Carrier ASPAS1CCA007 owner manual Unpacking/Inspection, Protection Systems, Breaker for Bedrooms

Page 6

Section 1 — General Information

Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators

DANGER

Only qualified electricians or contractors should

!attempt such installations, which must comply strictly with applicable codes, standards and regulations.

1.1UNPACKING/INSPECTION

After unpacking, carefully inspect the contents for damage.

This standby generator set has been factory supplied with a weather protective enclosure that is intended for outdoor installation only.

This UL listed standby generator set is packaged with an automatic transfer switch with built in load center. The combination transfer switch and load center is pre-wired with a two foot and 30 foot conduit. Circuit breakers for emergency circuit connections are included.

This UL listed, 2-pole switch is rated at 100 AC amperes at 250 volts maximum. This transfer switch is for indoor use only.

If this generator is used to power electrical load circuits normally powered by a utility power source, it is required by code to install a transfer switch. The transfer switch must effectively isolate the electrical system from the utility distribution system when the generator is operating (NEC 700, 701 & 702). Failure to isolate an electrical system by such means will result in damage to the generator and also may result in injury or death to utility power workers due to backfeed of electrical energy.

If any loss or damage is noted at time of delivery, have the person(s) making the delivery note all damage on the freight bill or affix their signature under the consignor's memo of loss or damage.

If a loss or damage is noted after delivery, separate the damaged materials and contact the Carrier for claim procedures.

“Concealed damage” is understood to mean damage to the contents of a package that is not in evidence at the time of delivery, but is discovered later.

1.2PROTECTION SYSTEMS

Unlike an automobile engine, the generator may have to run for long periods of time with no operator present to monitor engine conditions. For that reason, the engine is equipped with the following systems that protect it against potentially damaging conditions:

1.

Low Oil Pressure Sensor

3.

Overcrank

2.

High Temperature Sensor

4.

Overspeed

There are LED readouts on the control panel to notify personnel that one of these faults has occurred. There is also a “System Set” LED that is lit when all of the conditions describe in Section 1.3 are true.

1.3NEC REQUIREMENT FOR ARC FAULT CIRCUIT INTERRUPTION

BREAKER FOR BEDROOMS

In 2001, the National Electric Code (NEC) introduced a requirement for new construction. This new requirement indicates the need for Arc Fault Circuit Interrupters to be used to protect the complete branch circuit that feeds a dwelling bedroom. The actual NEC requirement is indicated below.

‹1.3.1 SECTION 210.12 ARC FAULT CIRCUIT INTERRUPTER PROTECTION

1.Definition: An arc fault circuit interrupter is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by functioning to de-energize the circuit when an arc fault is detected.

2.Dwelling Unit Bedrooms: All branch circuits that supply 125 volt, single-phase, 15 and 20 ampere outlets installed in dwelling unit bedrooms shall be protected by an arc fault circuit interrupter listed to provide protection of the entire branch circuit.

Section 210.12 requires that AFCI protection be provided on branch circuits that supply outlets (receptacle, lighting, etc.) in dwelling bedrooms. The requirement is limited to 15 and 20 ampere, 125 volt circuits. There is no prohibition against providing AFCI protection on other circuits or in locations other than bedrooms. Because circuits are often shared between a bedroom and other areas such as closets and hallways, providing AFCI protection on the complete circuit would comply with 210.12.

If during the installation of the Carrier Home Standby system the decision is made to provide back up power to a bedroom branch circuit, then the circuit breaker in the Carrier Transfer Switch should be replaced with an Arc Fault Circuit Interrupter.

It is most important that breakers only be switched like for like. For instance, if replacing a 15A breaker, it MUST be replaced with a 15A AFCI breaker. Likewise, a 20A breaker MUST be replaced with a 20A AFCI.

These AFCI breakers are available at the nearest electrical wholesaler or hardware store.

Siemens Item #

Description

Q115AF

15A Single Pole AFCI

Q120AF

20A Single Pole AFCI

4 Carrier

Image 6
Contents US Listed ‹ HOW to Obtain Service ‹ Contents‹ Operation and Maintenance IntroductionTroubleshooting MaintenanceService WarrantyGeneral Hazards Explosion Hazards Electrical HazardsFire Hazards ‹ Standards IndexUNPACKING/INSPECTION Protection SystemsBreaker for Bedrooms Generator GfciFuel Requirements Recommendations SpecificationsSystem SET LED ‹ 1.5.1 GeneratorLocation Transfer SwitchFuel Consumption Lifting the GeneratorBattery Installation Battery‹ 2.2.2 OFF Position BREAK-IN Procedure‹ 2.2.1 Auto Position ‹ 2.2.3 Manual PositionSequence of Automatic Operation ‹ 2.3.1 12 VDC Accessory OutletAutomatic Transfer Operation ‹ 2.3.2 120 VAC Gfci OutletSetting the Exercise Timer ‹ 2.5.2 Transfer Back to Utility Power SourceManual Transfer Operation ‹ 2.7.1 LOW OIL Pressure Switch ‹ 2.7.2 High Temperature SwitchFuses Changing the Engine OIL ‹ 3.3.2 OIL Change ProcedureChecking the Engine OIL Level ‹ 3.3.1 Engine OIL RecommendationsSpark Plugs Changing the Engine AIR CleanerChanging the OIL Filter ‹ 3.5.1 7 KW, 12 KW and 15 KW GeneratorsBattery Maintenance Cooling System‹ 3.11.2 Return to Service OUT of Service Procedure‹ 3.11.1 Removal from Service Corrosion ProtectionService Schedule Be performed by the nearest Carrier DealerTroubleshooting Guide Problem Cause CorrectionWarranty Schedule Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingCatalog NO. OMASPAS07-2

ASPAS1CCA007 specifications

The Carrier ASPAS1CCA007 is a leading-edge air conditioning unit designed for residential and commercial applications. Known for its exceptional performance and energy efficiency, this model showcases a blend of advanced technologies and features that cater to modern cooling needs.

One of the standout characteristics of the ASPAS1CCA007 is its impressive SEER (Seasonal Energy Efficiency Ratio) rating. This high rating signifies that the unit provides superior cooling while minimizing energy consumption, making it an environmentally friendly choice that can reduce electricity bills. The energy efficiency is further enhanced by the use of advanced inverter technology, allowing the compressor to adjust its speed according to the cooling demands. This results in smoother operation, lower noise levels, and extended equipment life.

The ASPAS1CCA007 is designed for versatility, featuring a sleek and compact design that allows for easy installation in various spaces. Its multi-mode operation allows the unit to function in cooling, heating, and dehumidifying modes, providing year-round comfort. The integrated air filtration system effectively captures dust, pollen, and other allergens, ensuring cleaner indoor air quality.

Control and convenience are also key aspects of the ASPAS1CCA007. The unit is equipped with a user-friendly remote control and is compatible with smart home systems, enabling users to manage their indoor climate effectively from anywhere. The programmable timer and thermostat settings allow for personalized comfort and energy savings by optimizing the unit's operation according to the user's schedule.

Durability is another important feature, as the ASPAS1CCA007 is constructed from high-quality materials designed to withstand harsh weather conditions. The high-efficiency rotary compressor and corrosion-resistant components enhance reliability and longevity. Additionally, the unit operates quietly, making it suitable for installation in bedrooms, offices, and other noise-sensitive environments.

In summary, the Carrier ASPAS1CCA007 stands out in the market for its energy efficiency, advanced technologies, versatile operation modes, user-friendly controls, and robust design. It represents a smart investment for those seeking a reliable air conditioning solution that combines comfort, efficiency, and durability in a single package. Whether for home or office use, this unit exemplifies Carrier's commitment to quality and innovation in climate control.