Graco 288048 important safety instructions Service, Disassembly

Page 17

Service

Follow the Service Notes in Figs. 8 and 9 when reassembling the gun.

Gun repair kits are available. See page 18. Refer- ence numbers marked with an asterisk (*) in the service procedures are included with the 288171 Air Seal Repair Kit. Reference numbers marked with a symbol (†) in the service procedures are included with the 288137 Fluid Repair Kit.

Disassembly

1.Follow Pressure Relief Procedure, page 11.

2.Unscrew the four screws (14) and remove the gun from the manifold.

3.Unscrew the tip retainer nut (7). Remove the spray tip (9) and gasket (8). See Figs. 8 and 9.

4.Remove the cap (18) from the piston housing (1). Remove the springs (20 and 19).

5.Using the supplied wrench (34), loosen the fluid needle setscrew (16). Remove the needle stop (17).

6.Remove the seat (10, 41).

CAUTION

Be sure to keep the needle straight when removing it from the gun. If the needle is bent it must be replaced.

7.Pull the needle assembly (12) straight out the front of the gun. Remove the o-rings (31) from the fluid needle (12).

8.Remove the gasket (11).

CAUTION

Install a new gasket (11) whenever you remove the seat (10, 41) from the gun. Failure to install a new gasket may result in fluid leaking into the air chamber.

Service

9.Remove the piston. Using a pliers, pull the piston (21) out of the piston housing (1).

10.If necessary, unscrew the two screws (15) holding the fluid housing (2) to the piston housing (1). If worn, remove the gasket (13) from the bottom of the piston housing.

15

2

38

(model 288554 only)

15

1

TI8197a

FIG. 12

11.Remove the large o-ring (22) from the piston and the smaller o-ring (23) from the piston shaft. Remove the two o-rings (25, 26) from each of the piston stems. Check that the stems are solidly in place. If they are loose, replace the entire piston assembly (21).

12.Perform the following applicable step:

Non-circulating Paint Guns: Remove the fluid outlet port plug (4) and gasket (3) from the fluid housing (2). Remove the o-ring (5) and backup

(6) from the plug.

Circulating Paint Guns: Remove the gasket (3) from the fluid housing (2).

Sealant Gun: Remove the gasket (3).

13.Clean all parts and replace any worn parts. When assembling, lubricate the threads with anti-seize lubricant.

311053H

17

Image 17
Contents Model 288048 Shown Automatic Airless Spray GunsContents Equipment Misuse Hazard Pressurized Equipment Hazard Ventilate Spray Booth InstallationConfigure Gun and Manifold Non-circulating SystemGround System Install Air FittingsReciprocating Arm Rod Mount Mount GunStationary Support Mount All ManifoldsSetup KEY Manifolds 288219Adjust Spray Pattern Install Spray TipAdjust a Streaming Tip Flush Spray GunOperation Pressure Relief ProcedureApply the Fluid IncorrectDaily Gun Care Daily Cleaning Procedure General System MaintenanceDaily Flushing Procedure Perform Pressure Relief Procedure,Problem Cause Solution TroubleshootingGeneral Troubleshooting Problem Cause Solution Spray Pattern Troubleshooting Disassembly ServiceService Notes Reassembly Model Parts11† Ref. only Part No. Description Qty TIP see GG0 Series Tip Selec Tion Charts,Parts North America and International Manifold Description QtyGG0 Series Spray Tips GG0 Series Tip Selection ChartsShower Tip Sealer Application Tip and Air Cap Selection ChartsStreaming Tips Single Orifice Fan Pattern Spray TipsAccessories Dimensions Manifold Mounting Hole Layout Mounting Hole LayoutSound Power Levels dBa Technical DataTriggering Speed Sound Pressure Levels dBaGraco Information Graco Standard Warranty