Hitachi 309411E Control Board, Pressure Control Transducer, Pressure Adjust Potentiometer

Page 14

Pressure Control

Control Board

Removal

1.

Relieve pressure; page 6.

2.Fig. 10. Remove four screws (11) and display/cover (12). Pull display connector wings open on PC board and pull display connector out.

3.Fig. 17. Disconnect at control board (147):

DLead (D) from potentiometer.

DLead (E) from transducer.

DRemove ON/OFF switch (51) at connector (A).

4.Fig. 10. Remove six screws (44) from control board (147) and green ground wire.

5.Remove connector (Ref 4) at backside of pressure control. Remove jam nut (147a) and control board (147).

Installation

When installing replacement control board, follow instructions with control board to set model type.

1.Fig. 10. Install control board (147) and jam nut (147a). Install connector (Ref 4) at backside of pressure control.

2.Install green ground wire and control board (147) with six screws (44).

3.Fig. 17. Connect to control board (147):

DConnect ON/OFF switch (51) connector (A).

DLead (E) to transducer.

DLead (D) to potentiometer.

4.Fig. 10. Push display connector into PC board close display connector wings on PC board. Install display/cover (12) with four screws (11).

Pressure Control Transducer

Removal

1.

Relieve pressure; page 6.

2.Fig. 10. Remove four screws (11) and display/cover (12).

3.Disconnect lead (E) from control board (147).

4.Remove two screws (141) and transducer guard (178) from control housing (8). Pull transducer connector through rubber grommet (176).

5.Remove pressure control transducer (100q) and o-ring (100p) from filter housing (100e).

Installation

1.Fig. 10. Install o-ring (100p) and pressure control transducer (100q) in filter housing (100e). Torque to 30–36 ft-lb.

2.Install transducer connector and rubber grommet

(176)in control housing (8) . Install transducer guard (178) on control housing with two screws

(141).

3.Connect lead (E) to control board (147).

4.Install display/cover (12) with four screws (11).

Pressure Adjust Potentiometer

Removal

1.

Relieve pressure; page 6.

2.Fig. 10. Remove four screws (11) and display/cover (12).

3.Disconnect lead (D) from control board (147).

4.Loosen set screws on potentiometer knob (13) and remove knob, shaft nut, lockwasher (22) and pressure adjust potentiometer (22).

5.Remove seal (78) from potentiometer (22).

Installation

1.Install seal (33) on potentiometer (22).

2.Fig. 10. Install pressure adjust potentiometer (22), shaft nut, lockwasher (22) and potentiometer knob (13).

a.Turn potentiometer shaft (22) clockwise to internal stop. Assemble potentiometer knob (13) to strike pin on plate (50).

b.After adjustment of step a., tighten both set screws in knob 1/4 to 3/8 turn after contact with shaft.

3.Connect lead (D) to control board (147).

4.Install display/cover (12) with four screws (11).

14309411

Image 14
Contents 233709 This manual contains importantModel Series Description Table of Contents Skin Injection Hazard Fire and Explosion Hazard Component Identification and Function Spray Gun Trigger Lock Reference your Spray Gun ManualMaintenance Pressure Relief ProcedureTroubleshooting Problem Cause SolutionTions Removal Bearing Housing and Connecting RodInstallation Drive Housing Pinion Assembly/Rotor/Shaft/Clutch/Pulley Bottom View10. Do Drive Housing, Installation On/Off Switch Control Board Pressure Adjust PotentiometerPressure Control Pressure Control TransducerDigital Display Messages After a fault, follow these steps to restart sprayerPressure Control Repair Displacement Pump Repair309411 Parts Basic Sprayer Model 233709, Series aDescription Qty Engine Detail Parts List & Drawing Pinion Assembly Ref NoRef No Pressure Control Assembly Parts Drawing SprayerParts List Sprayer Description QTYModel 233710 Parts List & Drawing -Clutch AssemblyParts Complete Sprayer Parts Lo-Boy Suction Set Kit Technical DataDimensions Graco Standard Warranty Distributor near you1-800-690-2894 Toll Free