Carrier 2025, 1625 operating instructions Troubleshooting, Safety Hazard

Page 7

Step 2Turn the Infinityt Air Purifier switch to the off position.

Step 3Remove the Infinityt Air Purifier door.

Step 4Slide out the old air purifier cartridge and discard. Step 5Install the new air purifier cartridge.

NOTE: Make sure that the arrows on the air purifier cartridge point toward the furnace. This should be in the same direction as airflow.

Step 6Replace the Infinityt Air Purifier door.

Step 7Turn the Infinityt Air Purifier switch to the on position.

Step 8Turn on the heating and cooling system.

Door Switch Magnet

A06053

Fig. 9 - Door Switch Magnet

TROUBLESHOOTING

!CAUTION

SAFETY HAZARD

Failure to follow this caution may result in personal injury or equipment damage.

The following instructions are for use by qualified personnel only.

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

The following procedures will expose electrical components. Disconnect power between checks and proceed carefully.

The Infinityt Air Purifier is equipped with a power indicator light located on the door (see Fig. 8). This power indicator light will illuminate when the Infinityt Air Purifier door is installed, the power switch is in the on position, AND the furnace blower is running. If the power indicator light is not illuminated, follow the troubleshooting steps below.

Step 1Check that the Infinityt Air Purifier door is installed.

NOTE: A magnet in the door (see Fig. 9) is used to activate a safety switch in the power supply when the door is installed. The power supply will not energize the air purifier unless the safety switch is activated.

Step 2Check that the Infinityt Air Purifier power switch is in the on (closed) position.

Step 3Confirm that the furnace blower is operating.

NOTE: Power will not be supplied to the Infinityt Air Purifier from the furnace controls EAC terminals unless the blower is running.

Step 4Confirm that power provided from the furnace control EAC terminals is being conducted through the wiring to the Infinityt Air Purifier power supply.

Step 5If all of the above steps are completed and the power indicator light is still not illuminating, replace the power supply on the enhancement module. Note that there are no serviceable parts within the power supply.

GAPA

7

Image 7
Contents HOW IT Works Safety ConsiderationsTable of Contents IntroductionApplication Considerations Identify Mounting Location InstallationCheck Infinityt Air Purifier Components CUT HazardElectrical Shock Hazard Mount the CabinetUnit Damage Hazard Unit Component Damage Hazard Equipment Damage HazardInfinity Control MaintenanceSTART-UP and Operation Checking Air Purifier OperationSafety Hazard TroubleshootingDimensions Specifications and DimensionsCarrier Corporation No GAPA---2SI

2025, 1625 specifications

The Carrier 1625 and 2025 are cutting-edge HVAC units designed to deliver superior efficiency and performance for residential and commercial applications. These advanced models have garnered attention for their innovative features, energy-saving technologies, and commitment to sustainability, making them ideal choices for modern indoor climate control.

One of the key highlights of the Carrier 1625 and 2025 is their energy efficiency. Both units are equipped with advanced variable-speed compressor technology, allowing them to adjust their output based on current cooling needs. This not only increases comfort levels but also significantly reduces energy consumption, translating to lower utility bills for users. With seasonal energy efficiency ratios (SEER) that exceed 16, both models meet rigorous energy efficiency standards set by regulatory bodies.

In addition to efficiency, these units prioritize quiet operation. The Carrier 1625 and 2025 feature specially designed sound-dampening cabinets and advanced fan technology, ensuring that they operate quietly without compromising on performance. This is particularly beneficial for residential settings, where noise can be a significant concern.

The Carrier 1625 and 2025 come equipped with cutting-edge smart technologies that enhance user experience. Wi-Fi connectivity allows homeowners and building managers to monitor and control their HVAC systems remotely via smartphone applications. This capability enables users to adjust settings, schedule maintenance, and receive alerts, providing unmatched convenience and peace of mind.

Another noteworthy feature is the use of eco-friendly refrigerants, which help reduce environmental impact without sacrificing performance. Carrier is committed to sustainability, and the 1625 and 2025 models reflect this commitment through their energy-efficient design and reduced greenhouse gas emissions.

Furthermore, both units are designed for easy installation and maintenance. Their modular components allow technicians to access parts with ease, facilitating quicker repairs and servicing, thus minimizing downtime.

In summary, the Carrier 1625 and 2025 represent the forefront of HVAC technology. With their energy-efficient operation, quiet performance, smart technology integration, and eco-friendly refrigerants, they are perfect for those seeking comfort and sustainability in their climate control solutions. Whether for residential or commercial use, these models provide an ideal balance of performance, innovation, and environmental responsibility, making them standout choices in the HVAC market.