Hitachi AA 2000 dimensions Solid Stream Spray Tips

Page 19

Spray Tip and Air Cap Selection Charts

SOLID STREAM SPRAY TIPS

For use in applications requiring a solid stream of fluid such as with mastics or sealers. All these tips require Air Cap 218±336.

Orifice Size

 

 

inches (mm)

Part No.

Pattern

0.027 (0.689)

182±027

Solid stream,

0.029 (0.737)

182±029

approximately

0.25" (6.35 mm)

0.031 (0.787)

182±031

 

0.033 (0.838)

182±033

 

0.035 (0.889)

182±035

 

0.037 (0.940)

182±037

 

0.039 (0.991)

182±039

 

0.041 (1.041)

182±041

 

0.043 (1.092)

182±043

 

0.045 (1.143)

182±045

 

0.047 (1.194)

182±047

 

 

 

 

FINE FINISH SPRAY TIPS

For use in application of certain urethanes, clearcoats, and light-weight air-dry enamels. All these tips require replace- ment of standard diffuser-seat with Diffuser-seat part no. 223±139.

 

Light Viscosity

Fan Width at

Fine Finish

Orifice Size

fl oz/min*

12º (300 mm)

Spray Tip

inches (mm)

(liters/min)

inches (mm)

Part No.

 

 

 

 

 

0.012 (0.305)

10.0

(0.3)

6±8

182±312

 

 

 

(152±203)

 

 

 

 

 

 

0.014 (0.356)

13.6

(0.4

6±8

182±314

 

 

 

(152±203)

 

 

 

 

 

 

0.012 (0.305)

10.0

(0.3)

10±12

182±512

 

 

 

(250±300)

 

 

 

 

 

 

0.014 (0.356)

13.6

(0.4

10±12

182±514

 

 

 

(250±300)

 

 

 

 

 

 

0.016 (0.406)

17.0

(0.5)

10±12

182±516

 

 

 

(250±300)

 

 

 

 

 

 

0.018 (0.457)

20.9

(0.6)

10±12

182±518

 

 

 

(250±300)

 

 

 

 

 

 

0.020 (0.508)

25.8

(0.8)

10±12

182±520

 

 

 

(250±300)

 

 

 

 

 

 

*Fluid output at 600 psi (41 bar).

AIR CAPS

 

Tip Size

 

 

 

 

 

 

Used With

Air

 

Application

inches (mm)

Consumption

Part No.

 

 

 

 

 

smaller than

 

217±303{

Standard

0.025 (0.635)

3±5 scfm

 

0.027 (0.689)

 

218±336

Standard

and larger

3±5 scfm

 

smaller than

 

219±093{{

Fine Finish

0.025 (0.635)

5±7 scfm

 

smaller than

 

219±094

High Solids

0.025 (0.635)

5±7 scfm

 

 

 

 

Fine Finish

 

 

 

with Pattern

smaller than

 

222±507

Adjustment

0.025 (0.635)

5±7 scfm

High

smaller than

 

222±607

Atomization

0.025 (0.635)

5±7 scfm

High Effi-

 

 

 

ciency Low

smaller than

 

222±608

Pressuret

0.025 (0.635)

5±7 scfm

 

 

 

 

{Air cap provided with spray gun.

{{The pattern adjustment valve must be open (turned fully clockwise) when using this air cap.

307-586 19

Image 19
Contents 307±586 Table of ContentsInjection Hazard Equipment Misuse Hazard Typical Installation InstallationVentilate the Spray Booth Connect the Fluid Line Connect the Air LineFluid supply container Ground it according to local code Ground the SystemPressure Relief Procedure SafetyOperation How the Air-Assisted Airless Spray Gun Operates Install a Spray TipSelect a Spray Tip and Air Cap Apply the Fluid Adjust the Spray PatternCheck the Diffuser-seat Operation Weekly Clean the Spray Gun and System DailyFlush the Gun Daily Problem Cause Solution TroubleshootingGeneral Troubleshooting Spray Pattern Troubleshooting307-586 Air Valve Service ServiceFluid Packing Replacement A50 AIR Service NotesFor Direct Hose Connection PartsDescription Qty Use Only Genuine Graco Parts and AccessoriesStandard Spray Tips Spray Tip and Air Cap Selection ChartsSolid Stream Spray Tips Accessories Technical Data DimensionsPage 307-586 To you 1±800±367±4023 Toll Free Graco Warranty and DisclaimersGraco Phone Number Manual Change Summary