MITER GAUGE OPERATION

AND ADJUSTMENTS

For cross-cutting (blade set 90 degrees to the table), the miter gauge can be used in either table slot. For bevel cross-cutting (with the blade tilted), use the miter gauge in the right table slot only so that the blade will be tilted away from the miter gauge and your hands.

To operate the miter gauge, loosen the lock knob (E) Fig. 34, and rotate the miter gauge to the desired angle.

E

Fig. 34

ADJUSTING BLADE PARALLEL TO MITER GAUGE SLOTS

The blade was adjusted parallel to the miter gauge slots at the factory. In order to ensure accurate cuts and help prevent kickback, check this adjustment.

To adjust:

DISCONNECT MACHINE FROM POWER SOURCE.

1.Raise the blade to its highest position and adjust the blade so that it is 90 degrees to the table.

2.Select a tooth on the saw blade that is set to the left. Mark this tooth with a pencil or marker.

3.Use a combination square (A) Fig. 35 against the miter gauge slot and adjust the blade (B) of the square until it touches the marked tooth.

4.Rotate the blade and check the same marked blade tooth at the rear of the saw table (Fig. 36).

B

A

Fig. 35

5.If the front and back measurements (Figs. 35 and 36) are not identical, you can adjust the blade. Start by loosening the nuts below the four screws (C) Fig. 37 on the table. Then loosen the screws (C). Carefully move the saw blade until the blade is parallel to the miter gauge slot. When done, tighten four nuts under the table and the four screws (C) Fig. 37 securely.

NOTE: If sufficient adjustment cannot be achieved by loosening the screws (C) Fig. 37, loosen the screw (D) Fig. 37 necessary to make the adjustment.

Fig. 36

C

D

Fig. 37

18

Image 18
Contents Motorized Bench Saw Table of Contents Important Safety InstructionsSafety Guidelines Definitions California PropositionStay ALERT, Watch What YOU are DOING, General Safety RulesImportant Safety Instructions USE of this Tool can GenerateAdditional Specific Safety Rules Failure to Follow These Rules MAY Result in Serious InjuryPower Connections Motor SpecificationsGrounding Instructions Carton Contents Functional DescriptionParts Assembly Tools Required AssemblyUnpacking and Cleaning Elevating and Supporting Surfaces for a SAW with no StandAssembling Stand for Model TS200LS SAW to Stand TS200LS onlyAttaching Blade Height Adjusting Handwheel Attaching Blade Guard and Splitter AssemblyOn the screw L Fig Miter Gauge Attaching Miter Gauge HolderAssembling RIP Fence Illustrates the miter gauge D inserted into the holderOperation Locking Switch in the OFF PositionBlade Height Adjustment Starting and Stopping SAWBlade Tilt Adjustment 45 Degree Positive Stop AdjustmentsTo Adjust Positive Stop AT 45 Degrees RIP Fence Operation Adjustments Table Insert AdjustmentMiter Gauge Operation Adjustments Adjusting Blade Parallel to Miter Gauge SlotsChanging the Blade CROSS-CUTTINGNever USE the Fence AS a CUT-OFF Gage When CROSS-CUTTING RippingConstructing a Push Stick Using Auxiliary Wood Facing on RIP FenceAccessory Dado Cutterhead Guard Removed for CLARITY. Always USE the GuardPage Pushstick Constructing a Push StickTroubleshooting Power Tool InstituteConstructing a Featherboard Accessories MaintenanceService WarrantyPage Canadian PORTER-CABLE Delta Service Centers