Graco 900, 1250 Shutdown and Cleanup, Texture Spraying Gallon Material Hopper

Page 12

Shutdown and Cleanup

Shutdown and Cleanup

Keep pump and hose clean when switching between simulated acoustic, knockdown and orange peel applications. A dirty pump can release particles of texture into the finish.

CAUTION

To increase pump life, turn power off when not spraying.

Before removing material hose be sure pressure is relieved and material is not in hose.

To keep unit in good operating condition, always clean it thoroughly and prepare it properly for storage.

7.Spray inside material hopper to circulate water through gun and hose. While circulating water, use

gun to clean material hopper.

Texture Spraying

(8-10 gallon Material Hopper)

When you have finished spraying:

1. Open gun air valve.

ti8528a

2.Make sure hopper gun/spray gun selection switch is turned to SPRAY GUN.

ti9219a

3. Turn power switch ON.

ti9222a

4.Close gun air valve.

5.Trigger gun into bucket until most of texture mix is pumped out.

6.Fill material hopper with 2-4 gallons of clean water.

ti9084a

8.Partially open gun air valve to use air to achieve bet- ter cleaning results.

9.Spray water into a waste bucket to empty material hopper.

A soft brush can be used to loosen dried on material.

10.Turn power switch OFF.

11.Open gun air valve. Relieve Pressure, page 6.

CAUTION

If water freezes in unit damage may occur. In cold weather store system where it will not freeze.

12

Image 12
Contents Models 254974 Related Manuals311777 311772 Fire and Explosion Hazard Equipment Misuse HazardBurn Hazard Electric Shock HazardPressurized Equipment Hazard Ti9010a Component Identification Model 254975 ShownComponent Preparation Setup Texture Spraying material supplied from unitTouch Up Hopper Attachment PER GUN Mixing Material Dry Mix 40 lb 18 kg bagPremix Spray Techniques Shutdown and Cleanup Texture Spraying Gallon Material HopperTouch-up Hopper Attachment Transporting the SprayerRemoving Material Hopper From Sprayer To ReassembleTroubleshooting Problem Cause SolutionRelieve Pressure, page 6. Remove Relieve Pressure, page 6. Clean Technical Data Dimensions RTXGraco Warranty Graco Headquarters Minneapolis