2-6. Weld Output Terminals And Selecting Cable Sizes
|
|
|
| Total Cable (Copper) Length In Weld Circuit Not Exceeding |
| ||||||
|
|
| 100 ft (30 m) Or Less | 150 ft | 200 ft | 250 ft | 300 ft | 350 ft | 400 ft | ||
|
|
| (45 m) | (60 m) | (70 m) | (90 m) | (105 m) | (120 m) | |||
|
|
|
|
| |||||||
Weld Output | Welding | 10 – 60% | 60 – 100% |
|
| 10 – 100% Duty Cycle |
| ||||
Duty | Duty |
|
|
| |||||||
Terminals | Amperes |
|
|
| |||||||
Cycle | Cycle |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| |||
SMAW/GTAW | 100 | 4 | 4 | 4 | 3 | 2 | 1 | 1/0 | 1/0 | ||
|
|
|
|
|
|
|
|
| |||
AC/CC (+) | AC/CC | 150 | 3 | 3 | 2 | 1 | 1/0 | 2/0 | 3/0 | 3/0 | |
|
| ||||||||||
|
| 200 | 3 | 2 | 1 | 1/0 | 2/0 | 3/0 | 4/0 | 4/0 | |
|
| 250 | 2 | 1 | 1/0 | 2/0 | 3/0 | 4/0 | |||
|
| 300 | 1 | 1/0 | 2/0 | 3/0 | 4/0 | ||||
|
| 350 | 1/0 | 2/0 | 3/0 | 4/0 | |||||
CV (+) | CV | 400 | 1/0 | 2/0 | 3/0 | 4/0 | |||||
FCAW/GMAW | |||||||||||
|
|
|
|
|
|
|
|
| |||
| Ref. | 500 | 2/0 | 3/0 | 4/0 | ||||||
Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. |
2-7. Remote 14 Receptacle
A | J | |
B | K | I |
|
| |
C | L N | H |
D | M | G |
| E | F |
Ref.
Socket* | Socket Information |
A24 volts ac. Protected by circuit breaker CB2.
BContact closure to A completes 24 volts ac contactor control circuit.
G | Circuit common for 24 and 115 volts ac circuits. |
|
|
I | 115 volts ac. Protected by circuit breaker CB1. |
JContact closure to I completes 115 volts ac contactor control circuit.
CCommand reference; 0 to +10 volts dc output to remote control.
DRemote control circuit common.
E0 to +10 volts dc input command signal from remote control.
K | Chassis common. |
*The remaining sockets are not used.