Emerson DA-100 operation manual Specification, Installation, Operations, - 4 -

Page 4

SPECIFICATION

Max. Air Pressure:

0.69MPa (6.9 bar)

 

Max. Fluid Pressure:

0.69MPa (6.9 bar)

 

Cylinder Air Pressure:

Min. 0.35MPa (3.5 bar)

 

Max. 0.50MPa (5.0 bar)

Weight:

480g

 

Gun Stud Diameter:

16.0mm

 

Fluid Thread:

G1/4 (M)

CAP Thread: G1/4 (M)

CYL Thread:

G1/4 (M)

 

INSTALLATION

Figure 1. Dimensions

Mount the gun with the set screw (22).

NOTE:

The air supplied to the gun should be clean air that removed any impurities. Also, the air hose should have enough inner diameter depending on the length to supply necessary air.

OPERATIONS

1.Mix, prepare and strain the coating material to be sprayed according to paint manufacture’s instructions.

2.Adjust the CYL air at 0.35 Mpa ~. Please use air regulator for setting the air pressure for the smooth movement of CYL.

3.Turn Needle Adjusting Knob counter-clockwise 3.5 turns from fully closed position. This makes the Needle fully opened.

4.Adjust CAP air at 0.20Mpa.

5.Adjust fluid pressure at about 0.07Mpa~0.1Mpa.

6.Turn on CYL air and test spray. Adjust fluid and air pressure until desired pattern is obtained. Pattern size can be adjusted by using pattern valve (5). Control fluid pressure at supply source. Always attempt to keep CAP pressure as low as possible to minimize overspray and control the air at air supply source.

WARNING

Risk of injury. Equipment and fluid may be under pressure. Pressure in the system must be relieved before beginning the cleaning procedure and before replacing any parts. Follow the procedures in the literature provided with the system.

4

Image 4
Contents Description Models- 1 - EquipmentSaftey Precaustions - 2 -- 3 - MisuesSpecification InstallationOperations - 4 -Replacement Cleaning- 5 - - 6 - Gun Exploded View Parts SheetAccessories - 7 -Normal Spray Pattern Part Number Description