Carrier manual Accessory Roof Curb 50XP024-060, Ordering Number

Page 10

50XP

ACCESSORY ROOF CURB - 50XP024-060

HVACunit base

Screw

Gasketing

(NO TE A)

inner flange*

*Gasketing

 

outer flange

 

 

Wood nailer*

Flashing field

 

supplied

Roofcurb*

 

Insulation(field

Roofing material

supplied)

 

field supplied

 

 

Duct work

Cant strip

field supplied

 

field supplied

 

 

Roof

*Provided with roofcurb

 

Roof Curb for Small Cabinet

Note A:When unit mounting screw is used, retainer bracket must also be used.

HVAC unit

 

base

 

 

Gask eting

Screw

inner flange*

 

(NOTE A)

 

*Gasketing

 

outer flange

 

 

Wood nailer*

Flashing field

 

supplied

Roofcurb*

 

Insulation(field

Roofing material

supplied)

 

field supplied

 

 

Duct work

Cant strip

field supplied

field supplied

 

 

Roof

*Provided with roofcurb

Roof Curb for Large Cabinet

Note A:When unit mounting screw is used, retainer bracket must also be used.

Supply opening (B x C)

BTyp.

D

44 5/16"

CTyp.

 

(1126 mm)

 

A

Short

Support

Insulated

deck pan

Long

Support

Return opening (B X C)

R/A

S/A

 

Gasket around

 

duct

Insulated

Gasket around

deck pan

outer edge

 

C00076

UNIT SIZE

ORDERING NUMBER

A

B

C

D

IN. (MM)

IN. (MM)

IN. (MM)

IN. (MM)

 

 

 

 

 

 

 

 

50XP024-036

CPRFCURB006A00

8 (203)

11 (279)

16--1/2 (419)

28--3/4 (730)

 

 

 

 

 

CPRFCURB007A00

14 (356)

11 (279)

16--1/2 (419)

28--3/4 (730)

 

 

 

 

 

 

 

50XP042-060

CPRFCURB008A00

8 (203)

16--3/16 (411)

17--3/8 (441)

40--1/4 (1022)

 

 

 

 

 

CPRFCURB009A00

14 (356)

16--3/16 (411)

17--3/8 (441)

40--1/4 (1022)

 

NOTES:

1.Roof curb must be set up for unit being installed.

2.Seal strip must be applied, as required, to unit being installed.

3.Roof curb is made of 16-gauge steel.

4.Attach ductwork to curb (flanges of duct rest on curb).

5.Insulated panels: 1-in. (25.4 mm) thick fiberglass 1 lb. density.

6.When unit mounting screw is used (see Note A), a retainer bracket must be used as well. This bracket must also be used when required by code for hurricane or seismic conditions. This bracket is available through Micrometl.

10

Image 10
Contents Efficient operation FEATURES/BENEFITSConvertible duct configuration Durable, dependable componentsTable of Contents Model Number Nomenclature ARI* Capacities Weighted Sound Power dBACooling Capacities and Efficiencies Physical Data Physical Data-Unit 50XPField-installed accessories Options and AccessoriesFactory-installed options Electric HeatersEconomizer Unit Dimensions 50XP024-036 Unit Dimensions 50XP042-060 Accessory Roof Curb 50XP024-060 Ordering Number50XP Unit Suggested Rigging Selection Procedure with ExampleSelect unit that corresponds to power source available Select unit based on required cooling capacityPerformance Data 50XP024Performance Data Cont 50XP036 50XP04250XP048 Cooling Notes Filter Pressure Drop Table IN. W.C Economizer 1-in. Filter Pressure Drop IN. W.CMultiplication Factors Electric Heat Pressure Drop Tables IN. W.C Small CabinetTypical Piping and Wiring Application Data Mocp Electrical DataFLA MCA MIN MAX RLA LRA FLATypical Wiring Schematic 208/230-1-60 Typical Wiring Schematic 208/230-3-60 Controls Operating sequenceGuide Specifications Special Features Catalog No 50XP---05PD

50XP specifications

The Carrier 50XP is a high-efficiency air conditioning unit designed for residential and light commercial applications. It is known for its reliability, advanced features, and energy efficiency, making it a popular choice among homeowners and contractors alike. This unit integrates state-of-the-art technology to provide optimal indoor comfort regardless of external weather conditions.

One of the main features of the Carrier 50XP is its efficient cooling and heating capability. The unit utilizes a scroll compressor, which is renowned for its durability and ability to deliver consistent performance. This type of compressor operates quietly and efficiently, contributing to lower energy costs while providing substantial cooling output.

The 50XP model is equipped with a multi-speed blower motor, which allows for precise control over airflow delivery. This feature ensures that air is distributed evenly throughout the space, enhancing comfort levels. Additionally, the unit supports variable speed operation, which further optimizes energy consumption while maintaining desired indoor temperatures.

Another significant characteristic of the Carrier 50XP is its advanced refrigerant technology. The unit is designed to use environmentally friendly refrigerants, aligning with modern standards for sustainability and reduced environmental impact. This eco-conscious approach not only complies with regulatory guidelines but also promotes higher energy efficiency across its operational lifespan.

The 50XP also features advanced communication capabilities, allowing it to integrate seamlessly with Carrier's smart home technology. This connectivity empowers users to remotely control their HVAC system, monitor energy usage, and receive maintenance alerts. Such smart technology enhances convenience and efficiency, enabling users to manage their indoor climate more effectively.

Noise reduction is a critical consideration in residential and light commercial units, and the Carrier 50XP excels in this aspect. With an insulated chassis and specially designed fan blade, the unit minimizes operational noise, ensuring a quiet environment during its operation.

In conclusion, the Carrier 50XP is a powerful and efficient air conditioning unit that showcases the latest advancements in HVAC technology. Its reliable performance, energy efficiency, and innovative features make it an ideal option for those looking to improve their indoor comfort while keeping energy costs low. With sustainable refrigerant options and smart home integration, the 50XP represents Carrier's commitment to quality, efficiency, and environmental responsibility.