Carrier 1625, 2025 Mount the Cabinet, Electrical Shock Hazard, Unit Damage Hazard

Page 4

Step 8Mount the Cabinet

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch.

GAPA

 

 

 

!

CAUTION

 

 

UNIT DAMAGE HAZARD

Failure to follow this caution may result in equipment damage.

Cabinets will support a maximum weight of 400 lbs when installed beneath a vertical furnace or air-handling unit. When setting furnace on cabinet, do not drop it into place. Position the furnace correctly on the cabinet to prevent a corner from slipping down and damaging the cabinet or its components.

a.Turn off power to the heating and cooling system.

b.Remove the existing furnace filter and discard. Excessive system static may result if the Infinityt Air Purifier is used with other filtration devices.

c.Remove the air purifier cartridge and enhancement module from the Infinityt Air Purifier cabinet.

d.Position the cabinet between the furnace and return air duct (see Fig. 3 and 4). A transition duct may be required.

e.Furnace adapters have been included for installer convenience. They are designed for top or bottom mount installations (see Fig. 5).

f.Return air duct adapters have been included for installer convenience. They should be used to connect the upstream side of the air purifier cabinet to the return air duct (see Fig. 6).

g.Install foam tape between the furnace and the air purifier cabinet.

h.Mounting holes are provided for ductwork and furnace attachment.

!CAUTION

UNIT DAMAGE HAZARD

Failure to follow this caution may result in unit damage.

Mounting holes are provided for duct work and furnace attachment. The screws on the down-stream side of the cabinet should be installed so that the screw heads are inside air purifier cabinet to prevent damage to the air purifier cartridge.

i.Seal seams with tape or caulking after the Infinityt Air Purifier cabinet has been secured.

Return Duct

Adapters (x4)

Return

Duct

 

Furnace

Adapters (x2)

Furnace

Adapters (x2)

Return Duct

Adapters (x4)

Return

Duct

 

Top Mount

Bottom Mount

Side Mount

A06029

Fig. 4 - Mounting Infinityt Air Purifier Cabinet

4

Image 4
Contents Safety Considerations Table of ContentsIntroduction HOW IT WorksApplication Considerations Installation Check Infinityt Air Purifier ComponentsCUT Hazard Identify Mounting LocationElectrical Shock Hazard Mount the CabinetUnit Damage Hazard Equipment Damage Hazard Unit Component Damage HazardMaintenance START-UP and OperationChecking Air Purifier Operation Infinity ControlTroubleshooting Safety HazardSpecifications and Dimensions DimensionsCarrier Corporation No GAPA---2SI

2025, 1625 specifications

The Carrier 1625 and 2025 are cutting-edge HVAC units designed to deliver superior efficiency and performance for residential and commercial applications. These advanced models have garnered attention for their innovative features, energy-saving technologies, and commitment to sustainability, making them ideal choices for modern indoor climate control.

One of the key highlights of the Carrier 1625 and 2025 is their energy efficiency. Both units are equipped with advanced variable-speed compressor technology, allowing them to adjust their output based on current cooling needs. This not only increases comfort levels but also significantly reduces energy consumption, translating to lower utility bills for users. With seasonal energy efficiency ratios (SEER) that exceed 16, both models meet rigorous energy efficiency standards set by regulatory bodies.

In addition to efficiency, these units prioritize quiet operation. The Carrier 1625 and 2025 feature specially designed sound-dampening cabinets and advanced fan technology, ensuring that they operate quietly without compromising on performance. This is particularly beneficial for residential settings, where noise can be a significant concern.

The Carrier 1625 and 2025 come equipped with cutting-edge smart technologies that enhance user experience. Wi-Fi connectivity allows homeowners and building managers to monitor and control their HVAC systems remotely via smartphone applications. This capability enables users to adjust settings, schedule maintenance, and receive alerts, providing unmatched convenience and peace of mind.

Another noteworthy feature is the use of eco-friendly refrigerants, which help reduce environmental impact without sacrificing performance. Carrier is committed to sustainability, and the 1625 and 2025 models reflect this commitment through their energy-efficient design and reduced greenhouse gas emissions.

Furthermore, both units are designed for easy installation and maintenance. Their modular components allow technicians to access parts with ease, facilitating quicker repairs and servicing, thus minimizing downtime.

In summary, the Carrier 1625 and 2025 represent the forefront of HVAC technology. With their energy-efficient operation, quiet performance, smart technology integration, and eco-friendly refrigerants, they are perfect for those seeking comfort and sustainability in their climate control solutions. Whether for residential or commercial use, these models provide an ideal balance of performance, innovation, and environmental responsibility, making them standout choices in the HVAC market.