Jet Tools JDP-20VS manual Raising the Rack

Page 9

5.Tighten the two head locking bolts (A, Fig. 2). This will hold the head in place until the lock collar can be moved into position. The 2" x 4" can now be safely removed.

6.After the head is set at the desired height,

loosen two set screws (8, Fig. 2) on the lock collar.

7.Slide the lock collar up the column until it is flush with the head.

8.Firmly tighten two set screw (8, Fig. 2).

B

C

Raising the Rack

Some drilling operations will require the table to be moved closer to the spindle than the rack will allow as set by the factory. To raise the rack:

1.Tighten the table lock handle (A, Fig. 3).

2.Loosen two set screws (A, Fig. 4) on the column bearing collar (8, Fig. 4). Caution: Do not loosen two set screws (C, Fig. 4) with lock nuts.

3.Raise the rack (8, Fig. 3) to the desired level by turning the table raising handle (C, Fig. 3).

4.Tighten the two set screws (A, Fig. 4) to keep the rack in position. Now the table can be raised to the desired position.

Fig. 2

A

c

B

Fig. 3

7

Image 9
Contents LET Important Information It Warning Always Disconnectthemachinefromthepowersourcebeforeservicing Electrical Instructions 115Volt230Volt FigBJDP-20VS-3 SpecificationsInstallation Unpacking and Clean-UpRaising the Head Failure to coRaising the Rack Adjusting the Depth Stop for Drilling Control Panel JDP-20VS-1Changing Spindle Speeds Installing Drill Chuck Arbors or Taper Drill Bits Adjusting the Depth Stop for Tapping JDP-20VS-3 onlySpindle Preparation Removing Taper Drills or Chuck ArborsDrill Speed Chart Lubrication Location Type FrequencyVariable Drive Lubrication Location Type Frequency JDP-20VS-1/3 Head Assembly Qty JDP-20VS-1/3 Head Assembly Index Part SizeJDP-20VS-1/3 Head Assembly 15~1 JDP-20VS-1/3 Variable Speed AssemblyBelt Page JDP-20VS-1/3 Column, Table, and Base Assembly JDP-20VS-1/3 Depth Stop and Control Box Assembly 70-1611B Scale 70-1612B StrokeStop Bracket JDP-20VS Depth Stop and Control Box AssemblyIll Electrical Panel Components JDP-20VS-3 only 104 ReturnSwitchAC24V Page Page