Allied Air Enterprises 4AC16LT manual Subcooling Values, Approach Values for TXV Systems

Page 14

R410A Temperature/Pressure Chart

Subcooling Values

 

T e m p .

P re s s u re

 

 

(F

P s ig

 

 

 

 

3 2

1 0 0 . 8

 

 

 

 

3 3

1 0 2 . 9

 

 

 

 

3 4

1 0 5 . 0

 

 

 

 

3 5

1 0 7 . 1

 

 

 

 

3 6

1 0 9 . 2

 

 

 

 

 

 

3 7

1 1 1 . 4

 

 

 

 

3 8

1 1 3 . 6

 

 

 

 

3 9

1 1 5 . 8

 

 

 

 

4 0

1 1 8 . 0

 

 

 

 

 

 

4 1

1 2 0 . 3

 

 

 

 

4 2

1 2 2 . 6

 

 

 

 

4 3

1 2 5 . 0

 

 

 

 

4 4

1 2 7 . 3

 

 

 

 

 

 

4 5

1 2 9 . 7

 

 

 

 

4 6

1 3 2 . 2

 

 

 

 

4 7

1 3 4 . 6

 

 

 

 

4 8

1 3 7 . 1

 

 

 

 

 

 

4 9

1 3 9 . 6

 

 

 

 

5 0

1 4 2 . 2

 

 

 

 

5 1

1 4 4 . 8

 

 

 

 

5 2

1 4 7 . 4

 

 

 

 

5 3

1 5 0 . 1

 

 

 

 

5 4

1 5 2 . 8

 

 

 

 

5 5

1 5 5 . 5

 

 

 

 

5 6

1 5 8 . 2

 

 

 

 

5 7

1 6 1 . 0

 

 

 

 

5 8

1 6 3 . 9

 

 

 

 

5 9

1 6 6 . 7

 

 

 

 

 

 

6 0

1 6 9 . 6

 

 

 

 

6 1

1 7 2 . 6

 

 

 

 

6 2

1 7 5 . 5

 

 

 

 

6 3

1 7 8 . 5

 

 

 

 

 

 

6 4

1 8 1 . 6

 

 

 

 

6 5

1 8 4 . 3

 

 

 

 

6 6

1 8 7 . 7

 

 

 

 

6 7

1 9 0 . 9

 

 

 

 

 

 

6 8

1 9 4 . 1

 

 

 

 

6 9

1 9 7 . 3

 

 

 

 

7 0

2 0 0 . 6

 

 

 

 

7 1

2 0 3 . 9

 

 

 

 

7 2

2 0 7 . 2

 

 

 

 

7 3

2 1 0 . 6

 

 

 

 

7 2

2 0 7 . 2

 

 

 

 

7 3

2 1 0 . 6

 

 

 

T e m p .

P re s s u re

(F

P s ig

 

 

7 4

2 1 4 . 0

 

 

7 5

2 1 7 . 4

 

 

7 6

2 2 0 . 9

 

 

7 7

2 2 4 . 4

 

 

7 8

2 2 8 . 0

 

 

 

 

7 9

2 3 1 . 6

 

 

8 0

2 3 5 . 3

 

 

8 1

2 3 9 . 0

 

 

8 2

2 4 2 . 7

 

 

 

 

8 3

2 4 6 . 5

 

 

8 4

2 5 0 . 3

 

 

8 5

2 5 4 . 1

 

 

8 6

2 5 8 . 0

 

 

 

 

8 7

2 6 2 . 0

 

 

8 8

2 6 6 . 0

 

 

8 9

2 7 0 . 0

 

 

9 0

2 7 4 . 1

 

 

 

 

9 1

2 7 8 . 2

 

 

9 2

2 8 2 . 3

 

 

9 3

2 8 6 . 5

 

 

9 4

2 9 0 . 3

 

 

9 5

2 9 5 . 1

 

 

9 6

2 9 9 . 4

 

 

9 7

3 0 3 . 8

 

 

9 8

3 0 8 . 2

 

 

9 9

3 1 2 . 7

 

 

1 0 0

3 1 7 . 2

 

 

1 0 1

3 2 1 . 8

 

 

 

 

1 0 2

3 2 6 . 4

 

 

1 0 3

3 3 1 . 0

 

 

1 0 4

3 3 5 . 7

 

 

1 0 5

3 4 0 . 5

 

 

 

 

1 0 6

3 4 5 . 3

 

 

1 0 7

3 5 0 . 1

 

 

1 0 8

3 5 5 . 0

 

 

1 0 9

3 6 0 . 0

 

 

 

 

1 1 0

3 6 5 . 0

 

 

1 1 1

3 7 0 . 0

 

 

1 1 2

3 7 5 . 1

 

 

1 1 3

3 8 0 . 2

 

 

1 1 4

3 8 5 . 4

 

 

1 1 5

3 9 0 . 7

 

 

1 1 4

3 8 5 . 4

 

 

1 1 5

3 9 0 . 7

 

 

T e m p .

P re s s u re

(F

P s ig

 

 

1 1 6

3 9 6 . 0

 

 

1 1 7

4 0 1 . 3

 

 

1 1 8

4 0 6 . 7

 

 

1 1 9

4 1 2 . 2

 

 

1 2 0

4 1 7 . 7

 

 

 

 

1 2 1

4 2 3 . 2

 

 

1 2 2

4 2 8 . 8

 

 

1 2 3

4 3 4 . 5

 

 

1 2 4

4 4 0 . 2

 

 

 

 

1 2 5

4 4 5 . 9

 

 

1 2 6

4 5 1 . 8

 

 

1 2 7

4 5 7 . 6

 

 

1 2 8

4 6 3 . 5

 

 

 

 

1 2 9

4 6 9 . 5

 

 

1 3 0

4 7 5 . 6

 

 

1 3 1

4 8 1 . 6

 

 

1 3 2

4 8 7 . 8

 

 

 

 

1 3 3

4 9 4 . 0

 

 

1 3 4

5 0 0 . 2

 

 

1 3 5

5 0 6 . 5

 

 

1 3 6

5 1 2 . 9

 

 

1 3 7

5 1 9 . 3

 

 

1 3 8

5 2 5 . 8

 

 

1 3 9

5 3 2 . 4

 

 

1 4 0

5 3 9 . 0

 

 

1 4 1

5 4 5 . 6

 

 

1 4 2

5 5 2 . 3

 

 

1 4 3

5 5 9 . 1

 

 

 

 

1 4 4

5 6 5 . 9

 

 

1 4 5

5 7 2 . 8

 

 

1 4 6

5 7 9 . 8

 

 

1 4 7

5 8 6 . 8

 

 

 

 

1 4 8

5 9 3 . 8

 

 

1 4 9

6 0 1 . 0

 

 

1 5 0

6 0 8 . 1

 

 

1 5 1

6 1 5 . 4

 

 

 

 

1 5 2

6 2 2 . 7

 

 

1 5 3

6 3 0 . 1

 

 

1 5 4

6 3 7 . 5

 

 

1 5 5

 

6 4 5 . 0

 

 

 

 

 

 

Table 6

° Liquid Line Temperature °F

_

° Outdoor Ambient Temperature °F

=° Approach Temperature °F

6.Compare the approach value with those shown in Table

7.If the values do not agree with those provided in Table 7, add refrigerant to lower the approach temperature or recover refrigerant from the system to increase the approach temperature.

Check Charge Using Normal Operating Pressures Use Table 8 to perform maintenance checks. Table 8 is not a procedure for charging the system. Minor variations in these pressures may be due to differences in installations. Significant deviations could mean that the system is not properly charged or that a problem exists with some component in the system.

Approach Values for TXV Systems

Approach value is the liquid line temperature minus the outdoor ambient temperature (± 1°F).

Note: For best results, use the same digital thermometer to check both outdoor ambient and liquid temperatures.

Table 7

Table 5

506467-01

Issue 1008

Page 14

Image 14
Contents 4AC16LT Series Lennox International Inc. CompanyTorque Table InstallationInstallation Clearances Slab MountingThermostat Designations Electrical WiringSlab Mounting Refrigerant PipingLine Set Isolation Installing Refrigerant LinePlacement Refrigerant Metering Device on Outside Unit Placement InstallationRefrigerant Line Sets Installing Horizontal Runs Refrigerant Line Sets Transition from Vertical to Horizontal Flushing Connections Flushing Existing Line Set and Indoor CoilRefrigerant Metering Device TXV DataTo Close Liquid or Suction Line Service Valve Liquid and Suction Line Service ValvesTo Access the Schrader Port Suction Line Ball Type Service ValveUsing an Electronic Leak Detector Ball Type Service Valve Valve OpenLeak Testing EvacuationPage Refrigerant Charging Refrigerant Charge AdjustmentSTART-UP Charge Using Weigh-In Method Blocking Outdoor CoilApproach Values for TXV Systems R410A Temperature/Pressure ChartSubcooling Values Issue Thermostat Demand Wiring Interpreting the Diagnostic LEDs24VAC Power Wiring OperationFlash Codes LEDFault Description Troubleshooting Information Status Miswired Module Troubleshooting Sensing holesIndoor Unit MaintenanceIndoor Coil Start-Up and Performance Checklist Wiring Diagram P/N

4AC16LT specifications

The Allied Air Enterprises 4AC16LT is a highly efficient air conditioning unit designed to provide optimal cooling solutions for residential and light commercial applications. This model exemplifies the balance of innovative technology and user-friendly features, making it a popular choice for homeowners and contractors alike.

One of the standout characteristics of the 4AC16LT is its ENERGY STAR certification, which signifies its energy efficiency and eco-friendly operation. The unit is engineered to reduce energy consumption while delivering reliable performance, ultimately helping to lower electricity bills for consumers.

The 4AC16LT features a scroll compressor, a technology known for its durability and efficiency. This compressor design not only improves the overall cooling efficiency but also minimizes operational noise, providing a quiet and comfortable indoor environment. The unit's sound levels are notably reduced, making it ideal for residential settings where noise can be a significant concern.

In addition to its efficient compressor, the unit boasts a range of advanced technologies. The integrated smart diagnostic features allow technicians to quickly identify and troubleshoot issues, streamlining maintenance and reducing downtime. This is particularly beneficial for contractors, as it enhances service response times and customer satisfaction.

The 4AC16LT is also equipped with a durable cabinet design, which is resistant to rust and corrosion, ensuring longevity and reliability in various environmental conditions. The pre-painted steel casing not only enhances the unit’s durability but also adds an aesthetic appeal that blends well with most home exteriors.

Further enhancing its appeal, the unit utilizes environmentally friendly refrigerants that comply with current regulations. This commitment to sustainability demonstrates Allied Air Enterprises’ focus on innovation while caring for the environment.

Moreover, the model is designed with ease of installation in mind. The compact size and lightweight construction of the 4AC16LT facilitate straightforward installation, saving time and labor costs for technicians.

In summary, the Allied Air Enterprises 4AC16LT air conditioning unit is a top-tier choice that incorporates energy efficiency, advanced technology, and a user-friendly design. Its combination of quiet operation, robust features, and commitment to sustainability makes it an excellent investment for anyone seeking reliable indoor comfort.