVA

KW

 

Weld

Output

 

 

 

 

 

 

 

 

 

 

Amperes At

 

 

Circuit

 

 

 

 

 

Output

Mode

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

200 V

220 V

230 V

380 V

415 V

460 V

575 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEMA Class II (40):

 

80 Volts

85

 

74

 

 

37

29

16.8

8.2

 

 

200 Amperes, 28

AC

 

 

 

 

 

Volts AC, 40% Duty

AC

(4.6)*

 

(4)*

 

 

(2)*

(1.6)*

(0.91)*

(0.58)*

 

 

 

 

 

 

 

 

Cycle

 

 

 

 

 

 

 

 

 

 

 

60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEMA Class II (50):

CC

68 Volts

105

 

91

 

 

46

36

20.9

13.6

 

 

 

 

 

 

 

DC

(4.6)*

 

(4)*

 

 

(2)*

(1.6)*

(0.91)*

(0.58)*

 

 

300 Amperes, 32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Volts DC, 50% Duty

CV

40 Volts

103

 

90

 

 

45

36

20.7

13.6

 

 

Cycle

 

 

 

 

 

DC

(7)*

 

(6.2)*

 

 

(3.1)*

(2.5)*

(1.4)*

(0.74)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEMA Class II (40):

 

80 Volts

 

71

 

41

37

 

 

15.7

7.9

 

 

200 Amperes, 28

AC

 

 

 

 

 

 

Volts AC, 40% Duty

AC

 

(4.7)*

 

(2.7)*

(2.5)*

 

 

(1.0)*

(0.5)*

 

 

 

 

 

 

 

 

 

Cycle

 

 

 

 

 

 

 

 

 

 

 

50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEMA Class II (50):

CC

57 Volts

 

90

 

52

48

 

 

19.3

13.1

 

 

 

 

 

 

 

 

DC

 

(4.7)*

 

(4.7)*

(2.5)*

 

 

(1.0)*

(0.5)*

 

 

300 Amperes, 32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Volts DC, 50% Duty

CV

40 Volts

 

98

 

57

52

 

 

21.6

13.5

 

 

Cycle

 

 

 

 

 

 

DC

 

(6.2)*

 

(3.6)*

(3.3)*

 

 

(1.4)*

(0.73)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*While idling.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-2. Volt-Ampere Curves

A. AC Mode

Volt-ampere curves show mini- mum and maximum voltage and amperage output capabilities of unit. Curves of other settings fall be- tween curves shown.

B. CC Mode DC

C. CV Mode DC

va_curve1 4/95 – ST-127 201 / ST-127 198 / ST-127 197

OM-318 Page 9

Image 13
Contents Processes OM-318Description From Hobart to You Table of Contents Page Marks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killPrincipal Safety Standards About Pacemakers EMF InformationConsignes DE Securite Lire Avant Utilisation Signification des symbolesUN Choc É Lectrique peut tuer LES Fumé ES ET LES GAZ peuvent ê tre dangereuxDES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer un incendie ou une explosionLE Bruit peut affecter l’ouïe LA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU’EMPLOI Excessif peut DES Organes Mobiles peuvent provoquer des blessuresInformation sur les champs é lectromagné tiques Principales normes de sé curitéConsignes relatives aux stimulateurs cardiaques Specifications InstallationAC Mode CC Mode DC CV Mode DCDuty Cycle And Overheating DC Mode CV or CCDimensions Dimensions And WeightsWeight Selecting a LocationRemote 14 Receptacle Weld Output Terminals And Selecting Cable SizesWeld Output Welding 10 60% 60 100% 10 100% Duty Cycle CycleVolts AC Duplex Receptacle Electrical Service Guide60 Hz 50 Hz Special installation may be Placing Jumper Links And Connecting Input PowerSection Controls OperationRoutine Maintenance Maintenance & TroubleshootingDisconnect power before maintaining MonthsTrouble Remedy TroubleshootingOM-318 Circuit Diagram Electrical DiagramMain Assembly Parts ListPLG51 Panel, Front w/Components Panel, Front w/Components -1 Item Rectifier, Si Diode -1 Item 126Page Page Support ServiceHobart Welding Products Contact your Distributor for