Graco 230-998, 230-978, 231-015 manual All Models See Fig, Manual Component

Page 7

Installation

NOTES:

DThe reference numbers and letters in parentheses in the text refer to the callouts in the drawings.

DThe accessories mentioned are available from your Graco distributor.

DThe following manuals are supplied with your unit:

Manual Component

307±595 10:1 Ratio Monark Pump

308±640 Air±Assisted Airless

 

Spray Gun

308±167

Air Regulator

307±273

Fluid Filter

307±886

Fluid Regulator (Model 230±978

 

Sprayer only)

WARNING

For your safety in installing, operating, and servic- ing this system, thoroughly read and follow all warnings and instructions given in this manual or in any other manuals supplied with this system or any accessories you add to the system. If a manual is missing or you need additional copies, copies are available from Graco at no charge.

All Models (See Fig 2)

DO NOT install the spray tip in the gun yet.

Install an air line filter (H) in the main air line, to re- move harmful dirt and moisture from the compressed air supply. Install a bleed±type master air valve (J) close to the pump air inlet, and downstream from the pump air regulator (K). Install a second bleed valve (L) upstream from all other accessories, to isolate the accessories for servicing.Connect an air supply hose between the main air supply line and the sprayer's air inlet swivel (1).

CAUTION

To avoid contaminating the air supply to the gun, do not use an automatic air line lubricator; lubricate the motor manually, instead. See OPERATION on page 11.

WARNING

The bleed-type master air valve (J), air relief valve (9), and fluid drain valve (E) are required in your system, to help reduce the risk of serious injury including fluid injection, splashing in the eyes or on the skin, overpressurization, or injury from moving parts if you are adjusting or repairing the pump.

The bleed-type master air valve relieves air trapped between this valve and the pump. Trapped air can cause the pump to cycle unexpectedly.

The air relief valve (supplied) opens automatically to relieve air pressure to the pump if the pressure exceeds a preset level. This valve prevents over- pressurization of the spray gun.

The fluid drain valve assists in relieving fluid pres- sure in the displacement pump, hose, and gun; triggering the gun to relieve pressure may not be sufficient.

307±636 7

Image 7
Contents Model 230±978 Series B 307±636Model 230±998, Series B Model 231±015Symbols Table of Contents 307±636 307±636 Injection HazardFire and Explosion Hazard 307±636 Grounding InstallationManual Component All Models See FigAssembling Sprayer Model 230±978 See Fig Assembling Sprayer Model 231±015 See FigA40 Detail aOperation Pressure Relief Procedure10 307±636 Manual Air Motor Lubrication To Operate the PumpAA2000 Spray Gun Operation Shutdown and Care12 307±636 PartsModel 231±015 Model 230±998, Series BModel 230±978, Series B 14 307±636 Technical DataManual Change Summary Category Data307±636 16 307±636 Graco Standard WarrantyGraco Phone Number ±800±367±4023 Toll Free