Carrier 42 SERIES specifications

Page 17

LEGEND For Fig. 1

Component Sizing Ð 1¤2 nominal (for 5¤8 OD copper tubing) or 3¤4 nominal (for 7¤8 OD copper tubing).

Manual Air Vent Ð Standard component - Brazed into high point of hydronic cooling and/or heating coil circuit.

Automatic Air Vent Ð Brazed into high point of coil circuit.

Coil Connections (Positions A & B) Ð When isolation valve only is added to supply or return line, the isolation valve will be factory brazed to the coil stub-out. Addition of any other component or connection to the supply or return line will change the respective coil connection(s) to one of the following:

STANDARD: Swage ®tting for ®eld braze.

OPTION: Union(s) added by factory for ®eld connection.

Service Fittings (Positions C & D) Ð Optional ®ttings for attaching pressure/temperature sensing devices to obtain pressure drop or temperature differential accross coil. Used with ball valve or balance valve where extremely accurate water ¯ow balancing is required.

GAGE COCK: Pressure test only - In supply and return lines.

PRESSURE TEST PORT: Pressure test only - In supply and return lines.

INSERTION TEST PORT: Pressure/Temperature test - In supply and return lines.

Water Flow Balancing (Positions E, F, & H) Ð Only one device per total valve package to be used for balancing water ¯ow through the coil. When isolation valve (ball valve or ball valve with memory stop at positionH) is used for water ¯ow balancing, do not specify additional balancing device at positionE or F. When balancing device is speci®ed at position E or F, isolation valve does not require balancing feature at position H (See exception, 3-way motorized valve).

CIRCUIT SETTER: May serve as a positive shut-off valve in lieu of isolation valve at position H (check service requirements).

BALANCING VALVE: Check speci®cations for service ®tting requirements.

FIXED FLOW: No balancing required - When there are more devices on the supply line of the valve package than on the return line, the factory may move this device to position E to ®t valve package within allotted space. Consult your factory representative to match the available ®xed ¯ow valve to your job requirements.

Strainer (Position G) Ð Does not include blow down ®tting and should not be used in lieu of main piping strainers.

Isolation Valves (Positions H & J) Ð Normally requires one each on supply and return line (see exception under circuit setter). When position H is used for balancing (ball vall or ball valve with memory stop), check speci®cations for service valve requirements.

GATE VALVE: Shut-off only - Do not use for balancing.

BALL VALVE: Shut-off/balance - No memory stop.

BALL VALVE WITH MEMORY STOP: Shut-off/balance - Memory stop allows re-opening to balance point after usage as a shut-off.

17

Image 17
Contents Application Data Contents Pipe Control Selection GuideThermostatic Fan Control, 2-Pipe Systems Ð Standard Wiring PackagesOnly Thermostatic Electric Valve Control, 2-Pipe ÐUnit Location Wiring Package Electric Type Unit Location Wiring Package Electric Type Unit Type Location Wiring Package Electric Heater Electrical Data Electric HeatHeater Construction Thermostat Electrical Data Pilot Duty Ð 125 VA Combination Thermostat/3-Speed SwitchREMOTE-MOUNTED Controls Thermostat and Fan Switch Electrical Ratings Fan SwitchAlternate Wall Thermostats Thermostat Electrical Ratings Amperes Thermostat Valve LoadMED Combination Thermostat/ON-OFF Toggle SwitchUNIT-MOUNTED Controls Thermostat Electrical Data Pilot Duty Ð 125 VA at 120-277 Standard 2-pipe units will be the same end connection Basic DefinitionsField Piping Connections Hydronic Coil ArrangementValve Packages Symbol And Placement Of ValvesPage Valve Packages Two-Way Motorized Control Valve No Motorized Control Valve Three-Way Motorized Control ValveValve Package Arrangements Page Description Valve Package ArrangementsCapacity Acceptable Field-Furnished Pneumatic ValvesPiping Components SYMBOL/SKETCH Description CV Factor Rating Steam PSI USEHayes Compression Stop Valve Piping ComponentsUSE SYMBOL/SKETCH Description CV Factor Rating SteamWAY Motorized Valve Electric WAY Pneumatic ValveFormula Example CV Factor vs Water Pressure DropGraph Example Page Joint Materials Copper Water Tube and Joint Material Pressure RatingsExample Correction Factors for GlycolEquivalent water ¯ow method for all 42 Series Models Cabinet Changes Standard Accessories and Options

42 SERIES specifications

The Carrier 42 SERIES represents a cutting-edge solution in the realm of HVAC systems, meticulously designed to provide efficient heating, cooling, and ventilation for residential and commercial spaces. Known for their reliability and superior performance, these units combine advanced technologies with user-friendly features, catering to diverse climate needs.

One of the standout features of the Carrier 42 SERIES is its energy efficiency. These units are equipped with high Seasonal Energy Efficiency Ratings (SEER) and Heating Seasonal Performance Factor (HSPF) ratings, which translate to reduced energy consumption and lower utility bills. The use of advanced inverter technology allows the compressor to adjust its speed and output according to the precise heating or cooling needs of a space, ensuring optimal comfort while minimizing energy waste.

In terms of operation, the Carrier 42 SERIES includes a variable speed compressor that not only enhances comfort but also ensures quieter operation. Unlike traditional systems, these units can run at lower speeds for longer periods, resulting in a more consistent indoor climate without the disruptive noise typically associated with HVAC systems.

Another significant aspect of the Carrier 42 SERIES is its robust construction and advanced materials. Built with durability in mind, these units feature weather-resistant cabinets and enhanced corrosion protection, ensuring a longer lifespan and reliable performance even in harsh environmental conditions.

Smart connectivity is also a hallmark of the Carrier 42 SERIES. Many models come with integrated Wi-Fi capabilities, allowing users to control their heating and cooling systems remotely via mobile apps. This feature enables homeowners to manage their indoor climate settings from anywhere, enhancing convenience and energy savings.

Furthermore, the Carrier 42 SERIES incorporates advanced air filtration systems designed to improve indoor air quality. These systems capture dust, allergens, and other airborne pollutants, contributing to a healthier living environment.

Overall, the Carrier 42 SERIES emerges as an exceptional choice for anyone seeking a reliable, efficient, and technologically advanced HVAC system. With its focus on energy efficiency, quiet operation, durability, smart home integration, and air quality improvement, it meets the demands of modern users while ensuring comfort throughout the year.