Windsor QQS34SP, QQS28 operating instructions Machine Operation

Page 7

STARTING MACHINE

NOTE: Perform pre-run machine check before operating machine.

FOR SAFETY: Before starting machine, make sure that all safety devices are in place and operating properly.

1.Turn the key switch clockwise to the “ON” position. Move the directional control lever in the desired direction.

FILLING THE SABER/STRIDE II

FOR SAFETY: Before leaving or servicing machine; stop on level surface, set parking brake, turn off ma- chine and remove key.

1.Set the parking brake, and turn “OFF” key switch.

2.Remove solution tank cover.

3.Fill the solution tank with clean water, leaving enough room for the required amount of cleaning solution. The solution tank capacity is 33 gallons (124.9 liters). The water must not be hotter than 140°F (60°C) to prevent damage to the tank.

4.Measure the chemical into the solution tank. Liquid chemicals should be added to the solution tank after filling with water. Dry chemicals should be thoroughly mixed before being added into solution tank. Commercially available, high alkaline floor cleaners are suitable for use in the SABER/STRIDE II solution system.

NOTE: Read the chemical manufactures recommended proportion instructions.

5.Fill the solution 5” from the bottom of the fill inlet.

6.Replace solution tank cover.

!WARNING

Flammable materials can cause an explosion or fire. Do not use flammable materials in the tanks

MACHINE OPERATION

SCRUBBING WITH THE SABER/STRIDE II

Plan the scrubbing pattern in advance. The longest track is around the perimeter of the area to be cleaned. For efficient operation, the runs should be the longest possible without turning, stopping, or raising and lowering scrub deck/ squeegee.

NOTE: In order to achieve the best possible results, the area which is to be cleaned should be swept before scrub- bing. Large debris, strings, wire must be removed to pre- vent being caught in brushes or squeegee.

BEGIN SCRUBBING

1.Turn key switch to “ON” and release the brake.

2.Travel to the start of the scrub pattern. Press the brush button number 1 on the console touch pad to start the vacuum, brush motors, and lower scrub deck and manually lower squeegee to the floor.

3.Press the scrub pressure button to the desired scrubbing pressure.

4.Finally adjust the solution flow using lever to the left of the control panel.

STOP SCRUBBING

1.Raise the scrub head, again using button number 1. Allow directions lever to return to neutral position after squeegee has passed beyond the position where the scrub deck was raised. Vacuum motor will cut off after an additional 14 second delay in order to clear the recovery system of solution.

2.Turn the key switch "OFF” and set the parking brake.

3.Pull back solution knob to full off position if scrubbing operation is complete.

SABER/STRIDE II 28/34 98570 5/1/98

7

Image 7
Contents Stride SaberOverview Using this ManualMachine Data LOG Your DealerTable of Contents Hazard Intensity Level SafetyMODELSABER/STRIDE II 28/34 Technical SpecificationsOperation Controls Machine Operation Double Scrub Emptying and Cleaning TanksFinished Floors MaintenanceScrub Brushes Uncoated FloorsTOO Much Scrub Deck Skirt and SqueegeeSqueegee Blades Correct Not EnoughTires and Wheels Adjusting SqueegeeTo Adjust Squeegee Pitch To Adjust Amount of Rear Squeegee DeflectionChecking Gravity Battery MaintenanceChecking Battery Specific Gravity BatteriesChanging Batteries To Charge the BatteriesBefore Starting Work Period End of Work Storing Service ScheduleBrush Head Options Squeegee BLADE/BRUSH Head Options Squeegee Blade OptionsALL Models Service Location DetailsService Location Parts List