Graco Inc 244399, 309291P important safety instructions Barrel Removal, Barrel Installation

Page 29

Barrel Removal

1.Prepare the gun for service, page 24.

2.Carefully loosen the nut (32) from the bracket fluid fitting (13). Pull the tube (14) out of the fitting. Make sure both ferrules and the nut stay with the tube.

3.Loosen the three screws (11).

CAUTION

To avoid damaging the power supply (18), pull the gun barrel straight away from the gun handle. If necessary, gently move the gun barrel from side to side to free it from the gun handle.

4.Hold the gun handle (17) with one hand and pull the barrel (16) straight off the handle. See FIG. 13..

14

32

13

11

16

ti1503a

17

ti1504a

Fig. 13. Barrel Removal

Repair

Barrel Installation

1.Be sure the gasket (10*) is in place. Make sure the air holes are aligned properly. Replace if damaged. See FIG. 14..

2.Place the barrel (16) over the power supply (18) and onto the gun handle (17).

3.Tighten the three screws (11) oppositely and evenly (about a half turn past snug).

CAUTION

Do not over-tighten the screws (11).

4.Assemble the fluid tube (14) into the bracket fitting (13). Ensure that the ferrules are in place. Tighten the nut (32).

5.Test gun resistance, page 17.

*10

18

11

16

ti1535a

Fig. 14. Barrel Installation

309291P

29

Image 29
Contents II 2 G EEx 0.24 mJ PRO Xs2 Air Spray GunModel Information Table of ContentsToxic Fluid Hazard Fire, Explosion, and Electric Shock HazardPressurized Equipment Hazard Equipment Misuse HazardGun Overview IntroductionHow the Electrostatic Spray Gun Works Install the System InstallationVentilate the Spray Booth Flammable or Toxic Vapor HazardKey Typical InstallationConnect the Exhaust Tube Connect the Air LineElectric Shock Hazard Supply HoseOrifice Size Select a Fluid Nozzle and Air CapFilter the Fluid Connect the Fluid LineGrounding Check Gun Grounding Check Electrical GroundingCheck Fluid Viscosity Check Fluid ResistivityOperation Flush the Spray Gun MaintenanceTi1288a Test Gun Resistance Electrical TestsTest Power Supply Resistance Test Power Supply ResistanceElectrode Test Electrode ResistanceProblem Cause Solution TroubleshootingSpray Pattern Troubleshooting Gun Operation Troubleshooting See Test Gun Resistance on Electrical TroubleshootingSee Check Electrical Grounding on 12 and Test Gun ResistanceRepair Pressure Relief ProcedurePrepare the Gun for Service Air Cap/Nozzle Replacement Air Cap/Nozzle Replacement Electrode Replacement Electrode ReplacementFluid Packing Removal Fluid Packing RemovalPacking Rod Packing Rod RepairBarrel Removal Barrel InstallationPower Supply Power Supply Removal and ReplacementTurbine Alternator Removal and Replacement Fan Air Adjustment Valve Fan Air Adjustment Valve RepairAir Valve Repair Fluid Adjustment Valve RepairAtomizing Air Valve Atomizing Air Restrictor Valve Removal and ReplacementES ON/OFF Valve ES ON/OFF Valve RepairPart No 20 kV Electrostatic Gun, Series C PartsRef. No Alternator Qty Part No. Description Part No. DescriptionFluid Line Accessories AccessoriesAir Line Accessories Miscellaneous Accessories Gun AccessoriesCategory Data Technical DataGraco Information Graco Standard Warranty