Table 1 Ð Acceptable Field-Furnished Pneumatic Valves

MANUFACTURER

VALVE NUMBER

TYPE

MODE

SIZE (in.)

CAPACITY

(OD Male Flare)

(CV) RATING

 

 

 

 

 

VP517A

3-WAY

MIXING

7¤8

3.0, 4.0, 6.3

 

VP522A&B

3-WAY

SEQUENCING

5¤8 or 7¤8

1.6/2.5 or 2.5/3.5/4.0

 

VP526A

3-WAY

MIXING

5¤8

1.6,

2.5

HONEYWELL

VP527A

2-WAY

N.O.

1¤2

0.63, 1.0, 1.6

 

VP513A

2-WAY

N.O.

5¤8 or 7¤8

2.5,

4.0

 

VP513B

2-WAY

N.C.

5¤8

1.0, 1.6, 2.5

 

VP531A

2-WAY

N.O.

5¤8 or 7¤8 (ODS)

1.6, 2.6, 3.3

 

V4332

3-WAY

MIXING

1¤2

1.2,

2.0

 

V4334

3-WAY

MIXING

5¤8

4.7

JOHNSON

V4440

3-WAY

SEQUENCING

1¤2

1.4,

2.4

SERVICE

V4440

3-WAY

SEQUENCING

5¤8

4.1,

4.7

 

V3766

2-WAY

N.O.

1¤2

1.0, 1.7, 3.2

 

V3966

2-WAY

N.C.

1¤2

1.7,

3.2

 

VK9312

3-WAY

MIXING

5¤8

2.0,

4.0

BARBER-

VK9332

3-WAY

SEQUENCING

5¤8

1.7, 2.4, 4.0

COLEMAN

VK9212

2-WAY

N.O.

5¤8

0.4, 1.3, 2.2, 3.3

 

VK9222

2-WAY

N.C.

5¤8

0.4, 1.3, 2.2, 3.3

 

VP656-0011, 10, 09

3-WAY

MIXING

1¤2

1.5, 2.5

 

VP658-0004, 5

3-WAY

DIVERTING

1¤2

2.5

MCC

VP658-0050, 51

3-WAY

SEQUENCING

1¤2

1.5, 2.5

POWERS

VP658-0004, 5

2-WAY

N.O.

1¤2

1.0, 2.5

 

VP656-0002, 4

2-WAY

N.O.

1¤2

0.9, 2.1

 

VP656-0012

2-WAY

N.C.

1¤2

2.1

 

2582 (V8200)

2-WAY

N.O.

1¤2

0.4, 0.6, 1.0, 1.6

 

2583 (V8300)

3-WAY

MIXING

1¤2

1.6

 

2561 (V6101)

2-WAY

N.C.

1¤2, 5¤8

1.2, 2.2, 4.1

ROBERTSHAW

2561 (V6102)

2-WAY

N.O.

1¤2

1.0, 1.6

2563 (V6300)

3-WAY

MIXING

1¤2

1.6

 

 

2563 (V6301)

3-WAY

MIXING

5¤8

2.5

 

2569 (V6900, 01)

3-WAY

SEQUENCING

1¤2, 5¤8, 7¤8

.6, 1.0, 1.1, 1.6,

 

2.5, 3.2, 2.4, 4.0, 4.5

 

 

 

 

 

CV

Ð See Note 5.

N.C.

Ð

Normally Closed

N.O.

Ð

Normally Open

OD

Ð Outside Diameter

NOTES:

1. This reference table lists valves that are acceptable because of capacity and piping connection type. Actual valve selection for spe-

ci®c mode (N.O. or N.C.) and capacity rating (C ) to meet jobsite

V

conditions must be made by ®eld personnel.

2.Valve size (1¤2-, 5¤8-, and 7¤8-in. OD) designates the matching tub- ing size.

Use price page package 18-2 or 18-4 for selecting 1¤2-in. or 5¤8-in. OD valves. Use price page package 18-3 or 18-5 for 7¤8-in. OD valves.

3.The 1¤2-in. and 5¤8-in. OD valves are used primarily on 42C (ceiling) and 42V (vertical) room fan coil units. The 7¤8-in. OD valves are recommended for use on 42D (ducted) units.

4.Flare connections are 45° SAE ¯are with body threaded for stand- ard ¯are nuts.

5.The CV capacity rating is the gpm ¯ow through a valve at 1.0 psi pressure drop.

EXAMPLE: A 2.5 CV valve has a ¯ow of 2.5 gpm at 1.0 psi pres- sure drop.

As ¯ow changes, pressure drop can be determined by the formula:

Actual gpm 2

P =

CV

6.Restrictions imposed by limited piping enclosures often require that the valve manufacturer's recommendation for obstruction free serv- ice clearances be waived. Service/isolation valves normally speci- ®ed will permit removal of the entire pneumatic valve for ®eld serv- ice if necessary.

7.Certain combinations of piping accessories and control valves have proven unacceptable in the past, therefore the factory must re- serve the right of review for ®nal acceptance.

8.Consult factory on all applications involving valves with thermo- static actuators or built in pneumatic thermostats.

23

Image 23
Contents Application Data Contents Pipe Control Selection GuideThermostatic Fan Control, 2-Pipe Systems Ð Standard Wiring PackagesOnly Thermostatic Electric Valve Control, 2-Pipe ÐUnit Location Wiring Package Electric Type Unit Location Wiring Package Electric Type Unit Type Location Wiring Package Electric Heater Electrical Data Electric HeatHeater Construction Thermostat Electrical Data Pilot Duty Ð 125 VA Combination Thermostat/3-Speed SwitchREMOTE-MOUNTED Controls Thermostat Electrical Ratings Amperes Thermostat Valve Load Fan SwitchThermostat and Fan Switch Electrical Ratings Alternate Wall ThermostatsMED Combination Thermostat/ON-OFF Toggle SwitchUNIT-MOUNTED Controls Thermostat Electrical Data Pilot Duty Ð 125 VA at 120-277 Standard 2-pipe units will be the same end connection Basic DefinitionsField Piping Connections Hydronic Coil ArrangementValve Packages Symbol And Placement Of ValvesPage Valve Packages Two-Way Motorized Control Valve No Motorized Control Valve Three-Way Motorized Control ValveValve Package Arrangements Page Description Valve Package ArrangementsCapacity Acceptable Field-Furnished Pneumatic ValvesPiping Components SYMBOL/SKETCH Description CV Factor Rating Steam PSI USEHayes Compression Stop Valve Piping ComponentsWAY Pneumatic Valve SYMBOL/SKETCH Description CV Factor Rating SteamUSE WAY Motorized Valve ElectricFormula Example CV Factor vs Water Pressure DropGraph Example Page Joint Materials Copper Water Tube and Joint Material Pressure RatingsExample Correction Factors for GlycolEquivalent water ¯ow method for all 42 Series Models Cabinet Changes Standard Accessories and Options

42 SERIES specifications

The Carrier 42 SERIES represents a cutting-edge solution in the realm of HVAC systems, meticulously designed to provide efficient heating, cooling, and ventilation for residential and commercial spaces. Known for their reliability and superior performance, these units combine advanced technologies with user-friendly features, catering to diverse climate needs.

One of the standout features of the Carrier 42 SERIES is its energy efficiency. These units are equipped with high Seasonal Energy Efficiency Ratings (SEER) and Heating Seasonal Performance Factor (HSPF) ratings, which translate to reduced energy consumption and lower utility bills. The use of advanced inverter technology allows the compressor to adjust its speed and output according to the precise heating or cooling needs of a space, ensuring optimal comfort while minimizing energy waste.

In terms of operation, the Carrier 42 SERIES includes a variable speed compressor that not only enhances comfort but also ensures quieter operation. Unlike traditional systems, these units can run at lower speeds for longer periods, resulting in a more consistent indoor climate without the disruptive noise typically associated with HVAC systems.

Another significant aspect of the Carrier 42 SERIES is its robust construction and advanced materials. Built with durability in mind, these units feature weather-resistant cabinets and enhanced corrosion protection, ensuring a longer lifespan and reliable performance even in harsh environmental conditions.

Smart connectivity is also a hallmark of the Carrier 42 SERIES. Many models come with integrated Wi-Fi capabilities, allowing users to control their heating and cooling systems remotely via mobile apps. This feature enables homeowners to manage their indoor climate settings from anywhere, enhancing convenience and energy savings.

Furthermore, the Carrier 42 SERIES incorporates advanced air filtration systems designed to improve indoor air quality. These systems capture dust, allergens, and other airborne pollutants, contributing to a healthier living environment.

Overall, the Carrier 42 SERIES emerges as an exceptional choice for anyone seeking a reliable, efficient, and technologically advanced HVAC system. With its focus on energy efficiency, quiet operation, durability, smart home integration, and air quality improvement, it meets the demands of modern users while ensuring comfort throughout the year.