Hitachi AA 2000 dimensions Spray Tip and Air Cap Selection Charts, Standard Spray Tips

Page 18

Spray Tip and Air Cap Selection Charts

STANDARD SPRAY TIPS

 

 

*Light to

 

 

Orifice

Inches (mm)

Medium

*Heavy

 

Size

Fan Width

Viscosity

Viscosity

 

inches

at 12º

fl oz/min

fl oz/min

Part

(mm)

(300 mm)

(liters/min)

(liters/min)

No.

 

 

 

 

 

0.007

2±4 (50±100)

4.0

 

182±107

(0.178)

4±6 (100±150)

(0.1)

 

182±207

 

6±8 (150±200)

 

 

182±307

 

 

 

 

 

0.009

4±6 (100±150)

7.0

 

182±209

(0.229)

6±8 (150±200)

(0.2)

 

182±309

 

8±10(200±250)

 

 

182±409

 

 

 

 

 

0.011

4±6 (100±150)

10.0

 

182±211

(0.279)

6±8 (150±200)

(0.3)

 

182±311

 

8±10 (200±250)

 

 

182±411

 

10±12 (250±300)

 

 

182±511

 

12±14 (300±350)

 

 

182±611

 

 

 

 

 

0.013

4±6 (100±150)

13.0

 

182±213

(0.330)

6±8 (150±200)

(0.4)

 

182±313

 

8±10 (200±250)

 

 

182±413

 

10±12 (250±300)

 

 

182±513

 

12±14 (300±350)

 

 

182±613

 

 

 

 

 

0.015

4±6 (100±150)

17.0

 

182±215

(0.381)

6±8 (150±200)

(0.5)

 

182±315

 

8±10 (200±250)

 

 

182±415

 

10±12 (250±300)

 

 

182±515

 

12±14 (300±350)

 

 

182±615

 

 

 

 

 

0.017

4±6 (100±150)

22.0

17.0

182±217

(0.432)

6±8 (150±200)

(0.7)

(0.5)

182±317

 

8±10 (200±250)

 

 

182±417

 

10±12 (250±300)

 

 

182±517

 

12±14 (300±350)

 

 

182±617

 

 

 

 

 

0.019

6±8 (150±200)

28.0

21.0

182±319

(0.483)

8±10 (200±250)

(0.8)

(0.6)

182±419

 

10±12 (250±300)

 

 

182±519

 

12±14 (300±350)

 

 

182±619

 

14±16 (350±400)

 

 

182±719

 

 

 

 

 

0.021

8±10 (200±250)

35.0

27.0

182±421

(0.533)

10±12 (250±300)

(1.0)

(0.8)

182±521

 

12±14 (300±350)

 

 

182±621

 

14±16 (350±400)

 

 

182±721

 

16±18 (400±460)

 

 

182±821

 

 

 

 

 

0.023

8±10 (200±250)

40.0

34.0

182±423

(0.584)

10±12 (250±300)

(1.2)

(0.97)

182±523

 

12±14 (300±350)

 

 

182±623

 

14±16 (350±400)

 

 

182±723

 

16±18 (400±460)

 

 

182±823

 

 

 

 

 

0.025

8±10 (200±250)

50.0

42.0

182±425

(0.635)

10±12 (250±300)

(1.5)

(1.2)

182±525

 

12±14 (300±350)

 

 

182±625

 

14±16 (350±400)

 

 

182±725

 

16±18 (400±460)

 

 

182±825

 

 

 

 

 

 

 

*Light to

 

 

Orifice

Inches (mm)

Medium

*Heavy

 

Size

Fan Width

Viscosity

Viscosity

 

inches

at 12º

fl oz/min

fl oz/min

Part

(mm)

(300 mm)

(liters/min)

(liters/min)

No.

 

 

 

 

 

**0.027

8±10 (200±250)

58.5

50.0

182±427

(0.689)

12±14 (300±350)

(1.7)

(1.4)

182±627

 

 

 

 

 

**0.029

8±10 (200±250)

68.0

59.0

182±429

(0.737)

12±14 (300±350)

(1.9)

(1.7)

182±629

 

14±16 (350±400)

 

 

182±729

 

 

 

 

 

**0.031

8±10 (200±250)

78.0

69.0

182±431

(0.787)

12±14(300±350)

(2.2)

(2.0)

182±631

 

 

 

 

 

**0.035

8±10 (200±250)

98.0

89.0

182±435

(0.889)

10±12 (250±300)

(2.8)

(2.5)

182±535

 

12±14 (300±350)

 

 

182±635

 

 

 

 

 

**0.039

8±10 (200±250)

118.0

109.0

182±439

(0.991)

10±12 (250±300)

(3.4)

(3.1)

182±539

 

12±14 (300±350)

 

 

182±639

 

 

 

 

 

**0.041

8±10 (200±250)

138.0

129.0

182±441

(1.041)

10±12 (250±300)

(4.0)

(3.7)

182±541

 

12±14 (300±350)

 

 

182±641

**0.043

8±10 (200±250)

158.0

149.0

182±443

(1.092)

10±12 (250±300)

(4.6)

(4.3)

182±543

 

12±14 (300±350)

 

 

182±643

*Fluid output at 600 psi (41 bar).

**Requires air cap 218±336.

Fluid output (Q) at other pressures (P) can be calculated by this formula: Q = (0.041) (QT) (P ).

Where QT = Fluid output (fl oz/min) from the above table for the selected orifice size.

NOTE: Other tips are available on special work order. Allow 4 to 6 weeks for delivery.

1￿￿￿￿￿￿￿￿￿

Image 18
Contents Table of Contents 307±586Injection Hazard Equipment Misuse Hazard Installation Typical InstallationVentilate the Spray Booth Connect the Air Line Connect the Fluid LineGround the System Fluid supply container Ground it according to local codeSafety Pressure Relief ProcedureOperation Install a Spray Tip How the Air-Assisted Airless Spray Gun OperatesSelect a Spray Tip and Air Cap Adjust the Spray Pattern Apply the FluidClean the Spray Gun and System Daily Check the Diffuser-seat Operation WeeklyFlush the Gun Daily Spray Pattern Troubleshooting TroubleshootingGeneral Troubleshooting Problem Cause Solution307-586 Service Air Valve ServiceFluid Packing Replacement AIR Service Notes A50Parts For Direct Hose ConnectionUse Only Genuine Graco Parts and Accessories Description QtySpray Tip and Air Cap Selection Charts Standard Spray TipsSolid Stream Spray Tips Accessories Dimensions Technical DataPage 307-586 Manual Change Summary Graco Warranty and DisclaimersGraco Phone Number To you 1±800±367±4023 Toll Free