5.Disconnect yellow flame sensor wire from the ignition con- trol.
6.Remove the screw securing the brown wire from the burner assembly and the green wire from the
7.Disconnect the gray and brown wires from the gas valve, and remove blue wires from the rollout switch.
→ | Table |
| |
|
|
|
|
| ITEM |
| QUANTITY |
| LP Gas Orifice No. 41* |
| 3 |
| LP Gas Orifice No. 42* |
| 3 |
| LP Gas Orifice No. 46* |
| 3 |
| Warning Label |
| 1 |
| Conversion Label |
| 1 |
| Responsibility Label |
| 1 |
*Refer to Table 2 to determine the correct orifice to use. LP- Liquid Propane
→8. Remove the screw attaching the gas manifold to the basepan, and slide out the entire burner rack assembly from unit. Save screw.
→9. Inspect the inlet of the heat exchanger tubes for presence of
10.Using a 5/16 in. nut driver, remove the four screws securing the manifold/gas valve assembly to the burner assembly. Save these screws.
11.Remove the natural gas orifices from the manifold using a 9/16 in. wrench and install the correct LP gas orifices in the manifold (See Table 2 to select correct orifice size based on input. See Fig. 2 for orifice installation).
12.Replace the manifold/gas valve assembly into the burner assembly using the four screws saved from Step 10.
13.Reconnect the blue wires to the rollout switch and reinstall rollout switch.
14.Reconnect the gray wire removed in Step 7 to terminal 1 (M1) of the gas valve. Reconnect the brown wire to terminal 2 (C2) on the main gas valve.
15.Reconnect orange sparker cable and the yellow flame sensor wires at the ignition control.
16.Slide burner rack assembly into basepan. Align burner rack with screws on sheet metal partition and slide assembly back tight to the partition. Replace the screw attaching the burner rack to the basepan, removed in Step 8.
17.Reconnect the brown wire from the burner assembly and the green wire from the
18.Remove the 1/8” pipe plug on the gas manifold and connect a pressure manometer.
19.Reconnect electrical power and gas supply to the unit.
20.Fire unit and verify proper ignition. Verify that the pressure manometer reads
21.Turn off unit, remove pressure manometer and replace the
22.Attach warning label (P/N 48GS500615) to visible side of gas valve.
23.Attach conversion label (P/N 48GS500614) above unit rating plate on exterior of unit.
24.Attach completed conversion responsibility label (see Fig. 3, P/N 48SS500283) inside service access panel.
25.IMPORTANT: Restart unit and leak check all gas connec- tions including the main service connection, gas valve, gas spuds, and manifold pipe plug.
26.After all leaks are eliminated, replace service panel.
2