Carrier ASPAS1CCA007 owner manual Service Schedule, Be performed by the nearest Carrier Dealer

Page 19

Section 4 — Service Schedule

Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators

 

SERVICE

4.1SERVICE SCHEDULE

ATTENTION: It is recommended that all service work

be performed by the nearest Carrier Dealer.

 

SYSTEM/COMPONENT

 

 

PROCEDURE

 

FREQUENCY

 

 

X = Action

Inspect

 

Change

 

Clean

W = Weekly

 

 

R = Replace as Necessary

 

 

 

 

 

M = Monthly

 

 

* = Notify Dealer

 

 

 

 

 

Y = Yearly

 

 

if Repair is Needed.

 

 

 

 

 

 

 

 

FUEL

 

 

 

 

 

 

 

 

Fuel lines and connections*

X

 

 

 

 

M

 

 

LUBRICATION

 

 

 

 

 

 

 

 

Oil level

X

 

 

 

 

M

 

 

Oil

 

 

X

 

 

AFTER BREAK-IN,

 

 

 

 

 

 

 

 

AND Y

 

 

Oil filter

 

 

X

 

 

AFTER BREAK-IN,

 

 

 

 

 

 

 

 

AND Y

 

 

COOLING

 

 

 

 

 

 

 

 

Enclosure louvers

X

 

 

 

X

W

 

 

BATTERY

 

 

 

 

 

 

 

 

Remove corrosion,

X

 

 

 

X

M

 

 

ensure dryness

 

 

 

 

 

 

 

 

Clean and tighten

X

 

 

 

X

M

 

 

battery terminals

 

 

 

 

 

 

 

 

Check charge state

X

 

R

 

 

EVERY 6 M

 

 

Electrolyte level

X

 

R

 

 

EVERY 6 M

 

 

(unsealed batteries only)*

 

 

 

 

 

 

 

 

ENGINE AND MOUNTING

 

 

 

 

 

 

 

 

Air cleaner

X

 

R

 

 

Y

 

 

Spark plug(s)

X

 

R

 

 

Y

 

 

GENERAL CONDITION

 

 

 

 

 

 

 

 

Vibration, Noise, Leakage,

X

 

 

 

 

M

 

 

Temperature*

 

 

 

 

 

 

 

 

COMPLETE TUNE-UP*

 

TO BE COMPLETED BY A

 

Y

 

 

 

 

CARRIER DEALER

 

 

 

 

 

 

 

 

 

 

 

 

Carrier 17

Image 19
Contents US Listed Introduction ‹ Contents‹ Operation and Maintenance ‹ HOW to Obtain ServiceWarranty MaintenanceService TroubleshootingGeneral Hazards ‹ Standards Index Electrical HazardsFire Hazards Explosion HazardsProtection Systems UNPACKING/INSPECTIONBreaker for Bedrooms Gfci Generator‹ 1.5.1 Generator SpecificationsSystem SET LED Fuel Requirements RecommendationsLifting the Generator Transfer SwitchFuel Consumption LocationBattery Battery Installation‹ 2.2.3 Manual Position BREAK-IN Procedure‹ 2.2.1 Auto Position ‹ 2.2.2 OFF Position‹ 2.3.2 120 VAC Gfci Outlet ‹ 2.3.1 12 VDC Accessory OutletAutomatic Transfer Operation Sequence of Automatic Operation‹ 2.5.2 Transfer Back to Utility Power Source Setting the Exercise TimerManual Transfer Operation ‹ 2.7.2 High Temperature Switch ‹ 2.7.1 LOW OIL Pressure SwitchFuses ‹ 3.3.1 Engine OIL Recommendations ‹ 3.3.2 OIL Change ProcedureChecking the Engine OIL Level Changing the Engine OIL‹ 3.5.1 7 KW, 12 KW and 15 KW Generators Changing the Engine AIR CleanerChanging the OIL Filter Spark PlugsCooling System Battery MaintenanceCorrosion Protection OUT of Service Procedure‹ 3.11.1 Removal from Service ‹ 3.11.2 Return to ServiceBe performed by the nearest Carrier Dealer Service ScheduleProblem Cause Correction Troubleshooting GuideWarranty Schedule MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyCatalog NO. OMASPAS07-2

ASPAS1CCA007 specifications

The Carrier ASPAS1CCA007 is a leading-edge air conditioning unit designed for residential and commercial applications. Known for its exceptional performance and energy efficiency, this model showcases a blend of advanced technologies and features that cater to modern cooling needs.

One of the standout characteristics of the ASPAS1CCA007 is its impressive SEER (Seasonal Energy Efficiency Ratio) rating. This high rating signifies that the unit provides superior cooling while minimizing energy consumption, making it an environmentally friendly choice that can reduce electricity bills. The energy efficiency is further enhanced by the use of advanced inverter technology, allowing the compressor to adjust its speed according to the cooling demands. This results in smoother operation, lower noise levels, and extended equipment life.

The ASPAS1CCA007 is designed for versatility, featuring a sleek and compact design that allows for easy installation in various spaces. Its multi-mode operation allows the unit to function in cooling, heating, and dehumidifying modes, providing year-round comfort. The integrated air filtration system effectively captures dust, pollen, and other allergens, ensuring cleaner indoor air quality.

Control and convenience are also key aspects of the ASPAS1CCA007. The unit is equipped with a user-friendly remote control and is compatible with smart home systems, enabling users to manage their indoor climate effectively from anywhere. The programmable timer and thermostat settings allow for personalized comfort and energy savings by optimizing the unit's operation according to the user's schedule.

Durability is another important feature, as the ASPAS1CCA007 is constructed from high-quality materials designed to withstand harsh weather conditions. The high-efficiency rotary compressor and corrosion-resistant components enhance reliability and longevity. Additionally, the unit operates quietly, making it suitable for installation in bedrooms, offices, and other noise-sensitive environments.

In summary, the Carrier ASPAS1CCA007 stands out in the market for its energy efficiency, advanced technologies, versatile operation modes, user-friendly controls, and robust design. It represents a smart investment for those seeking a reliable air conditioning solution that combines comfort, efficiency, and durability in a single package. Whether for home or office use, this unit exemplifies Carrier's commitment to quality and innovation in climate control.